Literature DB >> 15561034

Flow in coronary bypass conduits on-pump and off-pump.

Henrik K Kjaergard1, Akhmad Irmukhamedov, John B Christensen, Thomas A Schmidt.   

Abstract

BACKGROUND: The purpose of the study was to measure the blood flow in coronary artery bypass grafting conduits on-pump and off-pump and to estimate the total conduit flow.
METHODS: In a 3.5-year period, 120 patients having coronary artery bypass grafting on-pump and 97 patients having coronary artery bypass grafting off-pump with the left internal mammary artery anastomosed to the left anterior descending artery and saphenous vein grafts to the remaining diseased coronary arteries were included in the study. Flow in the bypass conduits was measured with the transit-time method.
RESULTS: In men the left internal mammary artery flow (mean +/- standard error of the mean) was 33.7 +/- 2.0 mL/min on-pump and 34.4 +/- 2.9 off-pump (p > 0.05). In women the left internal mammary artery flow was 29.4 +/- 3.0 mL/min on-pump and 22.8 +/- 1.9 mL/min off-pump (p > 0.05). In men the vein graft flow per anastomosis was 30.4 +/- 1.3 mL/min on-pump and 37.8 +/- 5.4 mL/min off-pump (p > 0.05). In women the vein graft flow per anastomosis was 28.0 +/- 2.9 mL/min on-pump and 23.2 +/- 2.9 mL/min off-pump (p > 0.05). Consistently in women, the mean conduit flows were numerically lower than in men. In patients undergoing coronary artery bypass grafting on-pump the total conduit flows (left internal mammary artery plus vein grafts) were 131.4 +/- 2.5 mL/min in men and 108.4 +/- 3.2 mL/min in women.
CONCLUSIONS: There were no major differences in conduit flow on-pump versus off-pump. Conventional coronary artery bypass grafting on-pump may restore up to approximately half of the normal resting coronary artery blood flow (250 mL/min).

Entities:  

Mesh:

Year:  2004        PMID: 15561034     DOI: 10.1016/j.athoracsur.2004.06.009

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  5 in total

1.  Intraoperative assessment and quantification of coronary artery graft patency performed on or off cardiopulmonary bypass.

Authors:  Eric D Rauch; Christopher Leach; Terry Barnes; Kurt Driscoll; Kurt Strutz; David W Holt
Journal:  J Extra Corpor Technol       Date:  2007-06

2.  The application of intraoperative transit time flow measurement to accurately assess anastomotic quality in sequential vein grafting.

Authors:  Yang Yu; Fan Zhang; Ming-Xin Gao; Hai-Tao Li; Jing-Xing Li; Wei Song; Xin-Sheng Huang; Cheng-Xiong Gu
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-09-01

3.  Contrast-enhanced cardiac MRI before coronary artery bypass surgery: impact of myocardial scar extent on bypass flow.

Authors:  Peter Hunold; Parwis Massoudy; Claudia Boehm; Thomas Schlosser; Kai Nassenstein; Stephan Knipp; Holger Eggebrecht; Matthias Thielmann; Raimund Erbel; Heinz Jakob; Jörg Barkhausen
Journal:  Eur Radiol       Date:  2008-06-26       Impact factor: 5.315

4.  Association of Internal Mammary Artery Flow with Different Comorbidities and Post-Coronary Artery Bypass Graft Complications.

Authors:  Mudassir Iqbal Dar; Asim Hassan Dar; Muhammad Bilal; Mansoor Ahmad; Abdul Haseeb
Journal:  Cureus       Date:  2017-08-20

5.  Patient and haemodynamic factors affecting intraoperative graft flow during coronary artery bypass grafting: an observational pilot study.

Authors:  Sang-Wook Lee; Jun-Young Jo; Wook-Jong Kim; Dae-Kee Choi; In-Cheol Choi
Journal:  Sci Rep       Date:  2020-07-31       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.