Lack of equivalence between central and mixed venous oxygen saturation.

Lakhmir S Chawla1, Hasan Zia, Guillermo Gutierrez, Nevin M Katz, Michael G Seneff, Muhammed Shah.   

Abstract

STUDY
OBJECTIVE: We compared paired samples of central venous O(2) saturation (Scvo(2)) and mixed venous O(2) saturation (Svo(2)) to test the hypothesis that Scvo(2) is equivalent to Svo(2). We also compared O(2) consumption (Vo(2)) computed with Scvo(2) (Vo(2)cv) to that computed with Svo(2) (Vo(2)v).
DESIGN: Prospective, sequential, observational study.
SETTING: Combined medical-surgical ICU. PATIENTS: Fifty-three individuals > 18 years of age of either sex who required a pulmonary artery catheter (PAC) to guide fluid therapy. Subjects were identified as postsurgical (32 patients) or medical (21 patients) according to their ICU admission diagnosis.
INTERVENTIONS: A PAC was inserted through the internal jugular or subclavian veins. Care was taken to place the PAC proximal port approximately 3 cm above the tricuspid valve. Blood samples were drawn from the proximal and distal ports in random order. An arterial blood sample also was drawn. MEASUREMENTS: Cardiac output in triplicate, systemic pressure, and central pressure. We analyzed blood samples for hemoglobin concentration and O(2) saturation (So(2)). Data were compared by correlation analysis and by the method of Bland and Altman.
RESULTS: Svo(2) was consistently lower than Scvo(2) (p < 0.0001), with a mean (+/-SD) bias of -5.2 +/- 5.1%. Similar differences in Scvo(2) and Svo(2) were present within each subgroup (p < 0.001). A lower Svo(2) resulted in Vo(2)v values that were higher than the Vo(2)cv values for all patients in the study (mean Vo(2)v, 236.7 +/- 103.4 mL/min; mean Vo(2)cv, 191.1 +/- 84.0 mL/min; p < 0.001) as well as for patients within each subgroup (p < 0.001).
CONCLUSIONS: Measurements of Scvo(2) and Svo(2) were not equivalent in this sample of critically ill patients. Moreover, substituting Scvo(2) for Svo(2) in the calculation of Vo(2) produced unacceptably large errors. The decrease in So(2) between Scvo(2) to Svo(2) may result from the mixing of atrial and coronary sinus blood. As such, this difference may be a marker of myocardial O(2) consumption.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15596689     DOI: 10.1378/chest.126.6.1891

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  37 in total

1.  Using physiological models and decision theory for selecting appropriate ventilator settings.

Authors:  S E Rees; C Allerød; D Murley; Y Zhao; B W Smith; S Kjaergaard; P Thorgaard; S Andreassen
Journal:  J Clin Monit Comput       Date:  2006-09-15       Impact factor: 2.502

2.  Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock.

Authors:  Marjut Varpula; Sari Karlsson; Esko Ruokonen; Ville Pettilä
Journal:  Intensive Care Med       Date:  2006-07-07       Impact factor: 17.440

Review 3.  [Haemodynamic monitoring in the perioperative phase. Available systems, practical application and clinical data].

Authors:  U Wittkowski; C Spies; M Sander; J Erb; A Feldheiser; C von Heymann
Journal:  Anaesthesist       Date:  2009-08       Impact factor: 1.041

4.  Evaluation of a computer program for non-invasive determination of pulmonary shunt and ventilation-perfusion mismatch.

Authors:  Geoffrey G Lockwood; Nick L S Fung; J Gareth Jones
Journal:  J Clin Monit Comput       Date:  2014-01-09       Impact factor: 2.502

Review 5.  [Volume replacement in intensive care medicine].

Authors:  B Nohé; A Ploppa; V Schmidt; K Unertl
Journal:  Anaesthesist       Date:  2011-05       Impact factor: 1.041

6.  Association of physical examination with pulmonary artery catheter parameters in acute lung injury.

Authors:  Colin K Grissom; Alan H Morris; Paul N Lanken; Marek Ancukiewicz; James F Orme; David A Schoenfeld; B Taylor Thompson
Journal:  Crit Care Med       Date:  2009-10       Impact factor: 7.598

7.  Central venous-arterial pCO₂ difference as a tool in resuscitation of septic patients.

Authors:  Paul A van Beest; Mariska C Lont; Nicole D Holman; Bert Loef; Michaël A Kuiper; E Christiaan Boerma
Journal:  Intensive Care Med       Date:  2013-04-05       Impact factor: 17.440

8.  Low and "supranormal" central venous oxygen saturation and markers of tissue hypoxia in cardiac surgery patients: a prospective observational study.

Authors:  Suzanne Perz; Thomas Uhlig; Matthias Kohl; Donald L Bredle; Konrad Reinhart; Michael Bauer; Andreas Kortgen
Journal:  Intensive Care Med       Date:  2010-08-06       Impact factor: 17.440

9.  The PICU perspective on monitoring hemodynamics and oxygen transport.

Authors:  Hector R Wong; Heidi J Dalton
Journal:  Pediatr Crit Care Med       Date:  2011-07       Impact factor: 3.624

10.  ACCM/PALS haemodynamic support guidelines for paediatric septic shock: an outcomes comparison with and without monitoring central venous oxygen saturation.

Authors:  Cláudio F de Oliveira; Débora S F de Oliveira; Adriana F C Gottschald; Juliana D G Moura; Graziela A Costa; Andréa C Ventura; José Carlos Fernandes; Flávio A C Vaz; Joseph A Carcillo; Emanuel P Rivers; Eduardo J Troster
Journal:  Intensive Care Med       Date:  2008-03-28       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.