Literature DB >> 15637481

A real-time 3-dimensional digital Doppler method for measurement of flow rate and volume through mitral valve in children: a validation study compared with magnetic resonance imaging.

Shuping Ge1, Liping Bu, Honghai Zhang, Erik Schelbert, Michelle Disterhoft, Xiangning Li, Xiaokui Li, David Sahn, Alan Stolpen, Milan Sonka.   

Abstract

We developed and assessed a real-time 3-dimensional (3D) digital Doppler method for measurement of flow volumes through the mitral valve in children. A total of 13 children (aged 10.46 +/- 2.5 years; 8 boys/5 girls) were enrolled. An ultrasound system (Sonos 7500, Philips, Andover, Mass) was used to acquire raw 3D velocity data for flow measurement based on Gaussian control surface theorem [flow (mL/s) = mean velocity x flow area]. Stroke volume (SV) measured by real-time 3D digital Doppler with the control surface at the mitral valve annulus or orifice was compared with the SV by phase velocity cine magnetic resonance imaging (MRI) at the ascending aorta and by left ventricular volumetric MRI measurement. The best correlation and agreement were seen at the mitral valve orifice by real-time 3D digital Doppler compared with SV by phase velocity cine MRI at the ascending aorta (r = 0.92, mean difference = -5.2 +/- 12.0 mL) and SV by left ventricular volumetric MRI measurement (r = 0.94, mean difference = -0.2 +/- 10.3 mL).

Entities:  

Mesh:

Year:  2005        PMID: 15637481     DOI: 10.1016/j.echo.2004.08.021

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  5 in total

Review 1.  Quantitative assessment of mitral insufficiency: its advantages and disadvantages.

Authors:  Anna Paszczuk; Susan E Wiegers
Journal:  Heart Fail Rev       Date:  2006-09       Impact factor: 4.214

2.  Carotid stenosis assessed with a 4-dimensional semiautomated Doppler system.

Authors:  Flemming Forsberg; Alan D Stein; Daniel A Merton; Kathryn J Lipcan; Donald Herzog; Laurence Parker; Laurence Needleman
Journal:  J Ultrasound Med       Date:  2008-09       Impact factor: 2.153

3.  Automated quantification of mitral regurgitation by three dimensional real time full volume color Doppler transthoracic echocardiography: a validation with cardiac magnetic resonance imaging and comparison with two dimensional quantitative methods.

Authors:  Jang-Won Son; Hyuk-Jae Chang; Jin-Kyung Lee; Hee-Jung Chung; Ran-Young Song; Young-Jin Kim; Saurabh Datta; Ran Heo; Sang-Hoon Shin; In-Jeong Cho; Chi Young Shim; Geu-Ru Hong; Namsik Chung
Journal:  J Cardiovasc Ultrasound       Date:  2013-06-26

4.  Validation study of the accuracy of echocardiographic measurements of systemic blood flow volume in newborn infants.

Authors:  Benjamim Ficial; Anna E Finnemore; David J Cox; Kathryn M Broadhouse; Anthony N Price; Giuliana Durighel; Georgia Ekitzidou; Joseph V Hajnal; A David Edwards; Alan M Groves
Journal:  J Am Soc Echocardiogr       Date:  2013-09-26       Impact factor: 5.251

Review 5.  Advanced echocardiographic techniques.

Authors:  Rebecca Perry; Majo Joseph
Journal:  Australas J Ultrasound Med       Date:  2015-12-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.