Literature DB >> 7488465

In vitro validation of right ventricular volume measurement by three dimensional echocardiography.

M Vogel1, P A White, A N Redington.   

Abstract

OBJECTIVE: Evaluation of ability of three dimensional echocardiography to accurately assess right ventricular volumes in vitro.
METHODS: Silicone casts of normal human right ventricles were examined. Each was filled with three different volumes of water to yield 15 different measurements. The casts were examined in a waterbath with three dimensional echocardiography using a 7.5 MHz ultrasound probe mounted in a scan frame. It was steered by a stepper motor, which moved the probe in steps of 0.25 mm over a distance of 5.9 cm inside the frame, acquiring an image at each step. 236 parallel slices of the cast were thus obtained, forming the three dimensional dataset. The longest axis of the right ventricular volume was defined and the area of perpendicular 1 mm thick slices was outlined manually to calculate the area of each slice. This was multiplied by the slice thickness to obtain the volume of each slice; the respective volumes were added to obtain the volume of the whole cast.
RESULTS: The casts had a median volume of 31.1 (23) ml (range 15-100); three dimensional echocardiography gave a median volume of 29.0 (21.7) ml (15.7-91.7). Interobserver variability was 4.5% (0.4%-13.6%) and intraobserver variability 4.3% (0.2%-9.3%). Correlation between real cast volumes and volumes measured by three dimensional echocardiography was 0.99 (y = 1.08 x -0.16) with an SEE of 2.7 ml. Limits for agreement between methods ranged from -3.1 ml to 8.3 ml. In 14 of the 15 measurements, volume by three dimensional echocardiography was smaller than real volume, with the mean difference being 7.4% (2.8%-19.5%). This may be due to the thickening of surfaces of structures when imaged by ultrasonography.
CONCLUSION: Right ventricular volumes can accurately be determined by three dimensional echocardiography.

Entities:  

Mesh:

Year:  1995        PMID: 7488465      PMCID: PMC484057          DOI: 10.1136/hrt.74.4.460

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  14 in total

1.  Right ventricular volume in congenital heart disease.

Authors:  A Benchimol; K B Desser; A R Hastreiter
Journal:  Am J Cardiol       Date:  1975-07       Impact factor: 2.778

2.  Transthoracic real-time three-dimensional echocardiography using the rotational scanning approach for data acquisition.

Authors:  A Ludomirsky; R Vermilion; J Nesser; G Marx; M Vogel; R Derman; N Pandian
Journal:  Echocardiography       Date:  1994-11       Impact factor: 1.724

3.  Three-dimensional echocardiographic volume computation by polyhedral surface reconstruction: in vitro validation and comparison to magnetic resonance imaging.

Authors:  A S Gopal; D L King; J Katz; L M Boxt; D L King; M Y Shao
Journal:  J Am Soc Echocardiogr       Date:  1992 Mar-Apr       Impact factor: 5.251

4.  Measurement of left ventricular ejection fraction and volumes with three-dimensional reconstructed transesophageal ultrasound scans: comparison to radionuclide and thermal dilution measurements.

Authors:  R W Martin; M M Graham; R Kao; G Bashein
Journal:  J Cardiothorac Anesth       Date:  1989-06

5.  Right ventricular volume determinations in children. Normal values and observations with volume or pressure overload.

Authors:  T P Graham; J M Jarmakani; G F Atwood; R V Canent
Journal:  Circulation       Date:  1973-01       Impact factor: 29.690

6.  Angiographic method for volume estimation of right and left ventricles.

Authors:  R A Arcilla; P Tsai; O Thilenius; K Ranniger
Journal:  Chest       Date:  1971-11       Impact factor: 9.410

7.  Evaluation of right ventricular volume and ejection fraction in children by two-dimensional echocardiography.

Authors:  N H Silverman; S Hudson
Journal:  Pediatr Cardiol       Date:  1983 Jul-Sep       Impact factor: 1.655

8.  Echocardiographic measurement of right ventricular volume.

Authors:  R A Levine; T C Gibson; T Aretz; L D Gillam; D E Guyer; M E King; A E Weyman
Journal:  Circulation       Date:  1984-03       Impact factor: 29.690

9.  Tissue mimicking materials for ultrasound phantoms.

Authors:  E L Madsen; J A Zagzebski; R A Banjavie; R E Jutila
Journal:  Med Phys       Date:  1978 Sep-Oct       Impact factor: 4.071

10.  A new three-dimensional echocardiographic method of right ventricular volume measurement: in vitro validation.

Authors:  D T Linker; W E Moritz; A S Pearlman
Journal:  J Am Coll Cardiol       Date:  1986-07       Impact factor: 24.094

View more
  8 in total

1.  Estimation of the right ventricular volume and ejection fraction by transthoracic three-dimensional echocardiography. A validation study using magnetic resonance imaging.

Authors:  S Fujimoto; R Mizuno; Y Nakagawa; K Dohi; H Nakano
Journal:  Int J Card Imaging       Date:  1998-12

Review 2.  Left ventricular assessment using real time three dimensional echocardiography.

Authors:  L Sugeng; L Weinert; R M Lang
Journal:  Heart       Date:  2003-11       Impact factor: 5.994

3.  Comparison of transthoracic three dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass.

Authors:  M Vogel; M Gutberlet; S Dittrich; N Hosten; P E Lange
Journal:  Heart       Date:  1997-08       Impact factor: 5.994

Review 4.  The right ventricle in congenital heart disease.

Authors:  P A Davlouros; K Niwa; G Webb; M A Gatzoulis
Journal:  Heart       Date:  2006-04       Impact factor: 5.994

5.  Assessment of right ventricular function by real-time three-dimensional echocardiography improves accuracy and decreases interobserver variability compared with conventional two-dimensional views.

Authors:  Sarah Chua; Robert A Levine; Chaim Yosefy; Mark D Handschumacher; John Chu; Anwer Qureshi; Jennifer Neary; Thanh-Thao Ton-Nu; Morgan Fu; Chiung Jen Wu; Judy Hung
Journal:  Eur J Echocardiogr       Date:  2009-03-02

6.  Relation between right ventricular enlargement, QRS duration, and right ventricular function in patients with tetralogy of Fallot and pulmonary regurgitation after surgical repair.

Authors:  M Y Abd El Rahman; H Abdul-Khaliq; M Vogel; V Alexi-Meskishvili; M Gutberlet; P E Lange
Journal:  Heart       Date:  2000-10       Impact factor: 5.994

7.  An echocardiographic and magnetic resonance imaging comparative study of right ventricular volume determination.

Authors:  N Aebischer; R Meuli; X Jeanrenaud; J Koerfer; L Kappenberger
Journal:  Int J Card Imaging       Date:  1998-08

8.  Rapid and accurate quantification of right ventricular volume and stroke volume by real-time 3-dimensional triplane echocardiography.

Authors:  Ya-Ni Liu; You-Bin Deng; Bing-Bing Liu; Qing-Yang Zhang
Journal:  Clin Cardiol       Date:  2008-08       Impact factor: 2.882

  8 in total