Ghosting caused by bulk charge trapping in direct conversion flat-panel detectors using amorphous selenium.

Wei Zhao1, G DeCrescenzo, Safa O Kasap, J A Rowlands.   

Abstract

Direct flat-panel detectors using amorphous selenium (a-Se) x-ray photoconductors are gaining wide-spread clinical use. The goal of our investigation is to understand the physical mechanisms responsible for ghosting, i.e., x-ray induced change in sensitivity that results in image persistence, so that the knowledge can be used to consistently minimize ghosting artifacts in a-Se flat-panel detectors. In this paper we will discuss the effect on x-ray sensitivity of charge trapping in a-Se, which is the dominant source for ghosting in a-Se flat-panel detectors. Our approach is to correlate ghosting in electroded a-Se detectors with the trapped charge concentration measured by the "time-of-flight" (TOF) method. All measurements were performed as a function of radiation exposure X of up to approximately 20 R at electric field strength's of E(Se)=5 and 10 V/microm. The results showed that the x-ray sensitivity decreased as a function of X and the amount of ghosting decreased with increasing E(Se). The shape of the TOF curves changed as a result of irradiation in a manner indicating trapped electrons in the bulk of a-Se. The density of trapped electrons n(t) increases as a function of X. A method was developed to determine the values of n(t) in the bulk of a-Se from the TOF measurements, and to predict the corresponding change in x-ray sensitivity. Our results showed that a recombination coefficient consistent with that predicted by Langevin produced good agreement between calculated and measured x-ray sensitivity changes. Thus it can be concluded that the trapping of electrons in the bulk of a-Se and their subsequent recombination with x-ray generated free holes is the dominant mechanism for ghosting in a-Se.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15789596     DOI: 10.1118/1.1843353

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

Review 1.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

2.  Oblique reconstructions in tomosynthesis. II. Super-resolution.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

3.  Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system.

Authors:  Bo Zhao; Wei Zhao
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

4.  A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

5.  Observation of super-resolution in digital breast tomosynthesis.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

6.  Optimization of phosphor-based detector design for oblique x-ray incidence in digital breast tomosynthesis.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

Review 7.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

Review 8.  Amorphous and polycrystalline photoconductors for direct conversion flat panel x-ray image sensors.

Authors:  Safa Kasap; Joel B Frey; George Belev; Olivier Tousignant; Habib Mani; Jonathan Greenspan; Luc Laperriere; Oleksandr Bubon; Alla Reznik; Giovanni DeCrescenzo; Karim S Karim; John A Rowlands
Journal:  Sensors (Basel)       Date:  2011-05-09       Impact factor: 3.576

9.  Evaluation of image lag in a flat-panel, detector-equipped cardiovascular X-ray machine using a newly developed dynamic phantom.

Authors:  Hisaya Sato; Keisuke Kondo; Kyoichi Kato; Yasuo Nakazawa
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.