Literature DB >> 21126333

Two Legionnaires' disease cases associated with industrial waste water treatment plants: a case report.

Jaana Kusnetsov1, Liisa-Kaarina Neuvonen, Timo Korpio, Søren A Uldum, Silja Mentula, Tuula Putus, Nhu Nguyen Tran Minh, Kari-Pekka Martimo.   

Abstract

BACKGROUND: Finnish and Swedish waste water systems used by the forest industry were found to be exceptionally heavily contaminated with legionellae in 2005. CASE
PRESENTATION: We report two cases of severe pneumonia in employees working at two separate mills in Finland in 2006. Legionella serological and urinary antigen tests were used to diagnose Legionnaires' disease in the symptomatic employees, who had worked at, or close to, waste water treatment plants. Since the findings indicated a Legionella infection, the waste water and home water systems were studied in more detail. The antibody response and Legionella urinary antigen finding of Case A indicated that the infection had been caused by Legionella pneumophila serogroup 1. Case A had been exposed to legionellae while installing a pump into a post-clarification basin at the waste water treatment plant of mill A. Both the water and sludge in the basin contained high concentrations of Legionella pneumophila serogroup 1, in addition to serogroups 3 and 13. Case B was working 200 meters downwind from a waste water treatment plant, which had an active sludge basin and cooling towers. The antibody response indicated that his disease was due to Legionella pneumophila serogroup 2. The cooling tower was the only site at the waste water treatment plant yielding that serogroup, though water in the active sludge basin yielded abundant growth of Legionella pneumophila serogroup 5 and Legionella rubrilucens. Both workers recovered from the disease.
CONCLUSION: These are the first reported cases of Legionnaires' disease in Finland associated with industrial waste water systems.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21126333      PMCID: PMC3014939          DOI: 10.1186/1471-2334-10-343

Source DB:  PubMed          Journal:  BMC Infect Dis        ISSN: 1471-2334            Impact factor:   3.090


  17 in total

1.  Pan-European study on culture-proven Legionnaires' disease: distribution of Legionella pneumophila serogroups and monoclonal subgroups.

Authors:  J H Helbig; S Bernander; M Castellani Pastoris; J Etienne; V Gaia; S Lauwers; D Lindsay; P C Lück; T Marques; S Mentula; M F Peeters; C Pelaz; M Struelens; S A Uldum; G Wewalka; T G Harrison
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2002-10-18       Impact factor: 3.267

2.  A newborn with domestically acquired legionnaires disease confirmed by molecular typing.

Authors:  Kirsi Skogberg; J Pekka Nuorti; Harri Saxen; Jaana Kusnetsov; Silja Mentula; Vineta Fellman; Nina Mäki-Petäys; Hannele Jousimies-Somer
Journal:  Clin Infect Dis       Date:  2002-09-19       Impact factor: 9.079

3.  Legionella bacteria in aerosols: sampling and analytical approaches used during the legionnaires disease outbreak in Pas-de-Calais.

Authors:  Laurence Mathieu; Enric Robine; Magali Deloge-Abarkan; Sebastien Ritoux; Daniele Pauly; Philippe Hartemann; Denis Zmirou-Navier
Journal:  J Infect Dis       Date:  2006-05-01       Impact factor: 5.226

4.  Seroepidemiological study after a long-distance industrial outbreak of legionnaires' disease.

Authors:  E Wedege; T Bergdal; K Bolstad; D A Caugant; J Efskind; H E Heier; A Kanestrøm; B H Strand; I S Aaberge
Journal:  Clin Vaccine Immunol       Date:  2009-02-18

5.  Rapid determination of 16S ribosomal RNA sequences for phylogenetic analyses.

Authors:  D J Lane; B Pace; G J Olsen; D A Stahl; M L Sogin; N R Pace
Journal:  Proc Natl Acad Sci U S A       Date:  1985-10       Impact factor: 11.205

6.  Occurrence of legionellae in hot water distribution systems of Finnish apartment buildings.

Authors:  O M Zacheus; P J Martikainen
Journal:  Can J Microbiol       Date:  1994-12       Impact factor: 2.419

7.  Antigenic lipopolysaccharide components of Legionella pneumophila recognized by monoclonal antibodies: possibilities and limitations for division of the species into serogroups.

