Literature DB >> 15582229

Simulation study of effects of speed of sound and attenuation on ultrasound lateral resolution.

Quan Chen1, James A Zagzebski.   

Abstract

Experiments have shown that the lateral profile of a point target measured with a clinical ultrasound scanner is wider when the target is embedded in a urethane phantom than when it is in a traditional gel phantom. The behavior has been attributed to the low speed of sound in the urethane material, with the possibility that some of the broadening is caused by increased attenuation in this material. In this paper we apply a computer simulation model to study this behavior. Lateral beam profiles modeled for targets within a medium having a speed of sound and an attenuation matching that of urethane are compared with profiles for targets in a water-based gel. Simulations yield results that agree qualitatively with published experimental results. The lateral profile broadening in urethane is caused by the 6 % mismatch between speed of sound in this material and the speed of sound assumed in the receive focusing and beam forming. Attenuation plays a lesser role than the mismatch of the speed of sound.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15582229     DOI: 10.1016/j.ultrasmedbio.2004.07.012

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

1.  Average sound speed estimation using speckle analysis of medical ultrasound data.

Authors:  Xiaolei Qu; Takashi Azuma; Jack T Liang; Yoshikazu Nakajima
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-04-28       Impact factor: 2.924

2.  Quality control of ultrasound transducers: analysis of evaluation parameters and results of a survey of 116 transducers in a single hospital.

Authors:  P Cozzolino; R Stramare; A Udilano; M Castoro; E Scagliori; V Beltrame; L Rubaltelli
Journal:  Radiol Med       Date:  2010-02-22       Impact factor: 3.469

3.  Stolt's f-k migration for plane wave ultrasound imaging.

Authors:  Damien Garcia; Louis Le Tarnec; Stéphan Muth; Emmanuel Montagnon; Jonathan Porée; Guy Cloutier
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

4.  Early experience with automated B-mode quality assurance tests.

Authors:  N J Dudley; N M Gibson
Journal:  Ultrasound       Date:  2013-12-19

5.  Ultrasound attenuation measurements using a reference phantom with sound speed mismatch.

Authors:  Kibo Nam; Ivan M Rosado-Mendez; Nicholas C Rubert; Ernest L Madsen; James A Zagzebski; Timothy J Hall
Journal:  Ultrason Imaging       Date:  2011-10       Impact factor: 1.578

6.  Testing a dual-modality system that combines full-field digital mammography and automated breast ultrasound.

Authors:  Christopher L Vaughan; Tania S Douglas; Qonita Said-Hartley; Roland V Baasch; James A Boonzaier; Brian C Goemans; John Harverson; Michael W Mingay; Shuaib Omar; Raphael V Smith; Nielen C Venter; Heidi S Wilson
Journal:  Clin Imaging       Date:  2015-12-03       Impact factor: 1.605

  6 in total