Literature DB >> 1562764

Cardiac ejection fraction: phantom study comparing cine MR imaging, radionuclide blood pool imaging, and ventriculography.

J F Debatin1, S N Nadel, J F Paolini, H D Sostman, R E Coleman, A J Evans, C Beam, C E Spritzer, T M Bashore.   

Abstract

The accuracy and reproducibility of cardiac ejection fraction (EF) measurements based on cine magnetic resonance (MR) imaging, radionuclide multigated acquisition (MUGA) blood pool imaging, and angiographic ventriculography were evaluated by comparing them with a volumetrically determined standard. A biventricular, compliant, fluid-filled heart phantom was developed to mimic normal cardiac anatomy and physiology. Ventricular EFs were measured with cine MR imaging by summation of nine contiguous 10-mm-thick sections in short and long axis, with single-plane ventriculography, and with MUGA. Three measurements were performed with each modality for each of three EFs. Ventriculography was least accurate, with average relative errors ranging from 7.9% for the largest EF to 60.1% for the smallest. Cine MR was most accurate, with average relative errors ranging from 4.4% to 8.5%. MUGA EF measurements showed good correlation, with average relative errors ranging from 7.1% to 22.4%. Comparison of the error variances for the three modalities with the F test revealed that MR and MUGA EF measurements were significantly more accurate than those based on ventriculography (P less than .01). No significant difference was demonstrated between the accuracy of short- and long-axis cine MR acquisitions.

Mesh:

Year:  1992        PMID: 1562764     DOI: 10.1002/jmri.1880020205

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  14 in total

Review 1.  MRI in coronary artery disease.

Authors:  Jörg Barkhausen; Peter Hunold; Kai-Uwe Waltering
Journal:  Eur Radiol       Date:  2004-09-04       Impact factor: 5.315

2.  Assessment of global left ventricular functional parameters: analysis of every second short-axis Magnetic Resonance Imaging slices is as accurate as analysis of consecutive slices.

Authors:  Daniel D Lubbers; Tineke P Willems; Pieter A van der Vleuten; Jelle Overbosch; Marco J W Götte; Dirk J van Veldhuisen; Matthijs Oudkerk
Journal:  Int J Cardiovasc Imaging       Date:  2007-06-28       Impact factor: 2.357

3.  Comparative evaluation of active contour model extensions for automated cardiac MR image segmentation by regional error assessment.

Authors:  Duy Nguyen; Karen Masterson; Jean-Paul Vallée
Journal:  MAGMA       Date:  2007-03-06       Impact factor: 2.310

Review 4.  Cardiotoxicity due to chemotherapy: role of cardiac imaging.

Authors:  Frédéric Poulin; Paaladinesh Thavendiranathan
Journal:  Curr Cardiol Rep       Date:  2015-03       Impact factor: 2.931

Review 5.  Magnetic resonance imaging in the assessment of ventricular remodeling and viability.

Authors:  Michael Jerosch-Herold; Raymond Y Kwong
Journal:  Curr Heart Fail Rep       Date:  2008-03

Review 6.  Ultra-high-speed MR imaging.

Authors:  C P Davis; G C McKinnon; J F Debatin; G K von Schulthess
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

Review 7.  Evaluation of left ventricular function using cardiac magnetic resonance imaging.

Authors:  Suchi Grover; Darryl P Leong; Joseph B Selvanayagam
Journal:  J Nucl Cardiol       Date:  2011-04       Impact factor: 5.952

8.  Pediatric cardiac MRI: automated left-ventricular volumes and function analysis and effects of manual adjustments.

Authors:  Matthias Hammon; Rolf Janka; Peter Dankerl; Martin Glöckler; Ferdinand J Kammerer; Sven Dittrich; Michael Uder; Oliver Rompel
Journal:  Pediatr Radiol       Date:  2014-11-19

9.  Frequent MUGA testing in a myeloma patient: A case-based ethics discussion.

Authors:  Sabha Bhatti; Robert C Hendel; Juan Lopez-Mattei; Ronald G Schwartz; Gilbert Raff; Andrew J Einstein
Journal:  J Nucl Cardiol       Date:  2016-06-06       Impact factor: 5.952

10.  Left ventricular quantification with breath-hold MR imaging: comparison with echocardiography.

Authors:  J G Bogaert; H T Bosmans; F E Rademakers; E P Bellon; M C Herregods; J A Verschakelen; F Van de Werf; G J Marchal
Journal:  MAGMA       Date:  1995-03       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.