Literature DB >> 15581766

Salvage revision total knee replacement using the Endo-Model rotating hinge prosthesis.

N R Pradhan1, L Bale, P Kay, M L Porter.   

Abstract

Inability to balance a knee in complex revision total knee replacement has led to the use of rotating hinged knee devices in these cases as a salvage procedure. We conducted a retrospective study of 50 patients receiving 51 Endo-Model rotating hinge prosthesis with an average follow-up of 4 years (range 2-6 years). Clinical and radiological results were reviewed at latest follow-up. Five patients died from unrelated causes. Reasons for revision were infection (23), aseptic loosening (23), implant failure (3), stiffness (1) and peri-prosthetic fracture (1). The average number of previous surgery from and including the primary arthroplasty was three (ranges 1-14). Seven patients required plastic surgery for soft tissue cover. There was notable improvement in the pain, stability, range of motion and mobility of the patients with an improvement in the Hospital for Special Surgery Score (35.9 to 72.17). Postoperatively, 11 (22%) had an excellent HSS grade, 22 (44%) good grade, 10 (19%) fair grade and 8 (15%) poor grade. A significant number of our patients had an extremely low preoperative HSS score, and for these patients, an improvement to a fair grade HSS score was a satisfactory and realistic outcome. Forty-four (86%) patients were satisfied with the outcome of the revision surgery, 3 (6%) noncommittal and 4 (8%) disappointed. Comparing revision for infection vs. aseptic loosening, 22 (95%) patients out of 23 were satisfied in the aseptic loosening group vs. 17 (74%) out of 23 were satisfied in the infected group. In selected complex cases, salvage revision surgery shows encouraging results in the short to medium term using the Endo-Model rotating hinge prosthesis. A knee score such as the Hospital for Special Surgery score (objective outcome) should be used in conjunction with a patient satisfaction questionnaire (subjective outcome) in assessing the clinical outcome of complex, salvage revision knee surgery. Revision for infected total knee replacement is less likely to produce a satisfactory outcome as compared to revision for aseptic loosening.

Entities:  

Mesh:

Year:  2004        PMID: 15581766     DOI: 10.1016/j.knee.2004.03.001

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  23 in total

Review 1.  [Periprosthetic knee infection. One-stage exchange].

Authors:  C Friesecke; J Wodtke
Journal:  Orthopade       Date:  2006-09       Impact factor: 1.087

2.  Case report: Failure of rotating-hinge total knee prosthesis by disengagement of the hinge-post extension.

Authors:  Debdut Biswas; Bryan Haughom; Robert E Mayle; Craig J Della Valle
Journal:  Clin Orthop Relat Res       Date:  2012-12-11       Impact factor: 4.176

3.  Cementless revision TKA with bone grafting of osseous defects restores bone stock with a low revision rate at 4 to 10 years.

Authors:  S A Hanna; W J S Aston; N J de Roeck; A Gough-Palmer; D P Powles
Journal:  Clin Orthop Relat Res       Date:  2011-06-16       Impact factor: 4.176

4.  [The modular MML revision system in knee revision and tumor arthroplasty].

Authors:  L Gerdesmeyer; A Töpfer; J Kircher; H Grundei; P Diehl
Journal:  Orthopade       Date:  2006-09       Impact factor: 1.087

5.  Revision knee arthroplasty with rotating hinge systems in patients with gross ligament instability.

Authors:  Sebastian P Boelch; Joerg Arnholdt; Boris M Holzapfel; Axel Jakuscheit; Maximilian Rudert; Maik Hoberg
Journal:  Int Orthop       Date:  2018-05-22       Impact factor: 3.075

6.  Hinged total knee arthroplasty in the presence of ligamentous deficiency.

Authors:  Daniel Hernández-Vaquero; Manuel A Sandoval-García
Journal:  Clin Orthop Relat Res       Date:  2010-05       Impact factor: 4.176

7.  KNEE ARTHROPLASTY REVISION WITH A CONSTRAINED IMPLANT USING HINGE AND ROTATING TIBIAL BASIS.

Authors:  Fabio Jansen Angelini; Camilo Partezani Helito; Bruno Azevedo Veronesi; Tales Mollica Guimarães; José Ricardo Pécora; Marco Kawamura Demange
Journal:  Acta Ortop Bras       Date:  2016 Jan-Feb       Impact factor: 0.513

8.  Distal femoral replacement in nontumor cases with severe bone loss and instability.

Authors:  Keith R Berend; Adolph V Lombardi
Journal:  Clin Orthop Relat Res       Date:  2008-06-04       Impact factor: 4.176

9.  The Endo-Model(®) rotating hinge for rheumatoid knees : Functional results in primary and revision surgery.

Authors:  L Felli; M Coviello; M Alessio-Mazzola; M Cutolo
Journal:  Orthopade       Date:  2016-05       Impact factor: 1.087

10.  Revision knee arthroplasty with a rotating-hinge design in elderly patients with instability following total knee arthroplasty.

Authors:  E Carlos Rodríguez-Merchán; Primitivo Gómez-Cardero; Ángel Martínez-Lloreda
Journal:  J Clin Orthop Trauma       Date:  2014-11-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.