Literature DB >> 1571165

Three-dimensional echocardiographic volume computation by polyhedral surface reconstruction: in vitro validation and comparison to magnetic resonance imaging.

A S Gopal1, D L King, J Katz, L M Boxt, D L King, M Y Shao.   

Abstract

Two-dimensional echocardiographic methods of left ventricular volume computation are limited by geometric assumptions and image plane positioning error in the nonvisualized dimension. We evaluated a three-dimensional (3D echocardiographic method that addresses these limitations. Our method uses a volume computation algorithm based on polyhedral surface reconstruction (PSR) and nonparallel, unequally spaced, nonintersecting short-axis planes. Seventeen balloon phantoms were subjected to volume computation by the 3D echocardiography-PSR method and by magnetic resonance imaging (MRI) and compared to true volumes determined by water displacement. The results for 3D echocardiography-PSR were: accuracy = 2.27%, interobserver variability = 4.33%, r = 0.999, SEE = 2.45 ml, and p less than 0.001. Results for MRI were 8.01%, 13.78%, r = 0.995, SEE = 7.01 ml, and p less than 0.001. There was no statistically significant difference between the methods. We conclude that precise image plane positioning and use of the 3D echocardiographic-PSR volume computation method achieves high accuracy and reproducibility in vitro. The excellent in vitro correlation between 3D echocardiography-PSR and MRI indicates that MRI may also serve as an in vivo standard of comparison.

Entities:  

Mesh:

Year:  1992        PMID: 1571165     DOI: 10.1016/s0894-7317(14)80541-5

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  7 in total

1.  Three-dimensional echocardiographic measurement of left and right ventricular mass and volume: in vitro validation.

Authors:  Michal Hubka; Edward L Bolson; John A McDonald; Roy W Martin; Brad Munt; Florence H Sheehan
Journal:  Int J Cardiovasc Imaging       Date:  2002-04       Impact factor: 2.357

Review 2.  Left ventricular assessment using real time three dimensional echocardiography.

Authors:  L Sugeng; L Weinert; R M Lang
Journal:  Heart       Date:  2003-11       Impact factor: 5.994

3.  Left ventricular volumes assessed by different new three-dimensional echocardiographic methods and ordinary biplane technique.

Authors:  O Rodevand; R Bjornerheim; S Aakhus; J Kjekshus
Journal:  Int J Card Imaging       Date:  1998-02

4.  In vitro validation of right ventricular volume measurement by three dimensional echocardiography.

Authors:  M Vogel; P A White; A N Redington
Journal:  Br Heart J       Date:  1995-10

5.  The effect of erythropoietin on exercise capacity, left ventricular remodeling, pressure-volume relationships, and quality of life in older patients with anemia and heart failure with preserved ejection fraction.

Authors:  Rose S Cohen; Paula Karlin; Madeline Yushak; Donna Mancini; Mathew S Maurer
Journal:  Congest Heart Fail       Date:  2010 May-Jun

Review 6.  Single photon emission computed tomography: an alternative imaging modality in left ventricular evaluation.

Authors:  Hulya Yalçin; Sofiane Maza; Fatih Yalçin
Journal:  Vasc Health Risk Manag       Date:  2008

Review 7.  Assessment of left ventricular function by three-dimensional echocardiography.

Authors:  Boudewijn J Krenning; Marco M Voormolen; Jos R T C Roelandt
Journal:  Cardiovasc Ultrasound       Date:  2003-09-08       Impact factor: 2.062

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.