Literature DB >> 15662312

Implant survivorship and complication rates after total knee arthroplasty with a third-generation cemented system: 5 to 8 years followup.

Kevin J Bozic1, Jeremy Kinder, R Michael Meneghini, Michael Menegini, David Zurakowski, Aaron G Rosenberg, Jorge O Galante.   

Abstract

UNLABELLED: We evaluated implant survivorship, reoperation rates, and complication rates of a group of patients who had total knee arthroplasty with a third-generation cemented prosthetic device using cruciate-retaining and posterior-stabilized designs at 5 to 8 years followup. Three hundred thirty-four consecutive primary total knee arthroplasties (186 cruciate retaining and 148 posterior stabilized) were done in 287 patients at our institution during a 2-year period. Kaplan Meier survivorship using revision for any reason and revision for aseptic loosening as endpoints were 95.9% and 99.5% respectively at 8 years. Nine patients (four with cruciate-retaining total knee arthroplasties, five with posterior-stabilized total knee arthroplasties; 3.1%) had reoperations for any reason. No patients had reoperation for problems related to the patellofemoral joint. Thirty-two patients (11.1%) had intraoperative or postoperative complications. There were no differences in any of the outcomes analyzed between patients who had cruciate-retaining or posterior-stabilized total knee replacements. Our results show that with appropriate patient selection and meticulous attention to surgical technique, excellent clinical and radiographic results can be achieved with a third-generation total knee arthroplasty system at intermediate followup. LEVEL OF EVIDENCE: Therapeutic study, Level III-2 (retrospective cohort study).

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15662312     DOI: 10.1097/01.blo.0000146539.23869.14

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  19 in total

1.  Hybrid total knee arthroplasty: 13-year survivorship of AGC total knee systems with average 7 years followup.

Authors:  Philip M Faris; E Michael Keating; Alex Farris; John B Meding; Merrill A Ritter
Journal:  Clin Orthop Relat Res       Date:  2008-03-07       Impact factor: 4.176

2.  Successful LCL reconstruction and PCL repair for LCL tear and PCL avulsion following total knee arthroplasty.

Authors:  Michael A Flierl; Jonathan T Bravman; Donald G Eckhoff
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-06-12       Impact factor: 4.342

3.  A 5 to 8 year follow-up study of the Rotaglide mobile bearing total knee arthroplasty.

Authors:  Alastair Hudd; Kumar Kunasingam; David Ricketts; John Bush
Journal:  Int Orthop       Date:  2008-07-02       Impact factor: 3.075

4.  Do high flexion posterior stabilised total knee arthroplasty designs increase knee flexion? A meta analysis.

Authors:  Takanobu Sumino; Hemanth R Gadikota; Kartik M Varadarajan; Young-Min Kwon; Harry E Rubash; Guoan Li
Journal:  Int Orthop       Date:  2011-03-16       Impact factor: 3.075

5.  Cruciate-retaining TKA using a third-generation system with a four-pegged tibial component: a minimum 10-year followup note.

Authors:  Adam J Schwartz; Craig J Della Valle; Aaron G Rosenberg; Joshua J Jacobs; Richard A Berger; Jorge O Galante
Journal:  Clin Orthop Relat Res       Date:  2010-05-04       Impact factor: 4.176

6.  The Rotaglide mobile-bearing total knee arthroplasty: no difference between cemented and hybrid implantation.

Authors:  Michael Iosifidis; Efthymios Iliopoulos; Dimos Neofytou; Nikolaos Sakorafas; Dimitrios Andreou; Dimitrios Alvanos; Anastasios Kyriakidis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-12       Impact factor: 4.342

7.  Osteolysis in well-functioning fixed- and mobile-bearing TKAs in younger patients.

Authors:  Young-Hoo Kim; Yoowang Choi; Jun-Shik Kim
Journal:  Clin Orthop Relat Res       Date:  2010-04-01       Impact factor: 4.176

8.  Long-term follow-up of a non-randomised prospective cohort of one hundred and ninety two total knee arthroplasties using the NexGen implant.

Authors:  Alfredo Schiavone Panni; Franceso Falez; Rocco D'Apolito; Katia Corona; Carlo Perisano; Michele Vasso
Journal:  Int Orthop       Date:  2017-03-22       Impact factor: 3.075

9.  Total knee replacement: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2005-06-01

10.  [Total knee arthroplasty - GPs' views in Germany: a questionnaire-based study].

Authors:  C Rau; M Zimmermann-Stenzel; D Parsch
Journal:  Orthopade       Date:  2008-04       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.