Comparative Evaluation of Marginal Accuracy of a Cast Fixed Partial Denture Compared to Soldered Fixed Partial Denture Made of Two Different Base Metal Alloys and Casting Techniques: An In vitro Study.

J Brintha Jei1, Jayashree Mohan2.   

Abstract

The periodontal health of abutment teeth and the durability of fixed partial denture depends on the marginal adaptation of the prosthesis. Any discrepancy in the marginal area leads to dissolution of luting agent and plaque accumulation. This study was done with the aim of evaluating the accuracy of marginal fit of four unit crown and bridge made up of Ni-Cr and Cr-Co alloys under induction and centrifugal casting. They were compared to cast fixed partial denture (FPD) and soldered FPD. For the purpose of this study a metal model was fabricated. A total of 40 samples (4-unit crown and bridge) were prepared in which 20 Cr-Co samples and 20 Ni-Cr samples were fabricated. Within these 20 samples of each group 10 samples were prepared by induction casting technique and other 10 samples with centrifugal casting technique. The cast FPD samples obtained were seated on the model and the samples were then measured with travelling microscope having precision of 0.001 cm. Sectioning of samples was done between the two pontics and measurements were made, then the soldering was made with torch soldering unit. The marginal discrepancy of soldered samples was measured and all findings were statistically analysed. The results revealed minimal marginal discrepancy with Cr-Co samples when compared to Ni-Cr samples done under induction casting technique. When compared to cast FPD samples, the soldered group showed reduced marginal discrepancy.

Entities:  

Keywords:  Cast fixed partial denture; Centrifugal casting; Chromium–cobalt; Induction casting; Marginal accuracy; Nickel–chromium; Soldered fixed partial denture

Year:  2013        PMID: 24605006      PMCID: PMC3935047          DOI: 10.1007/s13191-013-0286-2

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  19 in total

1.  Influence of melting and casting methods and finish line design on the marginal discrepancy of nickel-chromium-titanium alloy crowns.

Authors:  Pablo G Cogolludo; María J Suarez; Jesús Peláez; José F L Lozano
Journal:  Int J Prosthodont       Date:  2010 Sep-Oct       Impact factor: 1.681

Review 2.  Considerations in measurement of marginal fit.

Authors:  J R Holmes; S C Bayne; G A Holland; W D Sulik
Journal:  J Prosthet Dent       Date:  1989-10       Impact factor: 3.426

3.  Marginal fit and surface roughness of crowns made with an accelerated casting technique.

Authors:  E Konstantoulakis; H Nakajima; R D Woody; A W Miller
Journal:  J Prosthet Dent       Date:  1998-09       Impact factor: 3.426

Review 4.  Soldering in prosthodontics--an overview, part I.

Authors:  Gerard Byrne
Journal:  J Prosthodont       Date:  2011-02-15       Impact factor: 2.752

5.  Clinical applications of multiple unit castings for fixed prostheses.

Authors:  R W Bruce
Journal:  J Prosthet Dent       Date:  1967-10       Impact factor: 3.426

6.  Casting accuracy of a nickel and beryllium-free cobalt-chromium alloy for crown and bridge prostheses and resin-bonded bridges.

Authors:  O Hansson
Journal:  Swed Dent J       Date:  1985

7.  Distortion in dental soldering as affected by gap distance.

Authors:  L M Willis; J I Nicholls
Journal:  J Prosthet Dent       Date:  1980-03       Impact factor: 3.426

8.  Accuracy of one-piece castings, preceramic and postceramic soldering.

Authors:  G J Ziebert; A Hurtado; C Glapa; B E Schiffleger
Journal:  J Prosthet Dent       Date:  1986-03       Impact factor: 3.426

9.  A comparison of the marginal adaptation of cathode-arc vapor-deposited titanium and cast base metal copings.

Authors:  Jean C Wu; Li-Chung Lai; Cherilyn G Sheets; James Earthman; Robert Newcomb
Journal:  J Prosthet Dent       Date:  2011-06       Impact factor: 3.426

10.  Improving the casting accuracy of fixed partial dentures.

Authors:  R W Hinman; J A Tesk; E E Parry; G T Eden
Journal:  J Prosthet Dent       Date:  1985-04       Impact factor: 3.426

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.