Literature DB >> 15776195

Influence of casting methods on marginal and internal discrepancies of complete cast crowns.

Fábio Machado Milan1, Simonides Consani, Lourenço Correr Sobrinho, Mario Alexandre Coelho Sinhoreti, Manoel D Sousa-Neto, Jonathan C Knowles.   

Abstract

The relationship between the application of die-spacer prior to wax pattern fabrication and metal removal from the inner surface of the casting on marginal and internal discrepancies of complete cast crowns was evaluated. One hundred and twenty complete crowns were cast with palladium-silver alloy melted by gas-oxygen torch or electrical resistance and cast with a centrifuge casting machine. After casting, the crowns were seated on each type of different marginal configuration dies (90-degree shoulder, 20-degree beveled shoulder, and 45-degree chamfered shoulder) with a static load of 90 N during 1 min. Evaluation of the marginal fit of the specimens was made using a digital micrometer. The crowns were embedded in acrylic resin and longitudinally sectioned to verify the internal discrepancy that occurred in lateral and occlusal interfaces with a digital micrometer. The data were submitted to ANOVA and Tukey's test with a significance level of 5%. The best marginal and inner fits were obtained with the gas-oxygen torch source. The 45-degree chamfered shoulder showed the best marginal and inner fit, and better internal relief was obtained in the crowns abraded with 50 microm Al2O3 particles.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15776195     DOI: 10.1590/s0103-64402004000200008

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  5 in total

1.  Comparative Evaluation of Marginal Accuracy of a Cast Fixed Partial Denture Compared to Soldered Fixed Partial Denture Made of Two Different Base Metal Alloys and Casting Techniques: An In vitro Study.

Authors:  J Brintha Jei; Jayashree Mohan
Journal:  J Indian Prosthodont Soc       Date:  2013-04-17

2.  Comparative Evaluation of Marginal and Internal Gap of Co-Cr Copings Fabricated from Conventional Wax Pattern, 3D Printed Resin Pattern and DMLS Tech: An In Vitro Study.

Authors:  Eswaran Bhaskaran; N S Azhagarasan; Saket Miglani; T Ilango; G Phani Krishna; B Gajapathi
Journal:  J Indian Prosthodont Soc       Date:  2013-05-03

3.  Comparative evaluation of marginal fit and axial wall adaptability of copings fabricated by metal laser sintering and lost-wax technique: An in vitro study.

Authors:  Bhushan Satish Gaikwad; Girish Nazirkar; Rajani Dable; Shailendra Singh
Journal:  J Indian Prosthodont Soc       Date:  2018 Jan-Mar

4.  An Evaluation of the Gap Sizes of 3-Unit Fixed Dental Prostheses Milled from Sintering Metal Blocks.

Authors:  Jae-Kwan Jung
Journal:  Biomed Res Int       Date:  2017-01-29       Impact factor: 3.411

5.  Effect of the Use of Die Lubricant on the Marginal Fit of Wax Patterns.

Authors:  Ajinkya Wagh; Mahesh Gandhewar; Pankaj Pawar; Ashada Chavan; Snehal Kharwade; Anjali Mendhe; Devina Singh
Journal:  J Pharm Bioallied Sci       Date:  2021-11-10
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.