Literature DB >> 15599667

Efficient foldover suppression using SENSE.

R Winkelmann1, P Börnert, K Nehrke, O Dössel.   

Abstract

Parallel imaging techniques, which in principle represent procedures of unfolding a reduced dataset, are well known and well established in MR imaging. This paper presents a further application of one particular reconstruction method, the SENSE algorithm, considered from a different point of view to remove potential foldover in conventional images acquired with multiple receive coils. Based on the coil sensitivity information, a body coverage map in the excited plane is calculated. This is used together with the measured raw data in a SENSE-type reconstruction to optimize the signal-to-noise ratio (SNR) as well as to remove foldover reliably by unfolding the image to a larger field of view. The reconstruction is performed automatically, without any user interaction, and does not affect data acquisition. Based on phantom and in vivo studies, which retain high image quality after the removal, the potential and limits of this approach are discussed, also taking into account future scanner hardware that will support a large number of parallel receiver channels.

Mesh:

Year:  2004        PMID: 15599667     DOI: 10.1007/s10334-004-0081-5

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  7 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  A generalized approach to parallel magnetic resonance imaging.

Authors:  D K Sodickson; C A McKenzie
Journal:  Med Phys       Date:  2001-08       Impact factor: 4.071

3.  Artifact suppression in imaging of myocardial infarction using B1-weighted phased-array combined phase-sensitive inversion recovery.

Authors:  Peter Kellman; Christopher K Dyke; Anthony H Aletras; Elliot R McVeigh; Andrew E Arai
Journal:  Magn Reson Med       Date:  2004-02       Impact factor: 4.668

4.  Parallel imaging reconstruction using automatic regularization.

Authors:  Fa-Hsuan Lin; Kenneth K Kwong; John W Belliveau; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2004-03       Impact factor: 4.668

5.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

6.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

7.  2D SENSE for faster 3D MRI.

Authors:  Markus Weiger; Klaas P Pruessmann; Peter Boesiger
Journal:  MAGMA       Date:  2002-03       Impact factor: 2.533

  7 in total
  5 in total

Review 1.  Parallel magnetic resonance imaging.

Authors:  Ulrich Katscher; Peter Börnert
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

2.  A method to correct background phase offset for phase-contrast MRI in the presence of steady flow and spatial wrap-around artifact.

Authors:  Aaron A Pruitt; Ning Jin; Yingmin Liu; Orlando P Simonetti; Rizwan Ahmad
Journal:  Magn Reson Med       Date:  2018-11-15       Impact factor: 4.668

3.  Novel retrospective, respiratory-gating method enables 3D, high resolution, dynamic imaging of the upper airway during tidal breathing.

Authors:  Mark E Wagshul; Sanghun Sin; Michael L Lipton; Keivan Shifteh; Raanan Arens
Journal:  Magn Reson Med       Date:  2013-02-07       Impact factor: 4.668

4.  Evaluation of optimized breath-hold and free-breathing 3D ultrashort echo time contrast agent-free MRI of the human lung.

Authors:  Neville D Gai; Ashkan Malayeri; Harsh Agarwal; Robert Evers; David Bluemke
Journal:  J Magn Reson Imaging       Date:  2015-10-13       Impact factor: 4.813

5.  In-vivo validation of interpolation-based phase offset correction in cardiovascular magnetic resonance flow quantification: a multi-vendor, multi-center study.

Authors:  Mark B M Hofman; Manouk J A Rodenburg; Karin Markenroth Bloch; Beat Werner; Jos J M Westenberg; Emanuela R Valsangiacomo Buechel; Robin Nijveldt; Onno A Spruijt; Philip J Kilner; Albert C van Rossum; Peter D Gatehouse
Journal:  J Cardiovasc Magn Reson       Date:  2019-05-20       Impact factor: 5.364

  5 in total