Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT.

Tinsu Pan1.   

Abstract

We proposed a data sufficiency condition (DSC) for four-dimensional-CT (4D-CT) imaging on a multislice CT scanner, designed a pitch factor for a helical 4D-CT, and compared the acquisition time, slice sensitivity profile (SSP), effective dose, ability to cope with an irregular breathing cycle, and gating technique (retrospective or prospective) of the helical 4D-CT and the cine 4D-CT on the General Electric (GE) LightSpeed RT (4-slice), Plus (4-slice), Ultra (8-slice) and 16 (16-slice) multislice CT scanners. To satisfy the DSC, a helical or cine 4D-CT acquisition has to collect data at each location for the duration of a breathing cycle plus the duration of data acquisition for an image reconstruction. The conditions for the comparison were 20 cm coverage in the cranial-caudal direction, a 4 s breathing cycle, and half-scan reconstruction. We found that the helical 4D-CT has the advantage of a shorter scan time that is 10% shorter than that of the cine 4D-CT, and the disadvantages of 1.8 times broadening of SSP and requires an additional breathing cycle of scanning to ensure an adequate sampling at the start and end locations. The cine 4D-CT has the advantages of maintaining the same SSP as slice collimation (e.g., 8 x 2.5 mm slice collimation generates 2.5 mm SSP in the cine 4D-CT as opposed to 4.5 mm in the helical 4D-CT) and a lower dose by 4% on the 8- and 16-slice systems, and 8% on the 4-slice system. The advantage of faster scanning in the helical 4D-CT will diminish if a repeat scan at the location of a breathing irregularity becomes necessary. The cine 4D-CT performs better than the helical 4D-CT in the repeat scan because it can scan faster and is more dose efficient.

Entities:  

Mesh:

Year:  2005        PMID: 15789609     DOI: 10.1118/1.1855013

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  34 in total

1.  Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: a feasibility study.

Authors:  Jing Cai; Zheng Chang; Zhiheng Wang; William Paul Segars; Fang-Fang Yin
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Thoracic target volume delineation using various maximum-intensity projection computed tomography image sets for radiotherapy treatment planning.

Authors:  David A Zamora; Adam C Riegel; Xiaojun Sun; Peter Balter; George Starkschall; Osama Mawlawi; Tinsu Pan
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

3.  Reconstruction of four-dimensional computed tomography lung images by applying spatial and temporal anatomical constraints using a Bayesian model.

Authors:  Tiancheng He; Zhong Xue; Bin S Teh; Stephen T Wong
Journal:  J Med Imaging (Bellingham)       Date:  2015-05-13

4.  4D-CT motion estimation using deformable image registration and 5D respiratory motion modeling.

Authors:  Deshan Yang; Wei Lu; Daniel A Low; Joseph O Deasy; Andrew J Hope; Issam El Naqa
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

5.  Comparison of image registration based measures of regional lung ventilation from dynamic spiral CT with Xe-CT.

Authors:  Kai Ding; Kunlin Cao; Matthew K Fuld; Kaifang Du; Gary E Christensen; Eric A Hoffman; Joseph M Reinhardt
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

6.  Characterization and identification of spatial artifacts during 4D-CT imaging.

Authors:  Dongfeng Han; John Bayouth; Sudershan Bhatia; Milan Sonka; Xiaodong Wu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

7.  Comparison of breathing gated CT images generated using a 5DCT technique and a commercial clinical protocol in a porcine model.

Authors:  Dylan P O'Connell; David H Thomas; Tai H Dou; James M Lamb; Franklin Feingold; Daniel A Low; Matthew K Fuld; Jered P Sieren; Chelsea M Sloan; Melissa A Shirk; Eric A Hoffman; Christian Hofmann
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

8.  Cine CT for attenuation correction in cardiac PET/CT.

Authors:  Adam M Alessio; Steve Kohlmyer; Kelley Branch; Grace Chen; James Caldwell; Paul Kinahan
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

Review 9.  [Computed tomography of the lungs. A step into the fourth dimension].

Authors:  J Dinkel; C Hintze; N Rochet; C Thieke; J Biederer
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

Review 10.  [Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI].

Authors:  J Biederer; C Hintze; M Fabel; J Dinkel
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.