Literature DB >> 15643533

Comparison of Polar 810s and an ambulatory ECG system for RR interval measurement during progressive exercise.

M Kingsley1, M J Lewis, R E Marson.   

Abstract

Ambulatory heart rate monitors and clinical electrocardiographic (ECG) devices are capable of measuring the length of consecutive cardiac periods (RR intervals). The aim of the study was to assess the agreement between the Polar 810s heart rate monitor (Polar) and the Reynolds digital ambulatory ECG using Pathfinder software version 8.4 (Reynolds v8.4) during cycle ergometry. For this purpose, eight subjects completed incremental cycling exercise that began at 60 W and increased by 30 W each 2-minute period until volitional fatigue. Simultaneous recording of the ECG (Reynolds Pathfinder), RR interval (Polar), and respiratory parameters (Metamax 3B) were undertaken at rest and throughout the exercise period. No significant differences were found in RR intervals measured by Polar and Reynolds v8.4 at any relative intensity. Polar and Reynolds v8.4 displayed strong linear relationships at all relative intensities (r2=0.927 to 0.998). Bland and Altman analyses between Polar and Reynolds v8.4 consistently demonstrated minimal bias in absolute RR interval (<0.10 ms) and the limits of agreement for group differences in RR interval and heart rate were less than +/- 10 ms and +/- 2 beats.min (-1) for all relative intensities, respectively. Power spectral analysis provided similar results for both systems in all bandwidths studied during rest and low intensity exercise. However, significant differences and large relative limits of agreement (>100 % of mean of paired means) were identified in UF at intensities > 40 % VO2max, HF at intensities > 60 % VO2max and LF during exercise at 80-100 % VO2max. These findings demonstrate that RR intervals and heart rate measurements obtained using Polar and Reynolds v8.4 are in good agreement. However, caution should be exercised when interpreting spectral analysis of RR interval data derived from different acquisition systems during physical activity.

Entities:  

Mesh:

Year:  2005        PMID: 15643533     DOI: 10.1055/s-2004-817878

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  44 in total

1.  Arousal and activity choice in autism: A single case assessment integrating autonomic and behavioral analysis.

Authors:  John Hoch; Tim Moore; Jennifer McComas; Frank J Symons
Journal:  J Appl Biobehav Res       Date:  2010-09

Review 2.  [Options and limitations of heart rate measurement and analysis of heart rate variability by mobile devices: A systematic review].

Authors:  Stefan Sammito; Irina Böckelmann
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2016-02-10

3.  Estimation of maximal heart rate using the relationship between heart rate variability and exercise intensity in 40-67 years old men.

Authors:  Laura Karavirta; Mikko P Tulppo; Kai Nyman; David E Laaksonen; Teemu Pullinen; Raija T Laukkanen; Hannu Kinnunen; Arja Häkkinen; Keijo Häkkinen
Journal:  Eur J Appl Physiol       Date:  2008-01-11       Impact factor: 3.078

4.  Effect of high intensity intermittent training on heart rate variability in prepubescent children.

Authors:  François-Xavier Gamelin; Georges Baquet; Serge Berthoin; Delphine Thevenet; Cedric Nourry; Stéphane Nottin; Laurent Bosquet
Journal:  Eur J Appl Physiol       Date:  2008-12-24       Impact factor: 3.078

5.  Bioharness(™) multivariable monitoring device: part. I: validity.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-09-01       Impact factor: 2.988

6.  Effects of an extreme endurance race on energy balance and body composition - a case study.

Authors:  Stefan Bircher; Andreas Enggist; Thomas Jehle; Beat Knechtle
Journal:  J Sports Sci Med       Date:  2006-03-01       Impact factor: 2.988

7.  Field based reliability and validity of the bioharness™ multivariable monitoring device.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew C S Mitchell; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-12-01       Impact factor: 2.988

8.  Levels of agreement for RR intervals and short-term heart rate variability obtained from the Polar S810 and an alternative system.

Authors:  David Nunan; Djordje G Jakovljevic; Gay Donovan; Lynette D Hodges; Gavin R H Sandercock; David A Brodie
Journal:  Eur J Appl Physiol       Date:  2008-04-22       Impact factor: 3.078

9.  Importance of tachogram length and period of recording during noninvasive investigation of the autonomic nervous system.

Authors:  Catharina C Grant; Dina C J van Rensburg; Nina Strydom; Margaretha Viljoen
Journal:  Ann Noninvasive Electrocardiol       Date:  2011-04       Impact factor: 1.468

10.  Improbable effect of carbohydrate diet on cardiac autonomic modulation during exercise.

Authors:  Martin Buchheit; Alberto Mendez-Villanueva
Journal:  Eur J Appl Physiol       Date:  2010-02-12       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.