Literature DB >> 28230910

Adhesives for bonded molar tubes during fixed brace treatment.

Declan T Millett1, Nicky A Mandall2, Rye Cr Mattick3, Joy Hickman4, Anne-Marie Glenny5.   

Abstract

BACKGROUND: Orthodontic treatment involves using fixed or removable appliances (dental braces) to correct the positions of teeth. The success of a fixed appliance depends partly on the metal attachments (brackets and bands) being glued to the teeth so that they do not become detached during treatment. Brackets (metal squares) are usually attached to teeth other than molars, where bands (metal rings that go round each tooth) are more commonly used. Orthodontic tubes (stainless steel tubes that allow wires to pass through them), are typically welded to bands but they may also be glued directly (bonded) to molars. Failure of brackets, bands and bonded molar tubes slows down the progress of treatment with a fixed appliance. It can also be costly in terms of clinical time, materials and time lost from education/work for the patient. This is an update of the Cochrane review first published in 2011. A new full search was conducted on 15 February 2017 but no new studies were identified. We have only updated the search methods section in this new version. The conclusions of this Cochrane review remain the same.
OBJECTIVES: To evaluate the effectiveness of the adhesives used to attach bonded molar tubes, and the relative effectiveness of the adhesives used to attach bonded molar tubes versus adhesives used to attach bands, during fixed appliance treatment, in terms of: (1) how often the tubes (or bands) come off during treatment; and (2) whether they protect the bonded (or banded) teeth against decay. SEARCH
METHODS: The following electronic databases were searched: Cochrane Oral Health's Trials Register (to 15 February 2017), the Cochrane Central Register of Controlled Trials (CENTRAL; 2017, Issue 1) in the Cochrane Library (searched 15 February 2017), MEDLINE Ovid (1946 to 15 February 2017), and Embase Ovid (1980 to 15 February 2017). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. SELECTION CRITERIA: Randomised controlled trials of participants with full arch fixed orthodontic appliance(s) with molar tubes, bonded to first or second permanent molars. Trials which compared any type of adhesive used to bond molar tubes (stainless steel or titanium) with any other adhesive, were included.Trials were also included where:(1) a tube was bonded to a molar tooth on one side of an arch and a band cemented to the same tooth type on the opposite side of the same arch;(2) molar tubes had been allocated to one tooth type in one patient group and molar bands to the same tooth type in another patient group. DATA COLLECTION AND ANALYSIS: The selection of papers, decision about eligibility and data extraction were carried out independently and in duplicate without blinding to the authors, adhesives used or results obtained. All disagreements were resolved by discussion. MAIN
RESULTS: Two trials (n = 190), at low risk of bias, were included in the review and both presented data on first time failure at the tooth level. Pooling of the data showed a statistically significant difference in favour of molar bands, with a hazard ratio of 2.92 (95% confidence intervals (CI) 1.80 to 4.72). No statistically significant heterogeneity was shown between the two studies. Data on first time failure at the patient level were also available and showed statistically different difference in favour of molar bands (risk ratio 2.30; 95% CI 1.56 to 3.41) (risk of event for molar tubes = 57%; risk of event for molar bands 25%).One trial presented data on decalcification again showing a statistically significant difference in favour of molar bands. No other adverse events identified. AUTHORS'
CONCLUSIONS: From the two well-designed and low risk of bias trials included in this review it was shown that the failure of molar tubes bonded with either a chemically-cured or light-cured adhesive was considerably higher than that of molar bands cemented with glass ionomer cement. One trial indicated that there was less decalcification with molar bands cemented with glass ionomer cement than with bonded molar tubes cemented with a light-cured adhesive. However, given there are limited data for this outcome, further evidence is required to draw more robust conclusions.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28230910      PMCID: PMC6464028          DOI: 10.1002/14651858.CD008236.pub3

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  36 in total

Review 1.  Orthodontic adhesives: a systematic review.

Authors:  N A Mandall; D T Millett; C R Mattick; J Hickman; H V Worthington; T V Macfarlane
Journal:  J Orthod       Date:  2002-09

2.  Long-term clinical failure rate of molar tubes bonded with a self-etching primer.

Authors:  Nikolaos Pandis; Lars Christensen; Theodore Eliades
Journal:  Angle Orthod       Date:  2005-11       Impact factor: 2.079

Review 3.  Adhesives for fixed orthodontic bands.

Authors:  D T Millett; A M Glenny; C R Mattick; J Hickman; N A Mandall
Journal:  Cochrane Database Syst Rev       Date:  2007-04-18

4.  2008 JCO study of orthodontic diagnosis and treatment procedures, part 1: results and trends.

Authors:  Robert G Keim; Eugene L Gottlieb; Allen H Nelson; David S Vogels
Journal:  J Clin Orthod       Date:  2008-11

5.  2008 JCO Study of Orthodontic Diagnosis and Treatment Procedures. Part 2: breakdowns of selected variables.

Authors:  Robert G Keim; Eugene L Gottlieb; Allen H Nelson; David S Vogels
Journal:  J Clin Orthod       Date:  2008-12

6.  Bonding to molars--the effect of etch time (an in vitro study).

Authors:  C D Johnston; D J Burden; D L Hussey; C A Mitchell
Journal:  Eur J Orthod       Date:  1998-04       Impact factor: 3.075

7.  Orthodontic status and treatment need of 12-year-old children in South Africa using the Dental Aesthetic Index.

Authors:  P J van Wyk; R J Drummond
Journal:  SADJ       Date:  2005-09

8.  Bonded molar tubes: a retrospective evaluation of clinical performance.

Authors:  D T Millett; A Hallgren; A C Fornell; M Robertson
Journal:  Am J Orthod Dentofacial Orthop       Date:  1999-06       Impact factor: 2.650

9.  Orthodontics in the general dental service of England and Wales: a critical assessment of standards.

Authors:  S Richmond; W C Shaw; C D Stephens; W G Webb; C T Roberts; M Andrews
Journal:  Br Dent J       Date:  1993-05-08       Impact factor: 1.626

10.  Orthodontic treatment need in Spanish schoolchildren: an epidemiological study using the Index of Orthodontic Treatment Need.

Authors:  David Manzanera; José María Montiel-Company; José Manuel Almerich-Silla; José Luis Gandía
Journal:  Eur J Orthod       Date:  2008-12-08       Impact factor: 3.075

View more
  1 in total

1.  Impact of temperature changes to the adhesion strength of molar tubes: an in vitro study.

Authors:  Benedikta Palesik; Kotryna Šileikytė; Julius Griškevičius; Rimantas Stonkus; Antanas Šidlauskas; Kristina Lopatienė
Journal:  BMC Oral Health       Date:  2022-04-08       Impact factor: 2.757

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.