Literature DB >> 15553586

Factors affecting postoperative range of motion after total knee arthroplasty.

Nehal M Gatha1, Henry D Clarke, Robin Fuchs, Giles R Scuderi, John N Insall.   

Abstract

One hundred thirty five patients with osteoarthritis who underwent total knee arthroplasty (TKA) were evaluated to determine whether specific pre- and postoperative variables were correlated with the postoperative range of motion. Age, sex, pre- and postoperative range of motion, pre- and postoperative Knee Society scores, intraoperative patellar thickness before and after resurfacing, pre- and postoperative radiographic patellar height (as determined by the Insall-Salvati and Blackburn-Peel ratios), and preoperative radiographic alignment were recorded for each patient. Regression analysis was performed to identify whether any variables were correlated with the postoperative range of motion or Knee Society scores. The only variable that was significantly correlated with postoperative range of motion was the preoperative range of motion. This study suggests that among the variables evaluated, the preoperative range of motion was the only significant predictor of postoperative range of motion.

Entities:  

Mesh:

Year:  2004        PMID: 15553586     DOI: 10.1055/s-0030-1248221

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  33 in total

1.  Enhanced recovery programmes can reduce length of stay after total knee replacement without sacrificing functional outcome at one year.

Authors:  J F Maempel; P J Walmsley
Journal:  Ann R Coll Surg Engl       Date:  2015-10-13       Impact factor: 1.891

2.  Does TKA improve functional outcome and range of motion in patients with stiff knees?

Authors:  Young-Hoo Kim; Jun-Shik Kim
Journal:  Clin Orthop Relat Res       Date:  2008-08-20       Impact factor: 4.176

3.  Platelet-rich plasma prevents blood loss and pain and enhances early functional outcome after total knee arthroplasty: a prospective randomised controlled study.

Authors:  Aditya K Aggarwal; V S Shashikanth; Neelam Marwaha
Journal:  Int Orthop       Date:  2013-10-11       Impact factor: 3.075

4.  Total knee arthroplasty in stiff knee compared with flexible knees.

Authors:  M Fosco; M Filanti; L Amendola; L M Savarino; D Tigani
Journal:  Musculoskelet Surg       Date:  2011-03-09

5.  Prediction of range of motion 2 years after mobile-bearing total knee arthroplasty: PCL-retaining versus PCL-sacrificing.

Authors:  Yoshinori Ishii; Hideo Noguchi; Mitsuhiro Takeda; Junko Sato; Shin-ichi Toyabe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-02-03       Impact factor: 4.342

6.  Factors affecting range of motion after total knee arthroplasty in patients with more than 120 degrees of preoperative flexion angle.

Authors:  Kazuya Sugitani; Yuji Arai; Hisatake Takamiya; Ryu Terauchi; Shuji Nakagawa; Keiichiro Ueshima; Toshikazu Kubo
Journal:  Int Orthop       Date:  2015-02-27       Impact factor: 3.075

7.  Importance of knee flexion range of motion during the acute phase after total knee arthroplasty.

Authors:  Tomohiro Oka; Osamu Wada; Tsuyoshi Asai; Hideto Maruno; Kiyonori Mizuno
Journal:  Phys Ther Res       Date:  2020-08-05

8.  Does patellar eversion in total knee arthroplasty cause patella baja?

Authors:  Vineet Sharma; Panagiotis G Tsailas; Aditya V Maheshwari; Amar S Ranawat; Chitranjan S Ranawat
Journal:  Clin Orthop Relat Res       Date:  2008-06-21       Impact factor: 4.176

9.  Changes in femoral posterior condylar offset and knee flexion after PCL-substituting total knee arthroplasty: comparison of anterior and posterior referencing systems.

Authors:  Hyuksoo Han; Sohee Oh; Chong Bum Chang; Seung-Baik Kang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-14       Impact factor: 4.342

10.  Preoperative flexion does not influence postoperative flexion after rotating-platform total knee arthroplasty.

Authors:  Robert D Russell; Michael H Huo; Leslie de Jong; Richard E Jones
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-01-12       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.