Literature DB >> 27526067

Implementation of locking compression plate together with intramedullary fibular graft in atrophic type humeral nonunions.

Erturer Ramazan Erden1, Cınar Arda1, Sonmez Mehmet Mesut2, Kara Adnan1, Ozcelik Ismail Bulent3, Ozturk Irfan1.   

Abstract

OBJECTIVE: This study aims to report the results of locking compression plate along with intramedullary fibular graft that was implemented in patients with the diagnosis of nonunion of humerus diaphysis.
MATERIALS AND METHODS: Five patients, operated between 2000 and 2009 for atrophic type nonunion of humeral diaphysis, were included in this study. Two patients were women (40%) and three were men (60%). The mean age was 49.2 years. Nonunion was found to be on the right humerus of 3 patients and on the left side of 2 patients. Causes of fractures were traffic accident in 2 cases, simple fall in 2 cases, and fall from height in 1 case. Mean duration after the elementary fracture was 70 months. Nonunion was diagnosed at 1/3 proximal humeral diaphysis in 2 patients, 1/3 distal humeral diaphysis in 2 patients, and 1/3 middle humeral diaphysis in one patient. Initially, conservative treatment was chosen for 3 cases and plate-screw osteosynthesis for 2 cases.
RESULTS: Complete union was obtained in all cases radiologically. Mean union time was 20.1 weeks. With a mean of 1.78 cm, shortening was detected in comparative radiographies of both humeri. Mean range of motion at the elbow was 118° in flexion-extension arch of patients. The mean Constant-Murley score was 88 points. There was no complication regarding the operation and graft donor sites.
CONCLUSION: The management of atrophic type humeral nonunions is difficult. The method that we practice in such patients is a reliable treatment option with its stabile fixation and high union rates.

Entities:  

Keywords:  Fibular allograft; Humerus fracture; Nonunion; Plate osteosynthesis; Surgical treatment

Year:  2011        PMID: 27526067     DOI: 10.1007/s00590-011-0900-0

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  19 in total

1.  Open reduction and internal fixation of humeral nonunions : a biomechanical and clinical study.

Authors:  Iván F Rubel; Peter Kloen; Deirdre Campbell; Mark Schwartz; Alan Liew; Elizabeth Myers; David L Helfet
Journal:  J Bone Joint Surg Am       Date:  2002-08       Impact factor: 5.284

2.  [The effectiveness of functional bracing in the conservative treatment of humeral diaphyseal fractures].

Authors:  Irfan Oztürk; Erden Ertürer; Metin Uzun; Senol Akman; Faik Seçkin
Journal:  Acta Orthop Traumatol Turc       Date:  2006       Impact factor: 1.511

3.  A clinical method of functional assessment of the shoulder.

Authors:  C R Constant; A H Murley
Journal:  Clin Orthop Relat Res       Date:  1987-01       Impact factor: 4.176

4.  Reconstruction of the humerus with an intramedullary fibular graft. A clinical and biomechanical study.

Authors:  T W Wright; G J Miller; R A Vander Griend; D Wheeler; P C Dell
Journal:  J Bone Joint Surg Br       Date:  1993-09

5.  Treatment of nonunion of the humerus using the Ilizarov external fixator.

Authors:  J Lammens; G Bauduin; R Driesen; P Moens; J Stuyck; L De Smet; G Fabry
Journal:  Clin Orthop Relat Res       Date:  1998-08       Impact factor: 4.176

6.  Use of locking compression plates for long bone nonunions without removing existing intramedullary nail: review of literature and our experience.

Authors:  Biren Nadkarni; Shekhar Srivastav; Vivek Mittal; Shekhar Agarwal
Journal:  J Trauma       Date:  2008-08

7.  Treatment of the humeral shaft nonunion after surgical failure using the Selfdynamisable internal fixator.

Authors:  Ivan Micic; Milorad Mitkovic; Desimir Mladenovic; Milos Stanojlovic; In Ho Jeon
Journal:  Arch Orthop Trauma Surg       Date:  2007-04-25       Impact factor: 3.067

8.  Diaphyseal fractures of the humerus treated with a ready-made fracture brace.

Authors:  G W Balfour; V Mooney; M E Ashby
Journal:  J Bone Joint Surg Am       Date:  1982-01       Impact factor: 5.284

Review 9.  Advances in the management of humeral nonunion.

Authors:  David M W Pugh; Michael D McKee
Journal:  J Am Acad Orthop Surg       Date:  2003 Jan-Feb       Impact factor: 3.020

10.  Treatment for nonunion of the shaft of the humerus: comparison of plates and Seidel interlocking nails.

Authors:  C C Wu; C H Shih
Journal:  Can J Surg       Date:  1992-12       Impact factor: 2.089

View more
  1 in total

1.  Role of autologous non-vascularised intramedullary fibular strut graft in humeral shaft nonunions following failed plating.

Authors:  Sreekanth Kashayi-Chowdojirao; Aashish Vallurupalli; Vijay Krishna Chilakamarri; Chandrasekhar Patnala; Lalith Mohan Chodavarapu; Nageswara Rao Kancherla; Asif Hussain Khazi Syed
Journal:  J Clin Orthop Trauma       Date:  2016-12-22
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.