Literature DB >> 15710013

Nitrous oxide diffusion into the cuffs of disposable laryngeal mask airways.

P Maino1, A Dullenkopf, V Bernet, M Weiss.   

Abstract

The aim of this study was to investigate cuff pressure changes found in disposable size 3 laryngeal mask airways (LMAs) from different manufacturers during nitrous oxide exposure and to compare the results with the re-usable Classic LMA. In an in vitro experiment, laryngeal mask airway cuff pressures starting from a baseline pressure of 40 cm H(2)O were recorded using a pressure transducer for 60 min with the laryngeal mask airway cuff exposed to 66% N(2)O in oxygen. Cuff pressure increases within 5 min of nitrous oxide exposure were > 250% in the Classic LMA and were not significantly different from those found in the Marshall laryngeal mask airway. However, they were significantly greater than those in the Soft Seal, the Unique, the AMBU, and Intersurgical laryngeal mask airways, all of which demonstrated stable cuff pressure levels within the first 5 min. The cuff pressure increase following 60 min of nitrous oxide exposure was 13.0 +/- 1.1 and 14.6 +/- 0.7 cm H(2)O in the Intersurgical and Unique laryngeal mask airways, respectively, which was significantly lower than the cuff pressure increase in the Soft Seal and in the Ambu laryngeal mask airways (28.3 +/- 2.9 and 30.9 +/- 1.2 cm H(2)O, respectively). Unlike the re-usable Classic LMA and the disposable Marshall laryngeal mask airway, which have silicone cuffs, the disposable Ambu, Intersurgical, Portex Soft Seal and Unique laryngeal mask airways have cuffs constructed from PVC, which seems to be less susceptible to hyperinflation caused by nitrous oxide diffusion.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15710013     DOI: 10.1111/j.1365-2044.2004.04072.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  13 in total

1.  Using the inflating syringe as a safety valve to limit laryngeal mask airway cuff pressure.

Authors:  Mark J Rice; Nikolaus L Gravenstein; Sorin J Brull; Timothy E Morey; Nikolaus Gravenstein
Journal:  J Clin Monit Comput       Date:  2011-11-11       Impact factor: 2.502

2.  [Comparison of two different laryngeal mask models for airway management in patients with immobilization of the cervical spine].

Authors:  C Gernoth; O Jandewerth; M Contzen; J Hinkelbein; H Genzwürker
Journal:  Anaesthesist       Date:  2006-03       Impact factor: 1.041

Review 3.  [Laryngeal masks. Possibilities and limits].

Authors:  H Hillebrand; J Motsch
Journal:  Anaesthesist       Date:  2007-06       Impact factor: 1.041

4.  Comparison of Size 2 LMA-ProSeal™ and LMA-Supreme™ in Spontaneously Breathing Children: a Randomised Clinical Trial.

Authors:  Zehra İpek Arslan; Canan Balcı; Duygu Akalın Oysu; Mehmet Yılmaz; Necla Gürbüz; Zekeriya Ilce
Journal:  Balkan Med J       Date:  2013-03-01       Impact factor: 2.021

5.  [Clinical evaluation of a pressure release valve for paediatric cuffed tracheal tubes].

Authors:  S Fertl; V Bernet; A Schmitz; K Woitzek; M Weiss
Journal:  Anaesthesist       Date:  2009-01       Impact factor: 1.041

6.  Damage to the cuff of EMG tube at endotracheal intubation by using a lightwand -A case report-.

Authors:  Hyun-Sook Kim; Keun-Suk Park; Mae-Hwa Kang; Chong Doo Park
Journal:  Korean J Anesthesiol       Date:  2010-12-31

7.  Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults.

Authors:  Daryl Lindsay Williams; James M Zeng; Karl D Alexander; David T Andrews
Journal:  Anesthesiol Res Pract       Date:  2012-02-29

Review 8.  Conservative management of a major post-intubation tracheal injury and review of current management.

Authors:  Geoffrey P J Mullan; Christos Georgalas; Asit Arora; Anthony Narula
Journal:  Eur Arch Otorhinolaryngol       Date:  2007-03-23       Impact factor: 3.236

9.  Unilateral hypoglossal nerve palsy after use of the laryngeal mask airway supreme.

Authors:  Kenichi Takahoko; Hajime Iwasaki; Tomoki Sasakawa; Akihiro Suzuki; Hideki Matsumoto; Hiroshi Iwasaki
Journal:  Case Rep Anesthesiol       Date:  2014-08-31

10.  Comparison of effects of ProSeal LMA™ laryngeal mask airway cuff inflation with air, oxygen, air:oxygen mixture and oxygen:nitrous oxide mixture in adults: A randomised, double-blind study.

Authors:  Mona Sharma; Renu Sinha; Anjan Trikha; Rashmi Ramachandran; C Chandralekha
Journal:  Indian J Anaesth       Date:  2016-08
View more