Literature DB >> 15580442

Prevention of lens condensation in laparoscopic surgery by lens heating with a thermos flask.

D F P Van Deurzen, G H H Mannaerts, J J Jakimowicz, A Cuschieri.   

Abstract

Condensation on the scope lens as a result of differences between room and intraabdominal temperatures is a disturbing problem for laparoscopic surgeons. Despite the use of anti-lens condensation solutions, this cannot be entirely avoided. The authors report a simple, cheap, and effective method for preventing lens condensation by lens heating using a sterilized thermos flask filled with hot water.

Mesh:

Substances:

Year:  2004        PMID: 15580442     DOI: 10.1007/s00464-004-8231-4

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  1 in total

1.  Laparoscopic hypothermia: heat loss from insufflation gas flow.

Authors:  T R Huntington; C B LeMaster
Journal:  Surg Laparosc Endosc       Date:  1997-04
  1 in total
  10 in total

1.  Easy cleaning of the scope's lens in a syringe to prevent condensation during laparoscopic surgery.

Authors:  A J Runia; J F Zengerink; G H H Mannaerts
Journal:  Surg Endosc       Date:  2009-08-26       Impact factor: 4.584

2.  Technical means to improve image quality during thoracoscopic procedures.

Authors:  Dominique Gossot; Madalina Grigoroiu; Emmanuel Brian; Agathe Seguin-Givelet
Journal:  J Vis Surg       Date:  2017-04-10

3.  Laparoscopic lens fogging: solving a common surgical problem in standard and robotic laparoscopes via a scientific model.

Authors:  Todd G Manning; Nathan Papa; Marlon Perera; Shannon McGrath; Daniel Christidis; Munad Khan; Richard O'Beirne; Nicholas Campbell; Damien Bolton; Nathan Lawrentschuk
Journal:  Surg Endosc       Date:  2017-08-08       Impact factor: 4.584

4.  Prospective, randomized comparison of the use of FloShield Air System® versus the reference technique (water + povidone-iodine solution) during gynecologic endoscopic surgery to evaluate the operative lens vision quality.

Authors:  S Bendifallah; E Salakos; I Naoura; P Aristizabal; E Furet; S Zilberman; M Ballester; E Darai
Journal:  Surg Endosc       Date:  2017-06-22       Impact factor: 4.584

5.  Elimination of laparoscopic lens fogging using directional flow of CO2.

Authors:  John Teague Calhoun; Jay A Redan
Journal:  JSLS       Date:  2014 Jan-Mar       Impact factor: 2.172

6.  A novel device for cleaning the camera port during laparoscopic surgery.

Authors:  Eiji Kobayashi; Mamoru Kakuda; Yusuke Tanaka; Akiko Morimoto; Tomomi Egawa-Takata; Shinya Matsuzaki; Toshihiro Kimura; Yutaka Ueda; Kiyoshi Yoshino; Kiyokazu Nakajima; Tadashi Kimura
Journal:  Surg Endosc       Date:  2015-06-20       Impact factor: 4.584

7.  A novel one-step lens cleaning device using air and water flow for endoscopic surgery.

Authors:  Hironori Tatsuki; Takehiko Yokobori; Chika Katayama; Ryuji Kato; Ryo Takahashi; Katsuya Osone; Takahiro Takada; Reina Yajima; Yoko Motegi; Hiroomi Ogawa; Takaaki Fujii; Ken Shirabe; Hiroyuki Kuwano; Takayuki Asao
Journal:  PLoS One       Date:  2018-07-18       Impact factor: 3.240

8.  A novel lens cleaner to prevent water drop adhesions during colonoscopy and esophagogastroduodenoscopy.

Authors:  Naohisa Yoshida; Yuji Naito; Ritsu Yasuda; Takaaki Murakami; Kiyoshi Ogiso; Ryohei Hirose; Yutaka Inada; Osamu Dohi; Tetsuya Okayama; Kazuhiro Kamada; Kazuhiko Uchiyama; Takeshi Ishikawa; Osamu Handa; Hideyuki Konishi; Rafiz Abdul Rani; Yoshito Itoh
Journal:  Endosc Int Open       Date:  2017-12-06

Review 9.  Review of Techniques to Achieve Optical Surface Cleanliness and Their Potential Application to Surgical Endoscopes.

Authors:  Davey Kreeft; Ewout Aart Arkenbout; Paulus Wilhelmus Johannes Henselmans; Wouter R van Furth; Paul Breedveld
Journal:  Surg Innov       Date:  2017-05-16       Impact factor: 2.058

Review 10.  Safety considerations in laparoscopic surgery: A narrative review.

Authors:  Brij Madhok; Kushan Nanayakkara; Kamal Mahawar
Journal:  World J Gastrointest Endosc       Date:  2022-01-16
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.