PURPOSE: The 6-min walk test is a simple clinical outcome measure, which has been used frequently to assess functional performance in many different patient groups, including patients with total knee arthroplasty (TKA). The 6-min walk test measures the maximal distance a subject is able to walk in 6 min. The reliability is unknown in patients with TKA. Therefore, the purpose of the study was to assess the reliability of the 6-min walk test in patients with recent TKA. METHODS: Thirty-four patients with TKA performed 2 test trials the same day, separated by a 1-h seated rest. To assess reliability, intra-class correlation coefficient (ICC2,1), standard error of measurement (SEM), and smallest real difference (SRD) were calculated. RESULTS: The patients walked on average 14.1 m longer at the second (397.2 m) compared to the first (383.1 m) test trial. The ICC2,1, SEM, and SRD were 0.97, 13.0, and 36.1 m, respectively. CONCLUSIONS: The intra-tester reliability of the 6-min walk test was high in patients with TKA. The thresholds of the 6-min walk test to detect a real change are acceptable in research (SEM) and clinical settings (SRD). We recommend that the longest distance walked in 2 supervised test trials should be used.
PURPOSE: The 6-min walk test is a simple clinical outcome measure, which has been used frequently to assess functional performance in many different patient groups, including patients with total knee arthroplasty (TKA). The 6-min walk test measures the maximal distance a subject is able to walk in 6 min. The reliability is unknown in patients with TKA. Therefore, the purpose of the study was to assess the reliability of the 6-min walk test in patients with recent TKA. METHODS: Thirty-four patients with TKA performed 2 test trials the same day, separated by a 1-h seated rest. To assess reliability, intra-class correlation coefficient (ICC2,1), standard error of measurement (SEM), and smallest real difference (SRD) were calculated. RESULTS: The patients walked on average 14.1 m longer at the second (397.2 m) compared to the first (383.1 m) test trial. The ICC2,1, SEM, and SRD were 0.97, 13.0, and 36.1 m, respectively. CONCLUSIONS: The intra-tester reliability of the 6-min walk test was high in patients with TKA. The thresholds of the 6-min walk test to detect a real change are acceptable in research (SEM) and clinical settings (SRD). We recommend that the longest distance walked in 2 supervised test trials should be used.
Authors: Deborah M Kennedy; Paul W Stratford; Jean Wessel; Jeffrey D Gollish; Dianne Penney Journal: BMC Musculoskelet Disord Date: 2005-01-28 Impact factor: 2.362
Authors: Jesse C Christensen; Jacob J Capin; Lauren A Hinrichs; Moiyad Aljehani; Jennifer E Stevens-Lapsley; Joseph A Zeni Journal: J Orthop Res Date: 2020-11-02 Impact factor: 3.102
Authors: Rasmus Skov Husted; Anders Troelsen; Kristian Thorborg; Michael Skovdal Rathleff; Henrik Husted; Thomas Bandholm Journal: Trials Date: 2018-01-18 Impact factor: 2.279
Authors: Munayati Munajat; Nor Azlin Mohd Nordin; Nor Hamdan Mohamad Yahya; Ahmad Hafiz Zulkifly Journal: Medicine (Baltimore) Date: 2019-09 Impact factor: 1.889