Literature DB >> 15541673

AcroFlex design and results.

Robert D Fraser1, E Raymond Ross, Gary L Lowery, Brian J Freeman, Mark Dolan.   

Abstract

The AcroFlex prosthesis is unique when compared to other current devices, as it has an elastomeric core sandwiched between two titanium endplates. The purpose of this design was to optimize shock absorption qualities. This paper reviews the design of the AcroFlex Disc and relevant design and outcomes of two pilot studies carried out on 28 patients using the AcroFlex prosthesis. Although clinical outcomes of the pilot studies were successful, the pivotal randomized trial has not been carried out due to detection of mechanical failure of the elastomer on thin cut CT scans. The implications of this for the AcroFlex and other arthroplasties are discussed.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15541673     DOI: 10.1016/j.spinee.2004.07.020

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  20 in total

Review 1.  Cervical and lumbar spinal arthroplasty: clinical review.

Authors:  T D Uschold; D Fusco; R Germain; L M Tumialan; S W Chang
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

Review 2.  Design concepts in lumbar total disc arthroplasty.

Authors:  Fabio Galbusera; Chiara M Bellini; Thomas Zweig; Stephen Ferguson; Manuela T Raimondi; Claudio Lamartina; Marco Brayda-Bruno; Maurizio Fornari
Journal:  Eur Spine J       Date:  2008-10-23       Impact factor: 3.134

3.  Influence of preoperative leg pain and radiculopathy on outcomes in mono-segmental lumbar total disc replacement: results from a nationwide registry.

Authors:  Thomas Zweig; Emin Aghayev; Markus Melloh; Daniel Dietrich; Christoph Röder
Journal:  Eur Spine J       Date:  2011-06-10       Impact factor: 3.134

4.  Influence of preoperative nucleus pulposus status and radiculopathy on outcomes in mono-segmental lumbar total disc replacement: results from a nationwide registry.

Authors:  Thomas Zweig; Christoph Hemmeler; Emin Aghayev; Markus Melloh; Christian Etter; Christoph Röder
Journal:  BMC Musculoskelet Disord       Date:  2011-12-02       Impact factor: 2.362

5.  Submicron sized ultra-high molecular weight polyethylene wear particle analysis from revised SB Charité III total disc replacements.

Authors:  Ilona Punt; Ryan Baxter; André van Ooij; Paul Willems; Lodewijk van Rhijn; Steven Kurtz; Marla Steinbeck
Journal:  Acta Biomater       Date:  2011-05-20       Impact factor: 8.947

6.  Long-term outcome after implantation of prosthetic disc nucleus device (PDN) in lumbar disc disease.

Authors:  P Selviaridis; N Foroglou; A Tsitlakidis; A Hatzisotiriou; I Magras; I Patsalas
Journal:  Hippokratia       Date:  2010-07       Impact factor: 0.471

7.  Are periprosthetic tissue reactions observed after revision of total disc replacement comparable to the reactions observed after total hip or knee revision surgery?

Authors:  Ilona M Punt; Shennah Austen; Jack P M Cleutjens; Steven M Kurtz; René H M ten Broeke; Lodewijk W van Rhijn; Paul C Willems; André van Ooij
Journal:  Spine (Phila Pa 1976)       Date:  2012-01-15       Impact factor: 3.468

Review 8.  Total disc replacement in the lumbar spine: a systematic review of the literature.

Authors:  Brian J C Freeman; James Davenport
Journal:  Eur Spine J       Date:  2006-07-22       Impact factor: 3.134

9.  We Need to Talk about Lumbar Total Disc Replacement.

Authors:  Stephen Beatty
Journal:  Int J Spine Surg       Date:  2018-08-03

10.  The LP-ESP(®) lumbar disc prosthesis with 6 degrees of freedom: development and 7 years of clinical experience.

Authors:  Jean-Yves Lazennec; Alain Aaron; Adrien Brusson; Jean-Patrick Rakover; Marc-Antoine Rousseau
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-01-11
View more