Literature DB >> 15668582

Treatment of osteopenic humeral shaft nonunion with compression plating, humeral cortical allograft struts, and bone grafting.

Andrew P Van Houwelingen1, Michael D McKee.   

Abstract

Surgical stabilization of humeral shaft nonunions can be difficult to achieve if severe osteopenia or loss of bone stock is present. We present a technique whereby a 4.5-mm standard dynamic compression plate is used in conjunction with a humeral cortical allograft strut and bone grafting to stabilize humeral shaft nonunions complicated by severe bone loss. Six patients with established nonunion of the humeral shaft underwent this technique. Union was achieved at an average of 3.4 months (range 2-6 months). Our method using onlay allograft struts can provide an effective alternative in the management of humeral shaft nonunion complicated by severe osteopenia of various etiologies.

Entities:  

Mesh:

Year:  2005        PMID: 15668582     DOI: 10.1097/00005131-200501000-00007

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  18 in total

1.  Shape memory Ni-Ti alloy swan-like bone connector for treatment of humeral shaft nonunion.

Authors:  Jia-Can Su; Xin-Wei Liu; Bao-Qing Yu; Zhuo-Dong Li; Ming Li; Chun-Cai Zhang
Journal:  Int Orthop       Date:  2009-02-07       Impact factor: 3.075

2.  Humeral shaft aseptic nonunion: treatment with opposite cortical allograft struts.

Authors:  Alessandro Marinelli; Diego Antonioli; Enrico Guerra; Graziano Bettelli; Lorenzo Zaccarelli; Roberto Rotini
Journal:  Chir Organi Mov       Date:  2009-04

3.  "Sandwich technique" in the surgical treatment of primary complex fractures of the femur and humerus.

Authors:  A Gogus; C Ozturk; M Tezer; K Camurdan; A Hamzaoglu
Journal:  Int Orthop       Date:  2006-05-12       Impact factor: 3.075

4.  Cortical onlay strut allograft with cerclage wiring of periprosthetic fractures of the humerus without stem loosening: technique and preliminary results.

Authors:  André Thés; Shahnaz Klouche; Marine de Tienda; Thomas Bauer; Philippe Hardy
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-04-08

5.  Management of humeral nonunions following failed surgical fixation.

Authors:  Andrew Lee; Trevor Wait; Kush Shah; Uchechukwuka Osadebe; Matthew Kergosien; Anil Dutta
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-29       Impact factor: 3.067

6.  Implementation of locking compression plate together with intramedullary fibular graft in atrophic type humeral nonunions.

Authors:  Erturer Ramazan Erden; Cınar Arda; Sonmez Mehmet Mesut; Kara Adnan; Ozcelik Ismail Bulent; Ozturk Irfan
Journal:  Eur J Orthop Surg Traumatol       Date:  2011-11-01

7.  Allografting in locked nailing and interfragmentary wiring for humeral nonunions.

Authors:  Wei-Peng Lin; Jinn Lin
Journal:  Clin Orthop Relat Res       Date:  2009-08-22       Impact factor: 4.176

Review 8.  Clinical applications of BMP-7/OP-1 in fractures, nonunions and spinal fusion.

Authors:  Andrew P White; Alexander R Vaccaro; Jeremy A Hall; Peter G Whang; Brian C Friel; Michael D McKee
Journal:  Int Orthop       Date:  2007-07-25       Impact factor: 3.075

9.  Why a surgically treated humeral shaft fracture became a nonunion: review of 11 years in two trauma centers.

Authors:  A Maresca; P Sangiovanni; S Cerbasi; R Politano; R Fantasia; M Commessatti; R Pascarella
Journal:  Musculoskelet Surg       Date:  2017-10-19

Review 10.  The Clinical Application of Porous Tantalum and Its New Development for Bone Tissue Engineering.

Authors:  Gan Huang; Shu-Ting Pan; Jia-Xuan Qiu
Journal:  Materials (Basel)       Date:  2021-05-18       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.