Literature DB >> 10649881

The efficacy of a counter-rotational powered toothbrush in the maintenance of endosseous dental implants.

R S Truhlar1, H F Morris, S Ochi.   

Abstract

BACKGROUND: Although most patients with implants have lost their natural teeth because of poor oral hygiene, limited data exist to guide practitioners in their recommendations of home-care regimens for their patients' endosseous dental implants and maintenance of peri-implant soft-tissue health. The authors conducted a study to compare the home-care effectiveness of a counter-rotational powered tooth-brush with that of conventional home-care regimens.
METHODS: Before starting the six-year study, the authors trained 85 clinical investigators at 32 dental research centers across the United States in gathering periodontal data. Data for 2,966 implants were entered into a centralized database. Outcomes were derived from 24-month observations of a subset of the implants studied.
RESULTS: Repeated-measures analysis of the toothbrushing methods used on 2,966 implants showed that the counter-rotational powered toothbrush removed plaque significantly better than manual methods (P < .0001 Wald statistic) from all implant surfaces and at all recall intervals up to 24 months. Similar results were demonstrated for the gingival index.
CONCLUSIONS: The counter-rotational powered brush appears to be well-suited for home-care regimens aimed at maintaining optimal peri-implant soft-tissue health in patients with dental implants. CLINICAL IMPLICATIONS: The importance of maintaining the health of the peri-implant tissues is well-recognized by the dental profession. The counter-rotational powered toothbrush is an effective tool in meeting the oral hygiene challenges associated with implant prosthesis maintenance.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10649881     DOI: 10.14219/jada.archive.2000.0028

Source DB:  PubMed          Journal:  J Am Dent Assoc        ISSN: 0002-8177            Impact factor:   3.634


  3 in total

Review 1.  Interventions for replacing missing teeth: maintaining and recovering soft tissue health around dental implants.

Authors:  Maria Gabriella Grusovin; Paul Coulthard; Helen V Worthington; Peter George; Marco Esposito
Journal:  Cochrane Database Syst Rev       Date:  2010-08-04

2.  The safety and efficacy of a powered toothbrush on soft tissues in patients with implant-supported fixed prostheses.

Authors:  B Vandekerckhove; M Quirynen; P R Warren; J Strate; D van Steenberghe
Journal:  Clin Oral Investig       Date:  2004-07-28       Impact factor: 3.573

Review 3.  Safety and Design Aspects of Powered Toothbrush-A Narrative Review.

Authors:  Clarence Ng; James Kit Hon Tsoi; Edward C M Lo; And Jukka P Matinlinna
Journal:  Dent J (Basel)       Date:  2020-02-05
  3 in total