Literature DB >> 15745293

End-stage heart failure with multiple intracardiac thrombi: a rescue strategy.

Maximillian G Posch1, Larry O Thompson, Michael M Koerner, Mehmet H Akay, George P Noon, Matthias Loebe.   

Abstract

The use of ventricular assist devices as a bridge to transplantation has become a widely used option for patients with end-stage heart failure. In contrast to total artificial hearts, ventricular assist devices support the failing heart by bypassing one or both ventricles. In certain cases (myocardial tumors, graft failure, transplant rejection, endocarditis, intracardiac thrombus formation), however, it may be advantageous to excise the heart and replace it with an artificial device. Total artificial hearts are intracorporeal devices designed for this purpose. Unfortunately, some patients are too small or are, for other reasons, ineligible for a total artificial heart. We describe the case of a 55-year-old woman who had ischemic cardiomyopathy and thrombus formation in all 4 cardiac chambers. To reduce the risk of thromboembolic events, we elected to replace her heart completely with 2 extracorporeal ventricular assist devices. The heart was excised via a median stemotomy approach, and the outflow cannulae (from device to patient) were connected to both atrial remnants. The 2 inflow cannulae (from patient to device) were anastomosed end-to-end to the aorta and the pulmonary artery, respectively. After attaining a flow of more than 5 L, the 2 extracorporeal assist devices effectively and efficiently performed the work of the native heart. Thus re-established, organ perfusion was improved by this mechanically driven circulation, as signified by an initial decrease in creatinine and blood urea nitrogen levels. The patient, however, did not recover from postoperative neurological dysfunction and died of respiratory insufficiency and multiple-organ failure on the 26th postoperative day.

Entities:  

Mesh:

Year:  2004        PMID: 15745293      PMCID: PMC548242     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  9 in total

1.  Long-term use of a left ventricular assist device for end-stage heart failure.

Authors:  E A Rose; A C Gelijns; A J Moskowitz; D F Heitjan; L W Stevenson; W Dembitsky; J W Long; D D Ascheim; A R Tierney; R G Levitan; J T Watson; P Meier; N S Ronan; P A Shapiro; R M Lazar; L W Miller; L Gupta; O H Frazier; P Desvigne-Nickens; M C Oz; V L Poirier
Journal:  N Engl J Med       Date:  2001-11-15       Impact factor: 91.245

2.  Implantation of biventricular assist devices for chronic heart transplant rejection.

Authors:  Akira Sezai; Latif Arusoglu; Kazutomo Minami; Aly El-Banayosy; Reiner Körfer
Journal:  Ann Thorac Surg       Date:  2002-08       Impact factor: 4.330

3.  An uncommon complication of Behçet's disease: intracardiac thrombosis needing surgical treatment.

Authors:  K Kirali; A Civelek; B Dağlar; M Sişmanoğlu; E Akinci; T Berki; O Işik; C Yakut
Journal:  Thorac Cardiovasc Surg       Date:  1998-04       Impact factor: 1.827

4.  Successful implantation of Thoratec assist device: wrapping of outflow conduit in Hemashield graft.

Authors:  K Minami; L Arusoglu; T Koyanagi; A el-Banayosy; M M Körner; R Körfer
Journal:  Ann Thorac Surg       Date:  1997-09       Impact factor: 4.330

5.  Successful lysis of right and left heart thrombus by tissue plasminogen activator.

Authors:  K H Yeh; K C Hung; F C Lin; S J Yeh; D Wu
Journal:  Catheter Cardiovasc Interv       Date:  2000-01       Impact factor: 2.692

6.  Comparison of the CardioWest total artificial heart, the novacor left ventricular assist system and the thoratec ventricular assist system in bridge to transplantation.

Authors:  J G Copeland; R G Smith; F A Arabia; P E Nolan; V K Mehta; M S McCarthy; K A Chisholm
Journal:  Ann Thorac Surg       Date:  2001-03       Impact factor: 4.330

Review 7.  Successful use of tissue plasminogen activator in catheter-related intracardiac thrombus of a premature infant.

Authors:  M J Torres-Valdivieso; J Cobas; C Barrio; C Muñoz; M Pascual; C Orbea; E Rodriguez; F Gutiérrez
Journal:  Am J Perinatol       Date:  2003-02       Impact factor: 1.862

Review 8.  Success rates of long-term circulatory assist devices used currently for bridge to heart transplantation.

Authors:  F A Arabia; R G Smith; D S Rose; D A Arzouman; G K Sethi; J G Copeland
Journal:  ASAIO J       Date:  1996 Sep-Oct       Impact factor: 2.872

9.  Mechanical circulatory support after orthotopic heart transplantation.

Authors:  G Tenderich; M M Koerner; B Stuettgen; K Minami; A El-Banayosy; L Arusoglu; N Mirow; S Wlost; H Gromzik; K Kleesiek; H Meyer; R Koerfer
Journal:  Int J Artif Organs       Date:  1998-07       Impact factor: 1.595

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.