Literature DB >> 15705513

Numerical simulation of PRESS localized MR spectroscopy.

Andrew A Maudsley1, Varanavasi Govindaraju, Karl Young, Zakaria K Aygula, Pradip M Pattany, Brian J Soher, Gerald B Matson.   

Abstract

Numerical simulations of NMR spectra can provide a rapid and convenient method for optimizing acquisition sequence parameters and generating prior spectral information required for parametric spectral analysis. For spatially resolved spectroscopy, spatially dependent variables affect the resultant spectral amplitudes and phases, which must therefore be taken into account in any spectral simulation model. In this study, methods for numerical simulation of spectra obtained using the PRESS localization pulse sequence are examined. A comparison is made between three different simulation models that include different levels of detail regarding the spatial distributions of the excitation functions, and spin evolution during application of the pulses. These methods were evaluated for measurement of spectra from J-coupled spin systems that are of interest for in vivo proton spectroscopy and results compared with experimental data. It is demonstrated that for optimized refocusing pulses it is sufficient to account for chemical shift effects only, although there is some advantage to implementing a more general numerical simulation approach that includes information on RF pulse excitation profiles, which provides sufficient accuracy while maintaining moderate computational requirements and flexibility to handle different spin systems.

Mesh:

Substances:

Year:  2005        PMID: 15705513     DOI: 10.1016/j.jmr.2004.11.018

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  19 in total

1.  Pitfalls in lactate measurements at 3T.

Authors:  T Lange; U Dydak; T P L Roberts; H A Rowley; M Bjeljac; P Boesiger
Journal:  AJNR Am J Neuroradiol       Date:  2006-04       Impact factor: 3.825

2.  GAVA: spectral simulation for in vivo MRS applications.

Authors:  Brian J Soher; Karl Young; Aaron Bernstein; Zakaria Aygula; Andrew A Maudsley
Journal:  J Magn Reson       Date:  2007-01-12       Impact factor: 2.229

3.  Simultaneous detection of resolved glutamate, glutamine, and gamma-aminobutyric acid at 4 T.

Authors:  Jiani Hu; Shaolin Yang; Yang Xuan; Quan Jiang; Yihong Yang; E Mark Haacke
Journal:  J Magn Reson       Date:  2006-12-22       Impact factor: 2.229

4.  Improved localization, spectral quality, and repeatability with advanced MRS methodology in the clinical setting.

Authors:  Dinesh K Deelchand; Kejal Kantarci; Gülin Öz
Journal:  Magn Reson Med       Date:  2017-06-15       Impact factor: 4.668

5.  Comparison of spectral fitting methods for overlapping J-coupled metabolite resonances.

Authors:  A Gonenc; V Govind; S Sheriff; A A Maudsley
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

6.  Simultaneous editing of GABA and glutathione at 7T using semi-LASER localization.

Authors:  Muhammad G Saleh; Mark Mikkelsen; Georg Oeltzschner; Kimberly L Chan; Adam Berrington; Peter B Barker; Richard A E Edden
Journal:  Magn Reson Med       Date:  2017-12-28       Impact factor: 4.668

7.  Transverse relaxation time constants of the five major metabolites in human brain measured in vivo using LASER and PRESS at 3 T.

Authors:  Dinesh K Deelchand; Edward J Auerbach; Naoharu Kobayashi; Małgorzata Marjańska
Journal:  Magn Reson Med       Date:  2017-07-10       Impact factor: 4.668

8.  MR proton spectroscopy for myocardial lipid deposition quantification: a quantitative comparison between 1.5T and 3T.

Authors:  Bharath Ambale Venkatesh; Joao A C Lima; David A Bluemke; Shenghan Lai; Charles Steenbergen; Chia-Ying Liu
Journal:  J Magn Reson Imaging       Date:  2012-07-23       Impact factor: 4.813

9.  Numerical simulations of localized high field 1H MR spectroscopy.

Authors:  Lana G Kaiser; Karl Young; Gerald B Matson
Journal:  J Magn Reson       Date:  2008-08-28       Impact factor: 2.229

10.  RF pulses for in vivo spectroscopy at high field designed under conditions of limited power using optimal control.

Authors:  Gerald B Matson; Karl Young; Lana G Kaiser
Journal:  J Magn Reson       Date:  2009-03-31       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.