A fourier analysis of the dose grid resolution required for accurate IMRT fluence map optimization.

James F Dempsey1, H Edwin Romeijn, Jonathan G Li, Daniel A Low, Jatinder R Palta.   

Abstract

We present a theoretical and empirical analysis of the errors associated with the spatial discretization of the dose grid employed in optimized intensity modulated radiation therapy (IMRT) treatment plans. An information theory based Fourier analysis of the accuracy of discrete representations of three-dimensional dose distributions is presented. When applied to beamlet-based IMRT dose distributions, the theory produces analytic integrals that can bound worst case aliasing errors that can occur regardless of the location and orientation of the dose grid. The predictions of this theory are compared to empirical results obtained by solving a linear-programming based fluence-map optimization model to global optimality. A reasonable agreement between worst case estimates and the empirical results is attributed to the fact that the optimization takes advantage of aliasing to produce an optimal plan. We predicted and empirically demonstrated that an isotropic dose grid with <2.5 mm spacing is sufficient to prevent dose errors larger than a percent. However, we noted that in practice this resolution is mostly needed in high-dose target regions. Finally, a multiresolution 2-4-6 mm spacing model was developed and empirically tested where these spacings were applied to targets, structures, and tissue, respectively.

Mesh:

Year:  2005        PMID: 15789583     DOI: 10.1118/1.1843354

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  An MLC calibration method using a detector array.

Authors:  Thomas A Simon; Darren Kahler; William E Simon; Christopher Fox; Jonathan Li; Jatinder Palta; Chihray Liu
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

2.  Novel, full 3D scintillation dosimetry using a static plenoptic camera.

Authors:  Mathieu Goulet; Madison Rilling; Luc Gingras; Sam Beddar; Luc Beaulieu; Louis Archambault
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

3.  Investigating the dosimetric effects of grid size on dose calculation accuracy using volumetric modulated arc therapy in spine stereotactic radiosurgery.

Authors:  Chin Snyder Karen; Manju Liu; Bo Zhao; Yimei Huang; Wen Ning; Indrin J Chetty; M Salim Siddiqui
Journal:  J Radiosurg SBRT       Date:  2017

4.  Optimal set of grid size and angular increment for practical dose calculation using the dynamic conformal arc technique: a systematic evaluation of the dosimetric effects in lung stereotactic body radiation therapy.

Authors:  Ji-Yeon Park; Siyong Kim; Hae-Jin Park; Jeong-Woo Lee; Yeon-Sil Kim; Tae-Suk Suh
Journal:  Radiat Oncol       Date:  2014-01-04       Impact factor: 3.481

5.  Feasibility of using two-dimensional array dosimeter for in vivo dose reconstruction via transit dosimetry.

Authors:  Heeteak Chung; Jonathan Li; Sanjiv Samant
Journal:  J Appl Clin Med Phys       Date:  2011-04-08       Impact factor: 2.102

6.  Single fraction radiosurgery/stereotactic body radiation therapy (SBRT) for spine metastasis: A dosimetric comparison of multiple delivery platforms.

Authors:  Adrian Nalichowski; Isaac Kaufman; John Gallo; Todd Bossenberger; Tim Solberg; Ezequiel Ramirez; Yulong Yan; Julie Fredrick; Tewfik Bichay; Alan Mayville; Jay Burmeister
Journal:  J Appl Clin Med Phys       Date:  2016-12-29       Impact factor: 2.102

7.  Evaluation of a new VMAT QA device, or the "X" and "O" array geometries.

Authors:  Vladimir Feygelman; Geoffrey Zhang; Craig Stevens; Benjamin E Nelms
Journal:  J Appl Clin Med Phys       Date:  2011-01-31       Impact factor: 2.102

8.  Comparative planning of flattening-filter-free and flat beam IMRT for hypopharynx cancer as a function of beam and segment number.

Authors:  Yvonne Dzierma; Frank G Nuesken; Jochen Fleckenstein; Patrick Melchior; Norbert P Licht; Christian Rübe
Journal:  PLoS One       Date:  2014-04-10       Impact factor: 3.240

9.  Comparison of User-Directed and Automatic Mapping of the Planned Isocenter to Treatment Space for Prostate IGRT.

Authors:  Zijie Xu; Ronald Chen; Andrew Wang; Andrea Kress; Mark Foskey; An Qin; Timothy Cullip; Gregg Tracton; Sha Chang; Joel Tepper; Di Yan; Edward Chaney
Journal:  Int J Biomed Imaging       Date:  2013-11-21

10.  Effects of spatial resolution and noise on gamma analysis for IMRT QA.

Authors:  Jessie Y Huang; Kiley B Pulliam; Elizabeth M McKenzie; David S Followill; Stephen F Kry
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.