Literature DB >> 15577468

Fatigue crack propagation resistance of highly crosslinked polyethylene.

Letitia Bradford1, David Baker, Michael D Ries, Lisa A Pruitt.   

Abstract

A higher degree of cross-linking has been shown to improve wear properties of ultra-high molecular weight polyethylene in laboratory studies. However, cross-linking can also affect the mechanical properties of ultra-high molecular weight polyethylene. Fatigue crack propagation resistance was determined for electron beam cross-linked ultra-high molecular weight polyethylene and compared with gamma irradiation cross-linked and noncross-linked polyethylene fatigue specimens. Crosslinking was done with different dosages of irradiation followed by melting. For one irradiation dose (50 kGy) extrusion and molding processes were compared. A fracture mechanics approach was used to determine how the degree of cross-linking affects resistance to crack propagation in ultra-high molecular weight polyethylene. Fatigue crack propagation resistance was reduced in proportion to the irradiation dose. The type of irradiation (gamma or electron beam) or manufacturing method (extrusion or molding) did not affect fatigue crack propagation resistance. The reduced fatigue strength of highly cross-linked ultra-high molecular weight polyethylene could lead to mechanical failure in conditions that are associated with cyclic local tensile stresses.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15577468     DOI: 10.1097/01.blo.0000150124.34906.34

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  22 in total

1.  Implant design influences tibial post wear damage in posterior-stabilized knees.

Authors:  Mark M Dolan; Natalie H Kelly; Joseph T Nguyen; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

2.  Head material influences survival of a cemented total hip prosthesis in the Norwegian Arthroplasty Register.

Authors:  Thomas Kadar; Eva Dybvik; Geir Hallan; Ove Furnes; Leif Ivar Havelin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

3.  Wear is reduced in THA performed with highly cross-linked polyethylene.

Authors:  Burak Beksaç; Antonio Salas; Alejandro González Della Valle; Eduardo A Salvati
Journal:  Clin Orthop Relat Res       Date:  2008-12-12       Impact factor: 4.176

4.  Early failure of a cross-linked polyethylene acetabular liner. A case report.

Authors:  K David Moore; Preston R Beck; Donald W Petersen; John M Cuckler; Jack E Lemons; Alan W Eberhardt
Journal:  J Bone Joint Surg Am       Date:  2008-11       Impact factor: 5.284

5.  Highly crosslinked polyethylene is safe for use in total knee arthroplasty.

Authors:  Jeffrey T Hodrick; Erik P Severson; Deborah S McAlister; Brian Dahl; Aaron A Hofmann
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

6.  Is there a difference in total knee arthroplasty risk of revision in highly crosslinked versus conventional polyethylene?

Authors:  Elizabeth W Paxton; Maria C S Inacio; Steven Kurtz; Rebecca Love; Guy Cafri; Robert S Namba
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

7.  Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes.

Authors:  Carmen Zietz; Christian Fabry; Lars Middelborg; Gerhard Fulda; Wolfram Mittelmeier; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2013-04-25       Impact factor: 3.896

8.  Highly crosslinked polyethylene improves wear but not surface damage in retrieved acetabular liners.

Authors:  Hee-Nee Pang; Douglas D R Naudie; Richard W McCalden; Steven J MacDonald; Matthew G Teeter
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

9.  Impingement in Total Hip Replacement: Mechanisms and Consequences.

Authors:  Thomas D Brown; John J Callaghan
Journal:  Curr Orthop       Date:  2008-12-01

Review 10.  Highly cross-linked polyethylene may not have an advantage in total knee arthroplasty.

Authors:  Vasileios I Sakellariou; Peter Sculco; Lazaros Poultsides; Timothy Wright; Thomas P Sculco
Journal:  HSS J       Date:  2013-08-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.