The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in Spo2 calculation.

Kirk H Shelley1, Doris Tamai, Denis Jablonka, Michael Gesquiere, Robert G Stout, David G Silverman.   

Abstract

Reflective forehead pulse oximeter sensors have recently been introduced into clinical practice. They reportedly have the advantage of faster response times and immunity to the effects of vasoconstriction. Of concern are reports of signal instability and erroneously low Spo(2) values with some of these new sensors. During a study of the plethysmographic wave forms from various sites (finger, ear, and forehead) it was noted that in some cases the forehead wave form became unexpectedly complex in configuration. The plethysmographic signals from 25 general anesthetic cases were obtained, which revealed the complex forehead wave form during 5 cases. We hypothesized that the complex wave form was attributable to an underlying venous signal. It was determined that the use of a pressure dressing over the sensor resulted in a return of a normal plethysmographic wave form. Further examination of the complex forehead wave form reveal a morphology consistent with a central venous trace with atrial, cuspidal, and venous waves. It is speculated that the presence of the venous signal is the source of the problems reported with the forehead sensors. It is believed that the venous wave form is a result of the method of attachment rather than the use of reflective plethysmographic sensors.

Mesh:

Substances:

Year:  2005        PMID: 15728063     DOI: 10.1213/01.ANE.0000145063.01043.4B

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  17 in total

1.  Measuring venous oxygenation using the photoplethysmograph waveform.

Authors:  Zachary D Walton; Panayiotis A Kyriacou; David G Silverman; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2010-07-20       Impact factor: 2.502

2.  The use of joint time frequency analysis to quantify the effect of ventilation on the pulse oximeter waveform.

Authors:  Kirk H Shelley; Aymen A Awad; Robert G Stout; David G Silverman
Journal:  J Clin Monit Comput       Date:  2006-06-01       Impact factor: 2.502

3.  Using the morphology of photoplethysmogram peaks to detect changes in posture.

Authors:  Stephen P Linder; Suzanne M Wendelken; Edward Wei; Susan P McGrath
Journal:  J Clin Monit Comput       Date:  2006-05-11       Impact factor: 2.502

4.  Impact of withdrawal of 450 ml of blood on respiration-induced oscillations of the ear plethysmographic waveform.

Authors:  Michael J Gesquiere; Aymen A Awad; David G Silverman; Robert G Stout; Denis H Jablonka; Tyler J Silverman; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2007-08-16       Impact factor: 2.502

Review 5.  Is pulse oximetry an essential tool or just another distraction? The role of the pulse oximeter in modern anesthesia care.

Authors:  Amit Shah; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2013-01-12       Impact factor: 2.502

6.  Optical oximetry of volume-oscillating vascular compartments: contributions from oscillatory blood flow.

Authors:  Jana M Kainerstorfer; Angelo Sassaroli; Sergio Fantini
Journal:  J Biomed Opt       Date:  2016-10       Impact factor: 3.170

7.  A comparison of finger and forehead pulse oximeters in heart failure patients during maximal exercise.

Authors:  Kevin L Kelly; Alex R Carlson; Thomas G Allison; Bruce D Johnson
Journal:  Heart Lung       Date:  2019-11-14       Impact factor: 2.210

8.  Robust Sensing of Distal Pulse Waveforms on a Modified Weighing Scale for Ubiquitous Pulse Transit Time Measurement.

Authors:  Andrew M Carek; Omer T Inan
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2017-05-23       Impact factor: 3.833

9.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

10.  Forehead reflectance oximetry: a clinical comparison with conventional digit sensors during laparotomic and laparoscopic abdominal surgery.

Authors:  Andrea Casati; Grazia Squicciarini; Marco Baciarello; Marta Putzu; Alessandra Salvadori; Guido Fanelli
Journal:  J Clin Monit Comput       Date:  2007-08-16       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.