Literature DB >> 15686240

The standard Gamma nail or the Medoff sliding plate for unstable trochanteric and subtrochanteric fractures. A randomised, controlled trial.

R Miedel1, S Ponzer, H Törnkvist, A Söderqvist, J Tidermark.   

Abstract

We studied 217 patients with an unstable trochanteric or subtrochanteric fracture who had been randomly allocated to treatment by either internal fixation with a standard Gamma nail (SGN) or a Medoff sliding plate (MSP, biaxial dynamisation mode). Their mean age was 84 years (65 to 99) and they were reviewed at four and 12 months after surgery. Assessments of outcome included general complications, technical failures, revision surgery, activities of daily living (ADL), hip function (Charnley score) and the health-related quality of life (HRQOL, EQ-5D). The rate of technical failure in patients with unstable trochanteric fractures was 6.5% (6/93) (including intra-operative femoral fractures) in the SGN group and 5.2% (5/96) in the MSP group. In patients with subtrochanteric fractures, there were no failures in the SGN group (n = 16) and two in the MSP group (n = 12). In the SGN group, there were intra-operative femoral fractures in 2.8% (3/109) and no post-operative fractures. There was a reduced need for revision surgery in the SGN group compared with the MSP group (8.3%; 9/108; p = 0.072). The SGN group also showed a lower incidence of severe general complications (p < 0.05) and a trend towards a lower incidence of wound infections (p = 0.05). There were no differences between the groups regarding the outcome of ADL, hip function or the HRQOL. The reduction in the HRQOL (EQ-5D(index) score) was significant in both groups compared with that before the fracture (p < 0.005). Our findings indicate that the SGN showed good results in both trochanteric and subtrochanteric fractures. The limited number of intra-operative femoral fractures did not influence the outcome or the need for revision surgery. Moreover, the SGN group had a reduced number of serious general complications and wound infections compared with the MSP group. The MSP in the biaxial dynamisation mode had a low rate of failure in trochanteric fractures but an unacceptably high rate when used in the biaxial dynamisation mode in subtrochanteric fractures. The negative influence of an unstable trochanteric or subtrochanteric fracture on the quality of life was significant regardless of the surgical method.

Entities:  

Mesh:

Year:  2005        PMID: 15686240

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  40 in total

1.  Fixation of basicervical and related fractures.

Authors:  Elsayed Ibraheem Elsayed Massoud
Journal:  Int Orthop       Date:  2009-05-28       Impact factor: 3.075

Review 2.  [Pertrochanteric femoral fractures in the elderly].

Authors:  G H Sandmann; P Biberthaler
Journal:  Unfallchirurg       Date:  2015-05       Impact factor: 1.000

3.  Intramedullary versus extramedullary fixation in the treatment of subtrochanteric femur fractures: A comprehensive systematic review and meta-analysis.

Authors:  Jie Wang; Haomin Li; Haobo Jia; Xinlong Ma
Journal:  Acta Orthop Traumatol Turc       Date:  2020-11       Impact factor: 1.511

4.  3066 consecutive Gamma Nails. 12 years experience at a single centre.

Authors:  Alicja J Bojan; Claudia Beimel; Andreas Speitling; Gilbert Taglang; Carl Ekholm; Anders Jönsson
Journal:  BMC Musculoskelet Disord       Date:  2010-06-26       Impact factor: 2.362

5.  [Stabilization of inter- and subtrochanteric femoral fractures with the PFNΑ®].

Authors:  O Büttner; S Styger; P Regazzoni; N Suhm
Journal:  Oper Orthop Traumatol       Date:  2011-12       Impact factor: 1.154

6.  [Complications after pertrochanteric fractures].

Authors:  B Füchtmeier; F Gebhard; A Lenich
Journal:  Unfallchirurg       Date:  2011-06       Impact factor: 1.000

Review 7.  [Trochanteric femoral fractures: anatomy, biomechanics and choice of implants].

Authors:  F Bonnaire; T Lein; P Bula
Journal:  Unfallchirurg       Date:  2011-06       Impact factor: 1.000

8.  CORR Insights™: Intramedullary nails result in more reoperations than sliding hip screws in two-part intertrochanteric fractures.

Authors:  Paul J Dougherty
Journal:  Clin Orthop Relat Res       Date:  2013-04       Impact factor: 4.176

9.  Fixation of subtrochanteric fractures : Does a technical optimization of the dynamic hip screw application improve the results?

Authors:  Elsayed Ibraheem Elsayed Massoud
Journal:  Strategies Trauma Limb Reconstr       Date:  2009-06-06

10.  Role of gamma nail in management of pertrochanteric fractures of femur.

Authors:  Vipin Sharma; Sushrut Babhulkar; Sudhir Babhulkar
Journal:  Indian J Orthop       Date:  2008-04       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.