The influence of tissue depth and composition on the performance of the Lunar dual-energy X-ray absorptiometer whole-body scanning mode.

M A Laskey1, K D Lyttle, M E Flaxman, R W Barber.   

Abstract

To assess the performance of the Lunar dual-energy X-ray absorptiometer (DPX) whole-body scanning mode (software version 3.1), a simple phantom was devised. This had known but variable amounts of lard to represent fat, and water to represent fat-free tissue. The bone mineral content of the phantom remained constant and consisted of the Lunar spine phantom to represent the spine/trunk and a slab of aluminium to represent the head. This phantom was scanned using the whole-body mode by the Lunar DPX to determine bone mineral content (BMC), area, bone mineral density (BMD), and body composition in terms of fat and fat-free tissue. The determinations of total tissue mass were very accurate and precise but fat tissue mass was slightly overestimated (103% of calculated value) and lean tissue mass slightly underestimated (98% of calculated value). The spine and head sections of the phantom were scanned individually using the spine mode and hence by addition the total BMC, area, and BMD of the whole phantom were determined. These results were compared to the bone mineral results obtained using the whole-body mode. The whole-body mode gave higher values for BMC and area than spine-mode measurements (at depths above 10 cm). This discrepancy increased with increasing depths of water (140% and 170% respectively of spine-mode value at soft-tissue depths of 22 cm and 15% fat). The values for BMD of the whole phantom tended to decrease with increasing depths of water and were lower than spine-mode values at tissue depths above 12cm.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1559506

Source DB:  PubMed          Journal:  Eur J Clin Nutr        ISSN: 0954-3007            Impact factor:   4.016


  14 in total

1.  Dual-energy X-ray absorptiometry underestimates in vivo lumbar spine bone mineral density in overweight rats.

Authors:  Rim Cherif; Laurence Vico; Norbert Laroche; Mohsen Sakly; Nebil Attia; Cedric Lavet
Journal:  J Bone Miner Metab       Date:  2017-02-01       Impact factor: 2.626

Review 2.  The assessment of body composition in patients with cirrhosis.

Authors:  M Y Morgan; A M Madden
Journal:  Eur J Nucl Med       Date:  1996-02

3.  Bone strength is preserved following bariatric surgery.

Authors:  Lesley M Scibora; Henry Buchwald; Moira A Petit; Julie Hughes; Sayeed Ikramuddin
Journal:  Obes Surg       Date:  2015-02       Impact factor: 4.129

4.  Phantom studies in osteoporosis.

Authors:  M Fischer; B Kempers
Journal:  Eur J Nucl Med       Date:  1993-05

5.  Reproducibility and accuracy of body composition assessments in mice by dual energy x-ray absorptiometry and time domain nuclear magnetic resonance.

Authors:  Solveig Halldorsdottir; Jill Carmody; Carol N Boozer; Charles A Leduc; Rudolph L Leibel
Journal:  Int J Body Compos Res       Date:  2009

6.  Validation of fan beam dual energy x ray absorptiometry for body composition assessment in adults aged 18-45 years.

Authors:  J Norcross; M D Van Loan
Journal:  Br J Sports Med       Date:  2004-08       Impact factor: 13.800

7.  Evaluation of between-methods agreement of extracellular water measurements in adults and children.

Authors:  Analiza M Silva; Steven B Heymsfield; Dympna Gallagher; Jeanine Albu; Xavier F Pi-Sunyer; Richard N Pierson; Jack Wang; Stanley Heshka; Luis B Sardinha; Zimian Wang
Journal:  Am J Clin Nutr       Date:  2008-08       Impact factor: 7.045

8.  Measurement of percentage of body fat in 411 children and adolescents: a comparison of dual-energy X-ray absorptiometry with a four-compartment model.

Authors:  Aviva B Sopher; John C Thornton; Jack Wang; Richard N Pierson; Steven B Heymsfield; Mary Horlick
Journal:  Pediatrics       Date:  2004-05       Impact factor: 7.124

9.  Premenopausal overweight women do not lose bone during moderate weight loss with adequate or higher calcium intake.

Authors:  Claudia S Riedt; Yvette Schlussel; Nancy von Thun; Hasina Ambia-Sobhan; Theodore Stahl; M Paul Field; Robert M Sherrell; Sue A Shapses
Journal:  Am J Clin Nutr       Date:  2007-04       Impact factor: 7.045

Review 10.  Pediatric body composition analysis with dual-energy X-ray absorptiometry.

Authors:  Maura Helba; Larry A Binkovitz
Journal:  Pediatr Radiol       Date:  2009-05-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.