Literature DB >> 15551575

Methods for fully automated verification of patient set-up in external beam radiotherapy with polygon shaped fields.

K Eilertsen1, A Skretting, T L Tennvassås.   

Abstract

Methods have been developed to perform fully automated comparisons of the radiotherapy simulator and portal images in the most common cases where the field edges consist of straight lines. The field defining wires or rods in the simulator image, and the edges of the portal image, are localized by means of a truncated Radon transform. Edges are enhanced with the use of a generalized Laplacian operator. From the detected field outlines, a geometrical mapping function is determined that rotates, scales, and translates one image with respect to the other. A subsequent match of field shapes is executed. If satisfactory agreement is established, the anatomical structures of the simulator and portal images are compared by correlating a new pair of images that only contain the intensity ridges representing bone outlines. The correlation determines the rotation and translation that must be applied to align the anatomical structures. With the simulator image already processed, the remaining automatic processing takes approximately 2 min on a SUN Sparcstation 2. By use of a priori knowledge of the fields, the computation time needed after acquisition of the portal image may be reduced to about 40 s for 512 x 512 images and about 12 s for 256 x 256 images.

Entities:  

Mesh:

Year:  1994        PMID: 15551575     DOI: 10.1088/0031-9155/39/6/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Automated 2D-3D registration of a radiograph and a cone beam CT using line-segment enhancement.

Authors:  Reshma Munbodh; David A Jaffray; Douglas J Moseley; Zhe Chen; Jonathan P S Knisely; Pascal Cathier; James S Duncan
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

2.  A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy.

Authors:  Reshma Munbodh; Zhe Chen; David A Jaffray; Douglas J Moseley; Jonathan P S Knisely; James S Duncan
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

3.  Automated 2D-3D registration of portal images and CT data using line-segment enhancement.

Authors:  Reshma Munbodh; Zhe Chen; David A Jaffray; Douglas J Moseley; Jonathan P S Knisely; James S Duncan
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

4.  Accuracy of an automatic patient-positioning system based on the correlation of two edge images in radiotherapy.

Authors:  Myonggeun Yoon; Minho Cheong; Jinsung Kim; Dong Ho Shin; Sung Yong Park; Se Byeong Lee
Journal:  J Digit Imaging       Date:  2010-02-02       Impact factor: 4.056

5.  Assessment of pulmonary 18F-FDG-PET uptake and cytokine profiles in non-small cell lung cancer patients treated with radiotherapy and erlotinib.

Authors:  Azadeh Abravan; Hanne Astrid Eide; Ingerid Skjei Knudtsen; Ayca Muftuler Løndalen; Åslaug Helland; Eirik Malinen
Journal:  Clin Transl Radiat Oncol       Date:  2017-06-15
  5 in total