Literature DB >> 15676014

Persistent Legionella pneumophila colonization of a hospital water supply: efficacy of control methods and a molecular epidemiological analysis.

Outi Perola1, Juha Kauppinen, Jaana Kusnetsov, Ulla-Maija Kärkkäinen, P Christian Lück, Marja-Leena Katila.   

Abstract

After a nosocomial outbreak caused by Legionella pneumophila serogroup 5, the hospital water distribution system, which was found to be colonized by L. pneumophila serogroups 5 and 6, was decontaminated by the superheat and flush method and by installing an additional heat-shock unit in one of the hot water circuits. This unit exposed the recirculated water to a temperature of 80 degrees C. The efficacy of the decontamination measures was evaluated by monitoring the temperatures and legionella concentrations at different parts of the hot water distribution system. The genetic diversity of the colonizing legionella flora was examined using two genotyping methods: amplified fragment length polymorphism analysis (AFLP) and random amplified polymorphic DNA (RAPD) analysis. Selected serogroup 6 strains were also analyzed by sequence-based typing (SBT). The results indicated that long-term eradication of serogroup 5 strains was never achieved. Only one serogroup 6 strain was never isolated after the superheat and flush. In all, according to genetic fingerprints, the diversity of Legionella strains in a hospital water system remains stable over the years regardless of the use of recommended disinfection procedures.

Entities:  

Mesh:

Year:  2005        PMID: 15676014     DOI: 10.1111/j.1600-0463.2005.apm1130107.x

Source DB:  PubMed          Journal:  APMIS        ISSN: 0903-4641            Impact factor:   3.205


  12 in total

1.  Two Legionnaires' disease cases associated with industrial waste water treatment plants: a case report.

Authors:  Jaana Kusnetsov; Liisa-Kaarina Neuvonen; Timo Korpio; Søren A Uldum; Silja Mentula; Tuula Putus; Nhu Nguyen Tran Minh; Kari-Pekka Martimo
Journal:  BMC Infect Dis       Date:  2010-12-02       Impact factor: 3.090

2.  Distribution of Legionella pneumophila serogroups, monoclonal antibody subgroups and DNA sequence types in recent clinical and environmental isolates from England and Wales (2000-2008).

Authors:  T G Harrison; B Afshar; N Doshi; N K Fry; J V Lee
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2009-01-21       Impact factor: 3.267

3.  Genomic Analysis Reveals Novel Diversity among the 1976 Philadelphia Legionnaires' Disease Outbreak Isolates and Additional ST36 Strains.

Authors:  Jeffrey W Mercante; Shatavia S Morrison; Heta P Desai; Brian H Raphael; Jonas M Winchell
Journal:  PLoS One       Date:  2016-09-29       Impact factor: 3.240

4.  Energy Conservation and the Promotion of Legionella pneumophila Growth: The Probable Role of Heat Exchangers in a Nosocomial Outbreak.

Authors:  Emilie Bédard; Simon Lévesque; Philippe Martin; Linda Pinsonneault; Kiran Paranjape; Cindy Lalancette; Charles-Éric Dolcé; Manuela Villion; Louis Valiquette; Sébastien P Faucher; Michèle Prévost
Journal:  Infect Control Hosp Epidemiol       Date:  2016-09-19       Impact factor: 3.254

5.  Prevalence of Infection-Competent Serogroup 6 Legionella pneumophila within Premise Plumbing in Southeast Michigan.

Authors:  Brenda G Byrne; Sarah McColm; Shawn P McElmurry; Paul E Kilgore; Joanne Sobeck; Rick Sadler; Nancy G Love; Michele S Swanson
Journal:  MBio       Date:  2018-02-06       Impact factor: 7.867

6.  Preventing Healthcare-Associated Legionellosis: Results after 3 Years of Continuous Disinfection of Hot Water with Monochloramine and an Effective Water Safety Plan.

Authors:  Maria Anna Coniglio; Margherita Ferrante; Mohamed H Yassin
Journal:  Int J Environ Res Public Health       Date:  2018-07-27       Impact factor: 3.390

7.  Spatial structuring of a Legionella pneumophila population within the water system of a large occupational building.

Authors:  Sophia David; Massimo Mentasti; Sandra Lai; Lalita Vaghji; Derren Ready; Victoria J Chalker; Julian Parkhill
Journal:  Microb Genom       Date:  2018-10-12

8.  Environmental Surveillance of Legionellosis within an Italian University Hospital-Results of 15 Years of Analysis.

Authors:  Pasqualina Laganà; Alessio Facciolà; Roberta Palermo; Santi Delia
Journal:  Int J Environ Res Public Health       Date:  2019-03-28       Impact factor: 3.390

Review 9.  Legionella Persistence in Manufactured Water Systems: Pasteurization Potentially Selecting for Thermal Tolerance.

Authors:  Harriet Whiley; Richard Bentham; Melissa H Brown
Journal:  Front Microbiol       Date:  2017-07-19       Impact factor: 5.640

10.  Seeding and Establishment of Legionella pneumophila in Hospitals: Implications for Genomic Investigations of Nosocomial Legionnaires' Disease.

Authors:  Sophia David; Baharak Afshar; Massimo Mentasti; Christophe Ginevra; Isabelle Podglajen; Simon R Harris; Victoria J Chalker; Sophie Jarraud; Timothy G Harrison; Julian Parkhill
Journal:  Clin Infect Dis       Date:  2017-05-01       Impact factor: 20.999

View more