Literature DB >> 17340125

Comparative evaluation of active contour model extensions for automated cardiac MR image segmentation by regional error assessment.

Duy Nguyen1, Karen Masterson, Jean-Paul Vallée.   

Abstract

OBJECTIVE: In the field of cardiac MR image segmentation, active contour models, or snakes have been extensively used, owing to their promising results and to the numerous extensions proposed to improve their performance. This paper explores a methodology for evaluating cardiac MR image segmentation algorithms, which assesses the distance between computer-generated and the observer's hand-outlined boundaries. This metric was applied to various external force extensions of the traditional snake, since no systematic comparison has been performed.
MATERIALS AND METHODS: Cardiac MRI from six patients were analyzed. Imaging was performed on a 1.5 T MR scanner with ECG-gated balanced steady-state free precession (b-SSFP) sequences. Segmentation performances were established for traditional snake, gradient vector flow snake, standard- and guided- pressure force-based snake. The use of a pre-treatment with non-linear anisotropic filtering was also compared to non-filtered images.
RESULTS: Agreement between manual and segmentation algorithms was satisfactory for ejection fraction for every segmentation scheme. However end-systolic and end-diastolic volumes were systematically underestimated.
CONCLUSION: The developed regional error metric provided a more rigorous evaluation of the segmentation schemes in comparison to the classical derived parameters based on left ventricle volume estimation, usually used in functional cardiac MR studies. These derived parameters can furthermore mask local segmentation errors.

Entities:  

Mesh:

Year:  2007        PMID: 17340125     DOI: 10.1007/s10334-007-0069-z

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  39 in total

1.  Knowledge-based tensor anisotropic diffusion of cardiac magnetic resonance images.

Authors:  G I Sanchez-Ortiz; D Rueckert; P Burger
Journal:  Med Image Anal       Date:  1999-03       Impact factor: 8.545

Review 2.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Circulation       Date:  2002-01-29       Impact factor: 29.690

3.  Which standard has the gold?

Authors:  C B Higgins
Journal:  J Am Coll Cardiol       Date:  1992-06       Impact factor: 24.094

4.  Snakes, shapes, and gradient vector flow.

Authors:  C Xu; J L Prince
Journal:  IEEE Trans Image Process       Date:  1998       Impact factor: 10.856

5.  Contour extraction from cardiac MRI studies using snakes.

Authors:  S Ranganath
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

6.  Wavelet-based Rician noise removal for magnetic resonance imaging.

Authors:  R D Nowak
Journal:  IEEE Trans Image Process       Date:  1999       Impact factor: 10.856

7.  Automatic ventricular cavity boundary detection from sequential ultrasound images using simulated annealing.

Authors:  N Friedland; D Adam
Journal:  IEEE Trans Med Imaging       Date:  1989       Impact factor: 10.048

8.  Maximum-likelihood estimation of Rician distribution parameters.

Authors:  J Sijbers; A J den Dekker; P Scheunders; D Van Dyck
Journal:  IEEE Trans Med Imaging       Date:  1998-06       Impact factor: 10.048

9.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

10.  Automated myocardial edge detection from breath-hold cine-MR images: evaluation of left ventricular volumes and mass.

Authors:  C Baldy; P Douek; P Croisille; I E Magnin; D Revel; M Amiel
Journal:  Magn Reson Imaging       Date:  1994       Impact factor: 2.546

View more
  1 in total

1.  A Novel Gradient Vector Flow Snake Model Based on Convex Function for Infrared Image Segmentation.

Authors:  Rui Zhang; Shiping Zhu; Qin Zhou
Journal:  Sensors (Basel)       Date:  2016-10-21       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.