Authors:  J H Helbig; J B Kurtz; M C Pastoris; C Pelaz; P C Lück
Journal:  J Clin Microbiol       Date:  1997-11       Impact factor: 5.948

8.  Legionnaires' disease: description of an epidemic of pneumonia.

Authors:  D W Fraser; T R Tsai; W Orenstein; W E Parkin; H J Beecham; R G Sharrar; J Harris; G F Mallison; S M Martin; J E McDade; C C Shepard; P S Brachman
Journal:  N Engl J Med       Date:  1977-12-01       Impact factor: 91.245

9.  Tracking airborne Legionella and Legionella pneumophila at a biological treatment plant.

Authors:  Janet Martha Blatny; Bjørn Anders P Reif; Gunnar Skogan; Oyvind Andreassen; E Arne Høiby; Eirik Ask; Viggo Waagen; Dag Aanonsen; Ingeborg S Aaberge; Dominique A Caugant
Journal:  Environ Sci Technol       Date:  2008-10-01       Impact factor: 9.028

10.  Ameba-associated microorganisms and diagnosis of nosocomial pneumonia.

Authors:  Pierre Berger; Laurent Papazian; Michel Drancourt; Bernard La Scola; Jean-Pierre Auffray; Didier Raoult
Journal:  Emerg Infect Dis       Date:  2006-02       Impact factor: 6.883

View more
  11 in total

1.  Isolation of Legionella pneumophila from pluvial floods by amoebal coculture.

Authors:  J A C Schalk; A E Docters van Leeuwen; W J Lodder; H de Man; S Euser; J W den Boer; A M de Roda Husman
Journal:  Appl Environ Microbiol       Date:  2012-03-30       Impact factor: 4.792

Review 2.  Current and emerging Legionella diagnostics for laboratory and outbreak investigations.

Authors:  Jeffrey W Mercante; Jonas M Winchell
Journal:  Clin Microbiol Rev       Date:  2015-01       Impact factor: 26.132

3.  Occurrence of Legionella in wastewater treatment plants linked to wastewater characteristics.

Authors:  C Caicedo; S Beutel; T Scheper; K H Rosenwinkel; R Nogueira
Journal:  Environ Sci Pollut Res Int       Date:  2016-07-04       Impact factor: 4.223

4.  Ten Questions Concerning the Aerosolization and Transmission of Legionella in the Built Environment.

Authors:  Aaron J Prussin; David Otto Schwake; Linsey C Marr
Journal:  Build Environ       Date:  2017-06-13       Impact factor: 6.456

5.  Detection of Legionella spp. by a nested-PCR assay in air samples of a wastewater treatment plant and downwind distances in Isfahan.

Authors:  Seyyed Abbas Mirzaee; Mahnaz Nikaeen; Yaghob Hajizadeh; BiBi Fatemeh Nabavi; Akbar Hassanzadeh
Journal:  Adv Biomed Res       Date:  2015-02-17

Review 6.  Biologically hazardous agents at work and efforts to protect workers' health: a review of recent reports.

Authors:  Kyung-Taek Rim; Cheol-Hong Lim
Journal:  Saf Health Work       Date:  2014-04-05

7.  Industrial Cooling Tower Disinfection Treatment to Prevent Legionella spp.

Authors:  Matteo Iervolino; Benedetta Mancini; Sandra Cristino
Journal:  Int J Environ Res Public Health       Date:  2017-09-26       Impact factor: 3.390

8.  Probabilistic Analysis of a French Legionellosis Outbreak Shows Potential Role of Wastewater Basin.

Authors:  France Wallet; Leila Fontenay; Pierre-André Cabanes
Journal:  Microorganisms       Date:  2022-02-11

9.  Cross-reactions in IgM ELISA tests to Legionella pneumophila sg1 and Bordetella pertussis among children suspected of legionellosis; potential impact of vaccination against pertussis?

Authors:  Katarzyna Wanda Pancer
Journal:  Cent Eur J Immunol       Date:  2015-08-03       Impact factor: 2.085

10.  Two Community Clusters of Legionnaires' Disease Directly Linked to a Biologic Wastewater Treatment Plant, the Netherlands.

Authors:  Anna D Loenenbach; Christian Beulens; Sjoerd M Euser; Jeroen P G van Leuken; Ben Bom; Wim van der Hoek; Ana Maria de Roda Husman; Wilhelmina L M Ruijs; Alvin A Bartels; Ariene Rietveld; Jeroen W den Boer; Petra S Brandsema
Journal:  Emerg Infect Dis       Date:  2018-10       Impact factor: 6.883

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.