Literature DB >> 15649761

Aqueous flat-cells perpendicular to the electric field for use in electron paramagnetic resonance spectroscopy, II: design.

Jason W Sidabras1, Richard R Mett, James S Hyde.   

Abstract

This paper builds on the work of Mett and Hyde [J. Magn. Reson. 165 (2003) 137]. Various aqueous flat-cell geometries in the perpendicular orientation have been studied using Ansoft High Frequency Structure Simulator (version 9.0, Pittsburgh, PA) and Computer Simulation Technology Microwave Studio (version 5.0, Wellesley Hills, MA). The analytic theory of Mett and Hyde has been refined to predict optimum dimensions of multiple sample cell structures including the effect of the sample holder dielectric properties and the interaction of the cells with each other on EPR signal strength. From these calculations and simulations we propose a practical multiple cell sample structure for use in commercial rectangular TE102 cavities that yields 2.0-2.3 times higher sensitivity relative to a single flat-cell in the nodal orientation. We also describe a modified TE102 resonator design with square rather than cylindrical sample-access stacks that is predicted to give a factor of 2.2-2.7 enhancement in EPR signal strength of a single flat-cell in the nodal orientation. These signal enhancements are predicted with sample holders fabricated from polytetrafluoroethylene. Additional improvement in EPR signal of up to 75% can be achieved by using sample holder materials with lower dielectric constants.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15649761     DOI: 10.1016/j.jmr.2004.11.006

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  5 in total

1.  Thermo-mechanical analysis of a probe for electron paramagnetic resonance spectroscopy operating at cryogenic temperatures.

Authors:  Bodhayan Dev; Charan Raj Gujjala; Thorsten Maly
Journal:  Rev Sci Instrum       Date:  2019-04       Impact factor: 1.523

2.  Extruded dielectric sample tubes of complex cross section for EPR signal enhancement of aqueous samples.

Authors:  Jason W Sidabras; Richard R Mett; James S Hyde
Journal:  J Magn Reson       Date:  2017-02-14       Impact factor: 2.229

3.  Rutile dielectric loop-gap resonator for X-band EPR spectroscopy of small aqueous samples.

Authors:  Richard R Mett; Jason W Sidabras; James R Anderson; Candice S Klug; James S Hyde
Journal:  J Magn Reson       Date:  2019-08-28       Impact factor: 2.229

4.  EPR UNIFORM FIELD SIGNAL ENHANCEMENT BY DIELECTRIC TUBES IN CAVITIES.

Authors:  James S Hyde; Richard R Mett
Journal:  Appl Magn Reson       Date:  2017-09-18       Impact factor: 0.831

5.  Autobiography of James S. Hyde.

Authors:  James S Hyde
Journal:  Appl Magn Reson       Date:  2017-10-27       Impact factor: 0.831

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.