BACKGROUND: Magnetic resonance colonography (MRC) with fecal tagging has recently been investigated in clinical studies for the detection of polyps. We assessed fecal tagging MRC in a field trial. METHODS: Forty-two patients in a private gastroenterologic practice underwent MRC with barium-based fecal tagging (150 mL of 100% barium at each of 6 main meals before MRC) and conventional colonoscopy. Diagnostic accuracy of MRC and patient acceptance were assessed and compared with the respective results of conventional colonoscopy. RESULTS: Eighteen percent of all MRC examinations showed a remaining high stool signal in the colon that impeded a reliable inclusion or exclusion of polyps. On a lesion-by-lesion basis, sensitivities for polyp detection were 100% for polyps larger than 2 cm (n = 1), 40% for polyps between 10 and 19 mm, 16.7% for polyps between 6 and 9 mm, and 9.1% for polyps smaller than 6 mm. The main reason for the low acceptance of MRC was the barium preparation, which was rated worse than the bowel cleaning procedure with conventional colonoscopy. CONCLUSION: MRC with fecal tagging must be further optimized. The large amount of barium resulted in poor patient acceptance, and barium according to this protocol did not provide sufficient stool darkening. Other strategies, such as increasing the hydration of stool, must be developed.
BACKGROUND: Magnetic resonance colonography (MRC) with fecal tagging has recently been investigated in clinical studies for the detection of polyps. We assessed fecal tagging MRC in a field trial. METHODS: Forty-two patients in a private gastroenterologic practice underwent MRC with barium-based fecal tagging (150 mL of 100% barium at each of 6 main meals before MRC) and conventional colonoscopy. Diagnostic accuracy of MRC and patient acceptance were assessed and compared with the respective results of conventional colonoscopy. RESULTS: Eighteen percent of all MRC examinations showed a remaining high stool signal in the colon that impeded a reliable inclusion or exclusion of polyps. On a lesion-by-lesion basis, sensitivities for polyp detection were 100% for polyps larger than 2 cm (n = 1), 40% for polyps between 10 and 19 mm, 16.7% for polyps between 6 and 9 mm, and 9.1% for polyps smaller than 6 mm. The main reason for the low acceptance of MRC was the barium preparation, which was rated worse than the bowel cleaning procedure with conventional colonoscopy. CONCLUSION: MRC with fecal tagging must be further optimized. The large amount of barium resulted in poor patient acceptance, and barium according to this protocol did not provide sufficient stool darkening. Other strategies, such as increasing the hydration of stool, must be developed.
Authors: Otto S Lin; Richard A Kozarek; Michael Gluck; Geoffrey C Jiranek; Johannes Koch; Kris V Kowdley; Shayan Irani; Matthew Nguyen; Jason A Dominitz Journal: J Gen Intern Med Date: 2012-06-15 Impact factor: 5.128
Authors: Sonja Kinner; Christiane A Kuehle; Jost Langhorst; Susanne C Ladd; Michael Nuefer; Thomas Zoepf; Joerg Barkhausen; Guido Gerken; Thomas C Lauenstein Journal: Eur Radiol Date: 2007-05-24 Impact factor: 5.315
Authors: C Chad Quarles; Martin Lepage; D Lee Gorden; Barbara Fingleton; Thomas E Yankeelov; Ronald R Price; Lynn M Matrisian; John C Gore; J Oliver McIntyre Journal: Magn Reson Med Date: 2008-09 Impact factor: 4.668