Literature DB >> 1565698

Alternatives to voxels for image representation in iterative reconstruction algorithms.

R M Lewitt1.   

Abstract

Spherically symmetric volume elements are alternatives to the more conventional voxels for the construction of volume images in the computer. The image representation, and the calculation of projections of it, are essential components of iterative algorithms for image reconstruction from projection data. A two-parameter family of spherical volume elements is described that allows control of the smoothness properties of the represented image, whereas conventional voxels are discontinuous. The rotational symmetry of the spherical elements leads to efficient calculation of projections of the represented image, as required in iterative reconstruction algorithms. For volume elements whose shape is ellipsoidal (rather than spherical) it is shown that efficient calculation of the projections is also possible by means of an image space transformation.

Mesh:

Year:  1992        PMID: 1565698     DOI: 10.1088/0031-9155/37/3/015

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  19 in total

1.  On the computational implementation of forward and back-projection operations for cone-beam computed tomography.

Authors:  Davood Karimi; Rabab Ward
Journal:  Med Biol Eng Comput       Date:  2015-10-05       Impact factor: 2.602

2.  Technical Note: FreeCT_ICD: An open-source implementation of a model-based iterative reconstruction method using coordinate descent optimization for CT imaging investigations.

Authors:  John M Hoffman; Frédéric Noo; Stefano Young; Scott S Hsieh; Michael McNitt-Gray
Journal:  Med Phys       Date:  2018-06-01       Impact factor: 4.071

3.  Imaging studies for evaluating impact of position sampling techniques in PET scanners.

Authors:  Suleman Surti; Matthew E Werner; Joel S Karp
Journal:  IEEE Trans Nucl Sci       Date:  2010-10-01       Impact factor: 1.679

4.  Optimization-based reconstruction of sparse images from few-view projections.

Authors:  Xiao Han; Junguo Bian; Erik L Ritman; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-07-31       Impact factor: 3.609

5.  Pre-computed system matrix calculation based on a piece-wise method for PET.

Authors:  Abdella M Ahmed; Yohei Kikuchi; Shigeo Matsuyama; Atsuki Terakawa; Sodai Takyu; Hiroyuki Sugai; Keizo Ishii
Journal:  Radiol Phys Technol       Date:  2014-09-26

6.  An imaging model incorporating ultrasonic transducer properties for three-dimensional optoacoustic tomography.

Authors:  Kun Wang; Sergey A Ermilov; Richard Su; Hans-Peter Brecht; Alexander A Oraevsky; Mark A Anastasio
Journal:  IEEE Trans Med Imaging       Date:  2010-09-02       Impact factor: 10.048

7.  Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

Authors:  Xiaochuan Pan; Emil Y Sidky; Michael Vannier
Journal:  Inverse Probl       Date:  2009-01-01       Impact factor: 2.407

8.  Filtered backprojection implementation of the immediately-after-backprojection filtering.

Authors:  Gengsheng L Zeng
Journal:  Biomed Phys Eng Express       Date:  2018-06-13

9.  Discrete imaging models for three-dimensional optoacoustic tomography using radially symmetric expansion functions.

Authors:  Kun Wang; Robert W Schoonover; Richard Su; Alexander Oraevsky; Mark A Anastasio
Journal:  IEEE Trans Med Imaging       Date:  2014-05       Impact factor: 10.048

10.  The imaging performance of a LaBr3-based PET scanner.

Authors:  M E Daube-Witherspoon; S Surti; A Perkins; C C M Kyba; R Wiener; M E Werner; R Kulp; J S Karp
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.