Results of reoperation for hip dislocation: the big picture.

Bernard F Morrey1.   

Abstract

Hip instability remains a costly complication of primary (3%) and revision (10%) procedures. In those with well-oriented components, instability may be anticipated in about 70% from advancement of the trochanter. Articular reorientation readily is affected by the use of modular cups with elevated rims. This has proven to be an effective strategy both to lessen the likelihood of an initial dislocation after both primary and revision procedures. It has also proven to be an effective strategy to treat the unstable implant, especially if cup orientation has been defined as the primary problem. Larger head sizes in the range of low-friction arthroplasty, such as 32 mm, are not any more stable than 22-mm diameter implants. Anatomic-sized heads as used in bipolar devices are effective in treating established instability in up to 90% of instances. The most popular current option is that of the constrained head/cup articulation. Good short-term results have revealed success in more than 90%. However, the effectiveness is design dependent, and the long-term effectiveness understandably is questioned as reports of mechanical failure begin to emerge.

Entities:  

Mesh:

Year:  2004        PMID: 15577472     DOI: 10.1097/01.blo.0000150318.27723.8c

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  6 in total

1.  Use of a dual mobility socket to manage total hip arthroplasty instability.

Authors:  Olivier Guyen; Vincent Pibarot; Gualter Vaz; Christophe Chevillotte; Jacques Béjui-Hugues
Journal:  Clin Orthop Relat Res       Date:  2008-09-09       Impact factor: 4.176

2.  Dual mobility cups provide biomechanical advantages in situations at risk for dislocation: a finite element analysis.

Authors:  Alexandre Terrier; Adeliya Latypova; Maika Guillemin; Valérie Parvex; Olivier Guyen
Journal:  Int Orthop       Date:  2017-01-09       Impact factor: 3.075

Review 3.  Total hip arthroplasty instability in Italy.

Authors:  Francesco Falez; Matteo Papalia; Fabio Favetti; Gabriele Panegrossi; Filippo Casella; Gianluca Mazzotta
Journal:  Int Orthop       Date:  2016-12-20       Impact factor: 3.075

4.  Quality of life following proximal femoral replacement using a modular system in revision THA.

Authors:  Muhyeddine M Al-Taki; Bassam A Masri; Clive P Duncan; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

5.  The use of a dual mobility cup in the management of recurrent dislocations of hip hemiarthroplasty.

Authors:  Christian Carulli; Armando Macera; Fabrizio Matassi; Roberto Civinini; Massimo Innocenti
Journal:  J Orthop Traumatol       Date:  2015-07-18

6.  Novel Constrained Dual Mobility Hip Prosthesis to Combat Instability in Revision Total Hip Arthroplasty whilst Preserving Normal Function.

Authors:  Michael Jiang; Anton Lambers; Rodney Richardson
Journal:  Case Rep Orthop       Date:  2020-07-07