Literature DB >> 28691380

Transverse relaxation time constants of the five major metabolites in human brain measured in vivo using LASER and PRESS at 3 T.

Dinesh K Deelchand1, Edward J Auerbach1, Naoharu Kobayashi1, Małgorzata Marjańska1.   

Abstract

PURPOSE: The goal of this study was to measure and compare the apparent transverse relaxation time constants (T2 ) of five intracellular metabolites using localization by adiabatic selective refocusing (LASER) and point-resolved spectroscopy (PRESS) sequences in the human brain at 3 T.
METHODS: Five healthy subjects were studied at 3 T. 1 H spectra from the prefrontal cortex were acquired at six different echo times using LASER and PRESS sequences. Postprocessed data were analyzed with LCModel, and the resulting amplitudes were fitted using a mono-exponential decay function to determine the T2 of metabolites.
RESULTS: Twenty-one percent higher apparent T2 values for the singlet resonances of N-acetyl aspartate, total creatine, and total choline were measured with LASER as compared with PRESS, whereas comparable apparent T2 values were measured for strongly coupled metabolites, glutamate, and myo-inositol, with both sequences.
CONCLUSIONS: Reliable T2 measurements were obtained with both sequences for the five major intracellular metabolites. The LASER sequence appears to be more efficient in suppressing the diffusion component for singlets (having nonexchangeable protons) compared to J-coupled metabolites. Magn Reson Med 79:1260-1265, 2018.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  3 T; LASER; PRESS; T2 relaxation time constants; brain

Mesh:

Year:  2017        PMID: 28691380      PMCID: PMC5762441          DOI: 10.1002/mrm.26826

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  24 in total

1.  Proton T2 relaxation study of water, N-acetylaspartate, and creatine in human brain using Hahn and Carr-Purcell spin echoes at 4T and 7T.

Authors:  Shalom Michaeli; Michael Garwood; Xiao-Hong Zhu; Lance DelaBarre; Peter Andersen; Gregor Adriany; Hellmut Merkle; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

2.  In vivo 1H2O T2+ measurement in the human occipital lobe at 4T and 7T by Carr-Purcell MRI: detection of microscopic susceptibility contrast.

Authors:  Robert Bartha; Shalom Michaeli; Hellmut Merkle; Gregor Adriany; Peter Andersen; Wei Chen; Kamil Ugurbil; Michael Garwood
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

Review 3.  Adiabatic pulses.

Authors:  A Tannús; M Garwood
Journal:  NMR Biomed       Date:  1997-12       Impact factor: 4.044

4.  Observation of coupled 1H metabolite resonances at long TE.

Authors:  Brian J Soher; Pradip M Pattany; Gerald B Matson; Andrew A Maudsley
Journal:  Magn Reson Med       Date:  2005-06       Impact factor: 4.668

5.  Localized 1H NMR spectroscopy in different regions of human brain in vivo at 7 T: T2 relaxation times and concentrations of cerebral metabolites.

Authors:  Małgorzata Marjańska; Edward J Auerbach; Romain Valabrègue; Pierre-François Van de Moortele; Gregor Adriany; Michael Garwood
Journal:  NMR Biomed       Date:  2011-07-27       Impact factor: 4.044

6.  T2 measurement of J-coupled metabolites in the human brain at 3T.

Authors:  Sandeep K Ganji; Abhishek Banerjee; Aditya M Patel; Yan D Zhao; Ivan E Dimitrov; Jeffrey D Browning; E Sherwood Brown; Elizabeth A Maher; Changho Choi
Journal:  NMR Biomed       Date:  2011-08-15       Impact factor: 4.044

7.  Effect of Carr-Purcell refocusing pulse trains on transverse relaxation times of metabolites in rat brain at 9.4 Tesla.

Authors:  Dinesh Kumar Deelchand; Pierre-Gilles Henry; Małgorzata Marjańska
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

8.  Anomalous transverse relaxation in 1H spectroscopy in human brain at 4 Tesla.

Authors:  S Posse; C A Cuenod; R Risinger; D Le Bihan; R S Balaban
Journal:  Magn Reson Med       Date:  1995-02       Impact factor: 4.668

9.  Numerical simulations of localized high field 1H MR spectroscopy.

Authors:  Lana G Kaiser; Karl Young; Gerald B Matson
Journal:  J Magn Reson       Date:  2008-08-28       Impact factor: 2.229

10.  Faster metabolite (1)H transverse relaxation in the elder human brain.

Authors:  Małgorzata Marjańska; Uzay E Emir; Dinesh K Deelchand; Melissa Terpstra
Journal:  PLoS One       Date:  2013-10-02       Impact factor: 3.240

View more
  5 in total

1.  Changes in the intracellular microenvironment in the aging human brain.

Authors:  Dinesh K Deelchand; J Riley McCarten; Laura S Hemmy; Edward J Auerbach; Lynn E Eberly; Małgorzata Marjańska
Journal:  Neurobiol Aging       Date:  2020-07-25       Impact factor: 4.673

2.  The influence of cystathionine on neurochemical quantification in brain tumor in vivo MR spectroscopy.

Authors:  Francesca Branzoli; Dinesh K Deelchand; Roberto Liserre; Pietro Luigi Poliani; Lucia Nichelli; Marc Sanson; Stéphane Lehéricy; Małgorzata Marjańska
Journal:  Magn Reson Med       Date:  2022-04-05       Impact factor: 3.737

3.  Across-vendor standardization of semi-LASER for single-voxel MRS at 3T.

Authors:  Dinesh K Deelchand; Adam Berrington; Ralph Noeske; James M Joers; Arvin Arani; Joseph Gillen; Michael Schär; Jon-Fredrik Nielsen; Scott Peltier; Navid Seraji-Bozorgzad; Karl Landheer; Christoph Juchem; Brian J Soher; Douglas C Noll; Kejal Kantarci; Eva M Ratai; Thomas H Mareci; Peter B Barker; Gülin Öz
Journal:  NMR Biomed       Date:  2019-12-18       Impact factor: 4.044

4.  Quantification of in vivo transverse relaxation of glutamate in the frontal cortex of human brain by radio frequency pulse-driven longitudinal steady state.

Authors:  Ningzhi Li; Linqing Li; Yan Zhang; Maria Ferraris Araneta; Christopher Johnson; Jun Shen
Journal:  PLoS One       Date:  2019-04-17       Impact factor: 3.240

5.  In vivo 1 H MR spectroscopy with J-refocusing.

Authors:  Dinesh K Deelchand; Jamie D Walls; Małgorzata Marjańska
Journal:  Magn Reson Med       Date:  2021-07-26       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.