Literature DB >> 15650064

Six and 12 months' evaluation of a self-etching primer versus two-stage etch and prime for orthodontic bonding: a randomized clinical trial.

Y D Aljubouri1, D T Millett, W H Gilmour.   

Abstract

The aim of the study was to compare the mean clinical chair-side time required for bracket bonding and the mean bond failure rate at 6 and 12 months of stainless steel brackets with a micro-etched base bonded with a light-cured composite using a self-etching primer (SEP) or a two-stage etch and prime system.Fifty-one subjects who required upper and/or lower pre-adjusted edgewise fixed appliances were recruited in a single centre randomized clinical trial. The trial was a single-blind design, involving a within-patient comparison of the two bonding systems with each patient randomly allocated the two bonding systems for each side of the mouth (all teeth except molars). The two bonding techniques used were standardized throughout the trial and all bracket bonding was performed by a single operator. Bonding time was recorded using a digital timer. The bond failure rate of a strictly paired sample was recorded at 6 and 12 months for each patient. The mean bracket bonding time per patient with the SEP was significantly less than that with the two-stage bonding system (mean difference 24.9 seconds; 95 per cent confidence interval 22.1-27.7 seconds; paired t-test P < 0.001). The overall bond failure rates at 6 and 12 months with the SEP were 0.8 and 1.6 per cent, respectively, and for the two-stage etch and prime 1.1 and 3.1 per cent, respectively. At 6 months, the mean bond failure rate per patient with the SEP was 0.81 per cent and with the two-stage bonding system 0.96 per cent (P = 0.87; Wilcoxon signed rank test). At 12 months, the mean bond failure rate with the SEP per patient was 1.54 per cent and with the two-stage bonding system 2.78 per cent (P = 0.33; Wilcoxon signed rank test). The mean bracket bonding time with the SEP per patient was significantly shorter than that of the two-stage bonding system (P < 0.001). The difference between the overall bond failure rate and the mean bond failure rate per patient for the two bonding systems was not statistically nor clinically significant at 6 and 12 months (P = 1.00 and P = 0.125, respectively; McNemar's test).

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15650064     DOI: 10.1093/ejo/26.6.565

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  11 in total

1.  Optimal enamel conditioning strategy for rebonding orthodontic brackets: a laboratory study.

Authors:  Qi-Feng Zhang; Hua Yao; Zhi-Yong Li; Li Jin; Hui-Ming Wang
Journal:  Int J Clin Exp Med       Date:  2014-09-15

2.  Clinical performance of precoated brackets and self-etch bonding technique: a prospective comparative study.

Authors:  Ezgi Atik; Hande Gorucu-Coskuner; Tulin Taner
Journal:  Clin Oral Investig       Date:  2018-11-30       Impact factor: 3.573

3.  Comparative Evaluation of Two Bis-GMA Based Orthodontic Bonding Adhesives - A Randomized Clinical Trial.

Authors:  Christine Samantha; Shantha Sundari; Shyamala Chandrasekhar; Gautham Sivamurty; Saravana Dinesh
Journal:  J Clin Diagn Res       Date:  2017-04-01

4.  The effects of application time of a self-etching primer and debonding methods on bracket bond strength.

Authors:  Brandon C Parrish; Thomas R Katona; Serkis C Isikbay; Kelton T Stewart; Katherine S Kula
Journal:  Angle Orthod       Date:  2011-07-28       Impact factor: 2.079

Review 5.  Enamel etching for bonding fixed orthodontic braces.

Authors:  Haikun Hu; Chunjie Li; Fan Li; Jianwei Chen; Jianfeng Sun; Shujuan Zou; Andrew Sandham; Qiang Xu; Philip Riley; Qingsong Ye
Journal:  Cochrane Database Syst Rev       Date:  2013-11-25

Review 6.  Adhesives for bonded molar tubes during fixed brace treatment.

Authors:  Declan T Millett; Nicky A Mandall; Rye Cr Mattick; Joy Hickman; Anne-Marie Glenny
Journal:  Cochrane Database Syst Rev       Date:  2017-02-23

7.  Effects of procedures of remineralization around orthodontics bracket bonded by self-etching primer on its shear bond strength.

Authors:  Mahmoud Al-Suleiman; Nick Silikas; David Watts
Journal:  J Orthod Sci       Date:  2012-07

8.  The influence of adding modified zirconium oxide-titanium dioxide nano-particles on mechanical properties of orthodontic adhesive: an in vitro study.

Authors:  Nayef H Felemban; Mohamed I Ebrahim
Journal:  BMC Oral Health       Date:  2017-01-13       Impact factor: 2.757

9.  Comparison of shear bond strength and enamel surface changing between the two-step etching and primer and self-etch primer methods in rebonding of orthodontic brackets: An in vitro study.

Authors:  Shiva Alavi; Ailin Ehteshami
Journal:  Dent Res J (Isfahan)       Date:  2019 Jul-Aug

10.  Clinical bond failure rates of adhesive precoated self-ligating brackets using a self-etching primer.

Authors:  Mete Ozer; Mehmet Bayram; Cagri Dincyurek; Fuat Tokalak
Journal:  Angle Orthod       Date:  2013-07-02       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.