Performance improvement of small gamma camera using NaI(Tl) plate and position sensitive photo-multiplier tubes.

Myung Hwan Jeong1, Yong Choi, Yong Hyun Chung, Tae Yong Song, Jin Ho Jung, Key Jo Hong, Byung Jun Min, Yearn Seong Choe, Kyung-Han Lee, Byung-Tae Kim.   

Abstract

The purpose of this study was to improve the performance of a small gamma camera, utilizing a NaI(Tl) plate and a 5" position sensitive PMT. We attempted to build a NaI(Tl) plate crystal system which retained all its advantages, while at the same time integrating some of the advantages inherent in an array-type scintillation crystal system. Flood images were obtained with a lead hole mask, and position mapping was performed by detecting hole positions in the flood image. Energy calibration was performed using the energy spectra obtained from each hole position. Flood correction was performed using a uniformity correction table containing the relative efficiency of each image element. The spatial resolution was improved about 16% after correction at the centre field of view. Resolution deterioration at the outer field of view (OFOV) was considerably ameliorated, from 6.7 mm to 3.2 mm after correction. The sensitivity at the OFOV was also increased after correction, from 0.7 cps microCi(-1) to 2.0 cps microCi(-1). The correction also improved uniformity, from 5.2% to 2.1%, and linearity, from 0.5 mm to 0 mm. The results of this study indicate that the revised correction method can be employed to considerably improve the performance of a small gamma camera using a NaI(Tl) plate-type crystal. This method also provides high spatial resolution and linearity, like array-type crystals do, while retaining the specific advantages of plate-type crystals.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15584530     DOI: 10.1088/0031-9155/49/21/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  Characterization of "γ-Eye": a Low-Cost Benchtop Mouse-Sized Gamma Camera for Dynamic and Static Imaging Studies.

Authors:  Maria Georgiou; Eleftherios Fysikopoulos; Konstantinos Mikropoulos; Eirini Fragogeorgi; George Loudos
Journal:  Mol Imaging Biol       Date:  2017-06       Impact factor: 3.488

2.  A high-sensitivity small animal SPECT system.

Authors:  Gregory S Mitchell; Simon R Cherry
Journal:  Phys Med Biol       Date:  2009-02-03       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.