Nonuniform strut distribution correlates with more neointimal hyperplasia after sirolimus-eluting stent implantation.

Hideo Takebayashi1, Gary S Mintz, Stéphane G Carlier, Yoshio Kobayashi, Kenichi Fujii, Takenori Yasuda, Ricardo A Costa, Issam Moussa, George D Dangas, Roxana Mehran, Alexandra J Lansky, Edward Kreps, Michael B Collins, Antonio Colombo, Gregg W Stone, Martin B Leon, Jeffrey W Moses.   

Abstract

BACKGROUND: Little is known about causes of intimal hyperplasia (IH) after sirolimus-eluting stent (SES) implantation. METHODS AND
RESULTS: Intravascular ultrasound was performed in 24 lesions with intra-SES restenosis and a comparison group of 25 nonrestenotic SESs. To assess stent strut distribution, the maximum interstrut angle was measured with a protractor centered on the stent, and the visible struts were counted and normalized for the number of stent cells. In SES restenosis patients, minimum lumen site was compared with image slices 2.5, 5.0, 7.5, and 10.0 mm proximal and distal to this site. The minimum lumen site had a smaller IVUS lumen area at follow-up (2.7+/-0.9 versus 6.2+/-1.9 mm2; P<0.01), larger maximum interstrut angle (135+/-39 degrees versus 72+/-23 degrees; P<0.01), larger IH area (3.4+/-1.5 versus 0.6+/-1.1 mm2; P<0.01) and thickness (0.7+/-0.3 versus 0.1+/-0.2 mm; P<0.01) at maximum interstrut angle, and fewer stent struts (4.9+/-1.0 versus 6.0+/-0.5; P<0.01) even when normalized for the number of stent cells (0.78+/-0.15 versus 0.97+/-0.07; P<0.01). Compared with nonrestenotic SES, the restenosis lesions also had a smaller minimal lumen area, larger IH area, thicker IH at maximum interstrut angle, fewer stent struts, and larger maximum interstrut angle. Multivariate analysis identified the number of visualized stent struts normalized for the number of stent cells and maximum interstrut angle as the only independent IVUS predictor of IH cross-sectional area (P<0.01 and P<0.01), minimum lumen area (P<0.01 and P<0.01), and IH thickness (P<0.01 and P<0.01).
CONCLUSIONS: The number and distribution of stent struts affect the amount of neointima after SES implantation.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15557367     DOI: 10.1161/01.CIR.0000148371.53174.05

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  17 in total

1.  Long-term angiographic outcomes of post-sirolimus-eluting stent restenosis in Japanese patients.

Authors:  Nobuyuki Miyai; Noriyuki Kinoshita; Keisuke Oota; Takeshi Yamada; Reo Nakamura; Hidekazu Irie; Tetsuo Hashimoto; Shyunichi Tamaki; Hiroaki Matsubara
Journal:  Heart Vessels       Date:  2010-10-27       Impact factor: 2.037

Review 2.  Prediction of protein function and pathways in the genome era.

Authors:  T Gabaldón; M A Huynen
Journal:  Cell Mol Life Sci       Date:  2004-04       Impact factor: 9.261

3.  Main branch stent deformation following difficult side branch rewiring and balloon dilatation. Rare complication of provisional T stenting.

Authors:  M Tomasevic; V Vukcevic; G Stankovic; D Orlic; M Ostojic
Journal:  Herz       Date:  2010-09-22       Impact factor: 1.443

4.  Effect of intravascular ultrasound-guided adjuvant high-pressure non-compliant balloon post-dilation after drug-eluting stent implantation.

Authors:  Yoshitaka Muraoka; Shinjo Sonoda; Yuki Tsuda; Seiya Tanaka; Masahiro Okazaki; Yutaka Otsuji
Journal:  Heart Vessels       Date:  2010-12-23       Impact factor: 2.037

5.  Effect of strut distribution on neointimal coverage of everolimus-eluting bioresorbable scaffolds: an optical coherence tomography study.

Authors:  Takao Sato; John Jose; Abdelhakim Allai; Mohamed El-Mawardy; Ralph Tölg; Gert Richardt; Mohamed Abdel-Wahab
Journal:  J Thromb Thrombolysis       Date:  2017-08       Impact factor: 2.300

6.  Modeling and analysis of drug-eluting stents with biodegradable PLGA coating: consequences on intravascular drug delivery.

Authors:  Xiaoxiang Zhu; Richard D Braatz
Journal:  J Biomech Eng       Date:  2014-11       Impact factor: 2.097

Review 7.  Mechanisms of drug-eluting stent restenosis.

Authors:  Jiro Aoki; Kengo Tanabe
Journal:  Cardiovasc Interv Ther       Date:  2020-11-21

8.  Stent implant follow-up in intravascular optical coherence tomography images.

Authors:  Gozde Unal; Serhan Gurmeric; Stéphane Guy Carlier
Journal:  Int J Cardiovasc Imaging       Date:  2009-09-24       Impact factor: 2.357

9.  Comparisons of the effects of stent eccentricity on the neointimal hyperplasia between sirolimus-eluting stent versus paclitaxel-eluting stent.

Authors:  Byeong-Keuk Kim; Young-Guk Ko; Seungjin Oh; Jung-Sun Kim; Woong Chol Kang; Dong Woon Jeon; Joo Young Yang; Donghoon Choi; Myeong-Ki Hong; Taehoon Ahn; Yangsoo Jang
Journal:  Yonsei Med J       Date:  2010-11       Impact factor: 2.759

Review 10.  Intravascular foreign bodies: danger of unretrieved fragmented medical devices.

Authors:  Minori Tateishi; Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.