Literature DB >> 1572028

Lack of myocardial perfusion immediately after successful thrombolysis. A predictor of poor recovery of left ventricular function in anterior myocardial infarction.

H Ito1, T Tomooka, N Sakai, H Yu, Y Higashino, K Fujii, T Masuyama, A Kitabatake, T Minamino.   

Abstract

BACKGROUND: We investigated myocardial perfusion dynamics after thrombolysis and its clinical implications. METHODS AND
RESULTS: We studied 39 patients with acute anterior myocardial infarction (AMI). Myocardial contrast echocardiography (MCE) was performed before and immediately after successful reflow with intracoronary injection of sonicated Ioxaglate. The average segmental score by two-dimensional echocardiography (graded 0, normal, to 3, akinetic/dyskinetic) and global ejection fraction (left ventricular ejection fraction, LVEF%) by left ventriculography were measured at 1 day and at 4 weeks after reflow. Hypokinesis in the infarct region was assessed by the centerline method and expressed in terms of standard deviations (regional wall motion [RWM]: SD/chord) of normal. Immediately after reflow, 30 of 39 patients (group A) showed significant contrast enhancement within the risk area. The other nine patients (23%, group B), however, showed the residual contrast defect in the risk area (myocardial no reflow). There were no significant differences in the elapsed time, angiographic collateral grade, and degree of residual stenosis between group A and group B. Before reflow, both groups exhibited similar levels of global and regional left ventricular function. Improvement in global (LVEF, average segmental score) and regional left ventricular function was greater in group A than in group B (average segmental score, 0.44 +/- 0.41 versus 0.97 +/- 0.36, p less than 0.01; LVEF, 56.4 +/- 13.4 versus 42.7 +/- 8.9, p less than 0.05; RWM, -1.87 +/- 0.85 versus -3.18 +/- 0.52, p less than 0.005).
CONCLUSIONS: MCE demonstrates that angiographically successful reflow cannot be used as an indicator of successful myocardial reperfusion in AMI patients. The residual contrast defect in the risk area demonstrated immediately after reflow is a predictor of poor functional recovery of the postischemic myocardium.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1572028     DOI: 10.1161/01.cir.85.5.1699

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  153 in total

1.  Enhancing Thrombolysis with Adjunctive Therapy.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1996       Impact factor: 2.300

2.  Achieving Optimal Reperfusion without Adjunctive Antithrombotic Therapy: Novel Thrombolytic Dosing Strategies.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1995       Impact factor: 2.300

3.  The Open Artery Hypothesis: Past, Present, and Future.

Authors:  M Goel; J T Dodge; M Rizzo; C McLean; K A Ryan; W L Daley; C P Cannon; C M Gibson
Journal:  J Thromb Thrombolysis       Date:  1998-05       Impact factor: 2.300

Review 4.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 5.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 6.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 7.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

8.  Reperfusion Injury: Does It Exist and Does It Have Clinical Relevance?

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1997-01       Impact factor: 2.300

9.  Reperfusion Injury in Humans: Existence, Clinical Relevance, Mechanistic Insights, and Potential Therapy.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1997-01       Impact factor: 2.300

Review 10.  Added value of contrast echocardiography in assessing myocardial viability.

Authors:  A Nagy; F L Dini; D Rovai
Journal:  Heart       Date:  1999-11       Impact factor: 5.994

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.