Literature DB >> 28226294

Extruded dielectric sample tubes of complex cross section for EPR signal enhancement of aqueous samples.

Jason W Sidabras1, Richard R Mett2, James S Hyde3.   

Abstract

This paper builds on the work of Mett and Hyde (2003) and Sidabras et al. (2005) where multiple flat aqueous sample cells placed perpendicular to electric fields in microwave cavities were used to reduce the RF losses and increase the EPR signal. In this work, we present three novel sample holders for loop-gap resonators (LGRs) and cylindrical cavity geometries. Two sample holders have been commissioned and built by polytetrafluoroethylene (PTFE) extrusion techniques: a 1mm O.D. capillary with a septum down the middle, named DoubleDee, and a 3.5mm O.D. star shaped sample holder, named AquaStar. Simulations and experimental results at X-band show that the EPR signal intensity increases by factors of 1.43 and 3.87 in the DoubleDee and AquaStar respectively, over the current TPX 0.9mm O.D. sample tube in a two-loop-one-gap LGR. Finally, combining the insight gained from the constructed sample holders and finite-element solutions, a third multi-lumen sample holder for a cylindrical TE011 cavity is optimized, named AquaSun, where simulations show an EPR signal intensity increase by a factor of 8.2 over a standard 1mm capillary.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Aqueous samples; Cylindrical symmetry; Electron paramagnetic resonance; Loop-gap resonator; Multi-lumen sample holders

Mesh:

Substances:

Year:  2017        PMID: 28226294      PMCID: PMC5674976          DOI: 10.1016/j.jmr.2017.02.009

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  5 in total

1.  Site-directed spin labeling of proteins. Applications to diphtheria toxin.

Authors:  K J Oh; C Altenbach; R J Collier; W L Hubbell
Journal:  Methods Mol Biol       Date:  2000

2.  Aqueous flat cells perpendicular to the electric field for use in electron paramagnetic resonance spectroscopy.

Authors:  Richard R Mett; James S Hyde
Journal:  J Magn Reson       Date:  2003-11       Impact factor: 2.229

3.  Aqueous sample in an EPR cavity: sensitivity considerations.

Authors:  Yuri E Nesmelov; Anand Gopinath; David D Thomas
Journal:  J Magn Reson       Date:  2004-03       Impact factor: 2.229

4.  Multibore sample cell increases EPR sensitivity for aqueous samples.

Authors:  Yuri E Nesmelov; David D Thomas
Journal:  J Magn Reson       Date:  2005-11-10       Impact factor: 2.229

5.  Aqueous flat-cells perpendicular to the electric field for use in electron paramagnetic resonance spectroscopy, II: design.

Authors:  Jason W Sidabras; Richard R Mett; James S Hyde
Journal:  J Magn Reson       Date:  2005-02       Impact factor: 2.229

  5 in total
  4 in total

1.  Lipopolysaccharide binding to the periplasmic protein LptA.

Authors:  Kathryn M Schultz; Tanner J Lundquist; Candice S Klug
Journal:  Protein Sci       Date:  2017-04-30       Impact factor: 6.725

2.  Disruption of the E. coli LptC dimerization interface and characterization of lipopolysaccharide and LptA binding to monomeric LptC.

Authors:  Kathryn M Schultz; Matthew A Fischer; Elizabeth L Noey; Candice S Klug
Journal:  Protein Sci       Date:  2018-05-09       Impact factor: 6.725

3.  Characterization of and lipopolysaccharide binding to the E. coli LptC protein dimer.

Authors:  Kathryn M Schultz; Candice S Klug
Journal:  Protein Sci       Date:  2017-10-28       Impact factor: 6.725

4.  Autobiography of James S. Hyde.

Authors:  James S Hyde
Journal:  Appl Magn Reson       Date:  2017-10-27       Impact factor: 0.831

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.