Optimum control of the Hemopump as a left-ventricular assist device.

P He1, J Bai, D D Xia.   

Abstract

A general framework for designing an optimum control strategy for the Hemopump is described. An objective function was defined that includes four membership functions, each constructed based on the desired values of one of the four members: stroke volume, mean left atrial pressure, aortic diastolic pressure and mean pump rotation speed. The Hemopump was allowed to operate either at a constant speed or at two different speeds during a cardiac cycle. The goal was to maximise the objective function by varying the magnitude and timing of the pump speed. Using a canine circulatory model, it was demonstrated that, in general, different cardiac conditions or different clinical objectives require different operation parameters. For example, when a left ventricle with minor ischaemia was simulated, and the main objective was to increase stoke volume, the objective function was maximised, from a value of 0.877 when the pump was off, to 0.946 when the pump was operated at speed 2 (18 500 revolutions min(-1)). On the other hand, for a severely ischaemic heart, the optimum pump speed became speed 3 (20 000 revolutions min(-1)), which maximized the objective function to 0.943 (from 0.707 when the pump was off). The results also suggest that it is more beneficial to operate the Hemopump at two different speeds during a cardiac cycle (a higher speed during systole and early diastole, and a lower speed during late diastole) than to maintain a constant speed throughout the cardiac cycle.

Entities:  

Mesh:

Year:  2005        PMID: 15742732     DOI: 10.1007/bf02345135

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  Simulation study of the Hemopump as a cardiac assist device.

Authors:  X Li; J Bai; P He
Journal:  Med Biol Eng Comput       Date:  2002-05       Impact factor: 2.602

2.  An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse.

Authors:  Yi Wu; Paul Allaire; Gang Tao; Houston Wood; Don Olsen; Curt Tribble
Journal:  Artif Organs       Date:  2003-10       Impact factor: 3.094

3.  Hemodynamic system analysis of intraarterial microaxial pumps in vitro and in vivo.

Authors:  T Siess; B Meyns; K Spielvogel; H Reul; G Rau; W Flameng
Journal:  Artif Organs       Date:  1996-06       Impact factor: 3.094

4.  The heart-Hemopump interaction: a study of Hemopump flow as a function of cardiac activity.

Authors:  B Meyns; T Siess; S Laycock; H Reul; G Rau; W Flameng
Journal:  Artif Organs       Date:  1996-06       Impact factor: 3.094

5.  Prolonged nonpulsatile left heart bypass with reduced systemic pulse pressure causes morphological changes in the aortic wall.

Authors:  T Nishimura; E Tatsumi; S Takaichi; Y Taenaka; Y Wakisaka; T Nakatani; T Masuzawa; Y Takewa; M Nakamura; S Endo; M Nakata; H Takano
Journal:  Artif Organs       Date:  1998-05       Impact factor: 3.094

Review 6.  Left ventricular assist devices: current status and future applications.

Authors:  J Parameshwar; J Wallwork
Journal:  Int J Cardiol       Date:  1997-12-01       Impact factor: 4.164

Review 7.  Axial flow blood pumps.

Authors:  Xinwei Song; Amy L Throckmorton; Alexandrina Untaroiu; Sonna Patel; Paul E Allaire; Houston G Wood; Don B Olsen
Journal:  ASAIO J       Date:  2003 Jul-Aug       Impact factor: 2.872

8.  The Jarvik 2000 Heart. Clinical validation of the intraventricular position.

Authors:  Stephen Westaby; O H Frazier; Friedhelm Beyersdorf; Satoshi Saito; Michael P Siegenthaler; David W Pigott; Pedro A Catarino; Robert Jarvik
Journal:  Eur J Cardiothorac Surg       Date:  2002-08       Impact factor: 4.191

9.  Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support.

Authors:  Stefan Klotz; Mario C Deng; Joerg Stypmann; Juergen Roetker; Markus J Wilhelm; Dieter Hammel; Hans H Scheld; Christof Schmid
Journal:  Ann Thorac Surg       Date:  2004-01       Impact factor: 4.330

Review 10.  HeartMate implantable left ventricular assist device: bridge to transplantation and future applications.

Authors:  P M McCarthy
Journal:  Ann Thorac Surg       Date:  1995-02       Impact factor: 4.330

View more
  3 in total

1.  Computational modelling and evaluation of cardiovascular response under pulsatile impeller pump support.

Authors:  Yubing Shi; Alistair G Brown; Patricia V Lawford; Andreas Arndt; Peter Nuesser; D Rodney Hose
Journal:  Interface Focus       Date:  2011-03-02       Impact factor: 3.906

2.  Durability improvement of polymer chamber of pulsatile extracorporeal life support system in terms of mechanical change.

Authors:  Hyuk Choi; Seung Hoon Paik; Kwang Ho Lee; Byoung Goo Min; Yong Soon Won
Journal:  Med Biol Eng Comput       Date:  2007-08-25       Impact factor: 3.079

Review 3.  Review of zero-D and 1-D models of blood flow in the cardiovascular system.

Authors:  Yubing Shi; Patricia Lawford; Rodney Hose
Journal:  Biomed Eng Online       Date:  2011-04-26       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.