Corrosion at the marginal gap of implant-supported suprastructures and implant failure.

Joseph S Guindy1, Harold Schiel, Fre Schmidli, Jakob Wirz.   

Abstract

PURPOSE: Late failure, which occurs after successful osseointegration, is usually attributed to prosthodontic determinants. Corrosion of metallic suprastructures and incorrectly handled materials are often primary causes of late implant failure. In this study, 6 implants whose failure was related to suprastructure metal corrosion and adjacent bone were investigated.
MATERIALS AND METHODS: Six implants as well as their suprastructures were analyzed for surface corrosion using light and scanning microscopy. Metal alloys and soldering compounds were analyzed using energy-dispersive x-ray analysis. Bone adhering to the implants was removed and analyzed for metal content using atom absorption spectroscopy.
RESULTS: Extensive corrosion lesions and areas of oxidation were detected on all 6 of the implants and inner crown surfaces. Bone tissue collected from 5 of the implants showed higher contents of metal ions in comparison to physiologic baseline values detected in healthy bone. DISCUSSION: In spite of the high gold content of the suprastructure, corrosion occurred. Bonding oxides necessary for the process of fusing porcelain to gold will initiate corrosion. Apparently, once corrosion is initiated it rapidly progresses at the gap crevices, and toxic metal ions are released. These toxic ions diffuse into the peri-implant bone, causing bone structure breakdown and hastening osseodisintegration.
CONCLUSION: Biocompatible metals, alloys, and ceramics should be used for implant-supported suprastructures. It is also essential that gaps between the implant and its suprastructure be avoided by cementing the suprastructure or sealing the gap.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15623057

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  8 in total

Review 1.  Corrosion of Metallic Biomaterials: A Review.

Authors:  Noam Eliaz
Journal:  Materials (Basel)       Date:  2019-01-28       Impact factor: 3.623

2.  Complete mechanical characterization of an external hexagonal implant connection: in vitro study, 3D FEM, and probabilistic fatigue.

Authors:  María Prados-Privado; Sérgio A Gehrke; Rosa Rojo; Juan Carlos Prados-Frutos
Journal:  Med Biol Eng Comput       Date:  2018-06-11       Impact factor: 2.602

Review 3.  Metallic ions as therapeutic agents in tissue engineering scaffolds: an overview of their biological applications and strategies for new developments.

Authors:  Viviana Mouriño; Juan Pablo Cattalini; Aldo R Boccaccini
Journal:  J R Soc Interface       Date:  2011-12-07       Impact factor: 4.118

4.  Tantalum Nitride-Decorated Titanium with Enhanced Resistance to Microbiologically Induced Corrosion and Mechanical Property for Dental Application.

Authors:  Yifei Zhang; Yunfei Zheng; Yongliang Li; Lixin Wang; Yanjie Bai; Qiang Zhao; Xiaoling Xiong; Yan Cheng; Zhihui Tang; Yi Deng; Shicheng Wei
Journal:  PLoS One       Date:  2015-06-24       Impact factor: 3.240

5.  The possibility of recasting of pure titanium.

Authors:  Pei-Ling Lai; Wen-Cheng Chen; Jen-Chyan Wang; Po-Sung Fu; Chih-Chiang Lin; Chun-Cheng Hung
Journal:  J Dent Sci       Date:  2017-04-01       Impact factor: 2.080

6.  Demonstration of a SiC Protective Coating for Titanium Implants.

Authors:  Chaker Fares; Shu-Min Hsu; Minghan Xian; Xinyi Xia; Fan Ren; John J Mecholsky; Luiz Gonzaga; Josephine Esquivel-Upshaw
Journal:  Materials (Basel)       Date:  2020-07-26       Impact factor: 3.623

7.  Effect of tightening torque on the marginal adaptation of cement-retained implant-supported fixed dental prostheses.

Authors:  Jalil Ghanbarzadeh; Hossin Dashti; Reza Karamad; Marzieh Alikhasi; Mohammadreza Nakhaei
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug

8.  The effect of fluoride-containing oral rinses on the corrosion resistance of titanium alloy (Ti-6Al-4V).

Authors:  Gui-Yue Huang; Heng Bo Jiang; Jung-Yul Cha; Kwang-Mahn Kim; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2017-07-27       Impact factor: 1.372

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.