BACKGROUND: Physical performance measures play an important role in the measurement of outcome in patients undergoing hip and knee arthroplasty. However, many of the commonly used measures lack information on their psychometric properties in this population. The purposes of this study were to examine the reliability and sensitivity to change of the six minute walk test (6MWT), timed up and go test (TUG), stair measure (ST), and a fast self-paced walk test (SPWT) in patients with hip or knee osteoarthritis (OA) who subsequently underwent total joint arthroplasty.Entities:
Mesh:
Year: 2005 PMID: 15679884 PMCID: PMC549207 DOI: 10.1186/1471-2474-6-3
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Sample Characteristics
| n = 150 | Mean, SD | Quartiles |
| Age (yr) | 63.7, 10.7 | 57, 64, 72 |
| Height (m) | 1.69, 0.09 | 1.62, 1.68, 1.76 |
| Weight (kg) | 85.5, 15.4 | 74.3, 83.3, 94.2 |
| Body mass index (kg/m2) | 30.0, 4.9 | 26.3, 28.9, 33.4 |
n, Number of subjects
Yr, year
M, meter
Kg, kilogram
SD, standard deviation
Figure 1Study Design
Figure 2Distribution of Times to Complete the Fast Self-Paced Walk Test
Figure 3Distribution of Preoperative Stair Test Times
Figure 4Distribution of Preoperative Timed Up and Go Test Times
Figure 5Distribution of Preoperative 6 Minute Walk Test Distances
Reliability Coefficients and Minimal Level of Detectable Change
| Measure | R (95% CI) | SEM (95% CI) | Confidence in Score (90% CI) | MDC90 |
| Fast Self-paced Walk Time (completed over 40 meters) | 0.91 (0.81, 0.97) | 1.73 (1.39, 2.29) | ± 2.86 s | 4.04 s |
| Stair Time | 0.90 (0.79, 0.96) | 2.35 (1.89, 3.10) | ± 3.88 s | 5.49 s |
| Timed Up and Go Time | 0.75 (0.51, 0.89) | 1.07 (0.86, 1.41) | ± 1.76s | 2.49 s |
| Six Minute Walk Test Distance | 0.94 (0.88, 0.98) | 26.29 (21.14, 34.77) | ± 43.37 m | 61.34 m |
R, Reliability Coefficient
SEM, Standard Error of Measurement
MDC90, Minimal detectable change at the 90% confidence Level
s, seconds
m, meters
Mean and Quartile Scores of the Performance Measures across Time
| Measure | Preop | Postop 1 | Postop 2 |
| Self-paced Walk Time (seconds) | 31.7, 9.2 | 85.7, 62.7, 115 | 33.7, 10.9, 92 |
| Stair Time (seconds) | 17.1, 8.2 | 40, 12, 87 | 20.0, 9.7, 91 |
| Timed Up and Go Time (seconds) | 9.8, 3.2 | 24.7, 14.2, 116 | 10.3, 4.2, 91 |
| Six minute Walk Test Distance (meters) | 412, 123 | 193, 87, 82 | 408, 116, 91 |
SD, Standard Deviation
n, Number of subjects
Change Scores and Standardized Response Means
| Measure | Preop to First Postop Interval Mean Change*, SD, n SRM* (95% CI) | First to Second Postop Interval Mean Change*, SD, n SRM* (95% CI) |
| Self-paced Walk Time (seconds) | -54.8, 61.6, 115 | 47.7, 60.7, 89 |
| Stair Time (seconds) | -23.8, 13.8, 87 | 20.59, 10.40, 73 |
| Timed Up and Go Time (seconds) | -14.9, 13.8, 116 | 13.57, 13.04, 89 |
| Six minute Walk Test Distance (meters) | -232, 133, 82 | 207, 109, 61 |
* Negative sign indicates a worsening in the measured value; positive sign indicates an improvement in the measured value
SD, Standard Deviation
SRM, Standardized Response Mean
n, Number of subjects
CI, Confidence Intervals
Missing Values Details
| Measure | Time 2 | Time 3 |
| Self-paced Walk | ||
| Completed Test | 115 | 92 |
| Unable to Complete Test | 4 | 0 |
| Missing | 0 | 1 |
| Stair Test | ||
| Completed Test | 87 | 91 |
| Unable to Complete Test | 29 | 1 |
| Missing | 3 | 1 |
| Timed Up and Go Test | ||
| Completed Test | 116 | 91 |
| Unable to Complete Test | 3 | 0 |
| Missing | 0 | 2 |
| Six minute Walk Test | ||
| Completed Test | 82 | 87 |
| Unable to Complete Test | 33 | 1 |
| Missing | 4 | 5 |