Literature DB >> 15583919

The safety and efficacy of a powered toothbrush on soft tissues in patients with implant-supported fixed prostheses.

B Vandekerckhove1, M Quirynen, P R Warren, J Strate, D van Steenberghe.   

Abstract

The safety, efficacy and acceptability of an oscillating/rotating powered toothbrush was assessed in patients rehabilitated with fixed prostheses on implants. One hundred consecutive patients (aged 18-80; mean 56.3; 51 females), who met the inclusion/exclusion criteria and who participated in a regular annual recall scheme, were enrolled. They were instructed on how to use the powered toothbrush, as well as on classical interdental plaque control. The electric toothbrush had to be used twice daily for 2 min. The following periodontal parameters were measured at baseline and at 3 months, 6 months and 12 months: presence/absence of gingival and/or mucosal ulceration/desquamation; sulcus bleeding index; probing pocket depth; periodontal pocket-bleeding index and gingival recession. At 3 months and at the end of the study, patients completed a questionnaire concerning the overall acceptability and convenience of the powered toothbrush, as compared with their habitual manual toothbrush. A total of 80 patients completed the study. No dropouts were related to the use of the powered toothbrush. All parameters improved over the course of the study. The mean overall pocket depth decreased from 3.3 mm at baseline to 3.0 mm at 12 months, while the mean decrease in recession was 0.1 mm at 12 months. During the 1-year observation, there was a slight gain in periodontal attachment level. Gingival ulcerations were not observed at any point in the study. High scores for convenience and comfort of the powered toothbrush were reported, and the majority (95%) said that they would continue to use it for habitual oral hygiene. It is concluded that the powered toothbrush investigated is effective, safe and comfortable for patients rehabilitated by means of oral implant-supported prostheses.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15583919     DOI: 10.1007/s00784-004-0278-z

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  22 in total

1.  The efficacy of a counter-rotational powered toothbrush in the maintenance of endosseous dental implants.

Authors:  R S Truhlar; H F Morris; S Ochi
Journal:  J Am Dent Assoc       Date:  2000-01       Impact factor: 3.634

2.  Relative effectiveness of powered and manual toothbrushes in elderly patients with implant-supported mandibular overdentures.

Authors:  A Tawse-Smith; W J Duncan; A G T Payne; W M Thomson; J L Wennström
Journal:  J Clin Periodontol       Date:  2002-04       Impact factor: 8.728

Review 3.  Treatment of peri-implant infections: a literature review.

Authors:  Ann-Marie Roos-Jansåker; Stefan Renvert; Jan Egelberg
Journal:  J Clin Periodontol       Date:  2003-06       Impact factor: 8.728

4.  Probing force and the relationship of the probe tip to the periodontal tissues.

Authors:  U van der Velden
Journal:  J Clin Periodontol       Date:  1979-04       Impact factor: 8.728

Review 5.  Infectious risks for oral implants: a review of the literature.

Authors:  Marc Quirynen; Marc De Soete; Daniel van Steenberghe
Journal:  Clin Oral Implants Res       Date:  2002-02       Impact factor: 5.977

6.  The influence of the masticatory mucosa on the peri-implant soft tissue condition.

Authors:  J L Wennström; F Bengazi; U Lekholm
Journal:  Clin Oral Implants Res       Date:  1994-03       Impact factor: 5.977

7.  A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants. Clinical results and marginal bone loss.

Authors:  L W Lindquist; G E Carlsson; T Jemt
Journal:  Clin Oral Implants Res       Date:  1996-12       Impact factor: 5.977

Review 8.  The role of the electric toothbrush in the control of plaque and gingivitis: a review of 5 years clinical experience with the Braun Oral-B Plaque Remover [D7].

Authors:  P R Warren; B Chater
Journal:  Am J Dent       Date:  1996-07       Impact factor: 1.522

9.  Effectiveness of a sonic toothbrush in maintenance of dental implants. A prospective study.

Authors:  L Wolff; A Kim; M Nunn; B Bakdash; J Hinrichs
Journal:  J Clin Periodontol       Date:  1998-10       Impact factor: 8.728

10.  The condition of the soft tissues at tooth and fixture abutments supporting fixed bridges. A microbiological and histological study.

Authors:  U Lekholm; I Ericsson; R Adell; J Slots
Journal:  J Clin Periodontol       Date:  1986-07       Impact factor: 8.728

View more
  2 in total

1.  Efficacy of sonic-powered toothbrushes for plaque removal in patients with peri-implant mucositis.

Authors:  Jungwon Lee; Jong Heun Lim; Jungeun Lee; Sungtae Kim; Ki-Tae Koo; Yang-Jo Seol; Young Ku; Yong-Moo Lee; In-Chul Rhyu
Journal:  J Periodontal Implant Sci       Date:  2015-04-29       Impact factor: 2.614

2.  An 8-week randomized controlled trial comparing the effect of a novel oscillating-rotating toothbrush versus a manual toothbrush on plaque and gingivitis.

Authors:  Julie Grender; C Ram Goyal; Jimmy Qaqish; Ralf Adam
Journal:  Int Dent J       Date:  2020-04       Impact factor: 2.607

  2 in total