Submicron sized ultra-high molecular weight polyethylene wear particle analysis from revised SB Charité III total disc replacements.

Ilona Punt1, Ryan Baxter, André van Ooij, Paul Willems, Lodewijk van Rhijn, Steven Kurtz, Marla Steinbeck.   

Abstract

Submicron sized particles are frequently observed in retrieved total hip and knee periprosthetic tissues and appear to be critical in the activation of the phagocytic inflammatory response. In this paper the concentration, size and shape of ultra-high molecular weight polyethylene (UHMWPE) wear particles between 0.05 and 2.00μm were determined after isolation from periprosthetic tissues from retrieved lumbar SB Charité III total disc replacements (TDR) using scanning electron microscopy (SEM). For comparison, UHMWPE wear particles were isolated from γ-radiation-air sterilized total hip arthroplasty (THA) revision tissues. The mean concentration of UHMWPE particles in TDR tissues was 1.6×10(9)g(-1)tissue (range 1.3-2.0), which was significantly lower than the concentration of 2.3×10(9)g(-1) THA revision tissue (range 1.8-3.2) (P=0.03). The mean particle size (equivalent circular diameter: TDR, 0.46μm; THA 0.53μm, P=0.60) and mean shape were comparable between TDR and THA (aspect ratio: TDR, 1.89; THA, 1.99, P=0.35; roundness: TDR, 0.58; THA, 0.56, P=0.35). However, the TDR particles tended to be smaller and more round. Although no correlations were found between visible damage to the UHMWPE core and the concentration or shape of the UHMWPE particles, a positive correlation was found between increasing particle size and increasing rim penetration of the TDR core (P=0.04). The presence of UHMWPE particles of similar size and shape in TDR tissue, albeit lower in concentration, might explain why, unlike THA, pain rather than osteolysis is the major reason for revision surgery.
Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21621656      PMCID: PMC3148413          DOI: 10.1016/j.actbio.2011.05.010

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  47 in total

1.  Debris from failed ceramic-on-ceramic and ceramic-on-polyethylene hip prostheses.

Authors:  Y Mochida; M Boehler; M Salzer; T W Bauer
Journal:  Clin Orthop Relat Res       Date:  2001-08       Impact factor: 4.176

2.  Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles.

Authors:  H G Willert; H Bertram; G H Buchhorn
Journal:  Clin Orthop Relat Res       Date:  1990-09       Impact factor: 4.176

3.  Composition and morphology of wear debris in failed uncemented total hip replacement.

Authors:  A S Shanbhag; J J Jacobs; T T Glant; J L Gilbert; J Black; J O Galante
Journal:  J Bone Joint Surg Br       Date:  1994-01

4.  A meta-analysis of artificial total disc replacement versus fusion for lumbar degenerative disc disease.

Authors:  Wu Yajun; Zhu Yue; Han Xiuxin; Cui Cui
Journal:  Eur Spine J       Date:  2010-04-04       Impact factor: 3.134

5.  Polyethylene wear and rim fracture in total disc arthroplasty.

Authors:  Steven M Kurtz; André van Ooij; Raymond Ross; Jan de Waal Malefijt; John Peloza; Lauren Ciccarelli; Marta L Villarraga
Journal:  Spine J       Date:  2006-12-06       Impact factor: 4.166

6.  Risk factors for adjacent-segment failure following lumbar fixation with rigid instrumentation for degenerative instability.

Authors:  S Etebar; D W Cahill
Journal:  J Neurosurg       Date:  1999-04       Impact factor: 5.115

7.  Radio-opaque agents in bone cement increase bone resorption.

Authors:  A Sabokbar; Y Fujikawa; D W Murray; N A Athanasou
Journal:  J Bone Joint Surg Br       Date:  1997-01

8.  Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro.

Authors:  T R Green; J Fisher; M Stone; B M Wroblewski; E Ingham
Journal:  Biomaterials       Date:  1998-12       Impact factor: 12.479

9.  Comparison and quantitation of wear debris of failed total hip and total knee arthroplasty.

Authors:  K Hirakawa; T W Bauer; B N Stulberg; A H Wilde
Journal:  J Biomed Mater Res       Date:  1996-06

Review 10.  Total disc replacement surgery for symptomatic degenerative lumbar disc disease: a systematic review of the literature.

Authors:  Karin D van den Eerenbeemt; Raymond W Ostelo; Barend J van Royen; Wilco C Peul; Maurits W van Tulder
Journal:  Eur Spine J       Date:  2010-05-28       Impact factor: 3.134

View more
  10 in total

1.  UHMWPE wear debris and tissue reactions are reduced for contemporary designs of lumbar total disc replacements.

Authors:  Sai Y Veruva; Todd H Lanman; Jorge E Isaza; Daniel W MacDonald; Steven M Kurtz; Marla J Steinbeck
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

Review 2.  Which design and biomaterial factors affect clinical wear performance of total disc replacements? A systematic review.

Authors:  Sai Y Veruva; Marla J Steinbeck; Jeffrey Toth; Dominik D Alexander; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

3.  Periprosthetic UHMWPE Wear Debris Induces Inflammation, Vascularization, and Innervation After Total Disc Replacement in the Lumbar Spine.

Authors:  Sai Y Veruva; Todd H Lanman; Jorge E Isaza; Theresa A Freeman; Steven M Kurtz; Marla J Steinbeck
Journal:  Clin Orthop Relat Res       Date:  2017-05       Impact factor: 4.176

4.  Clinical, radiological, histological and retrieval findings of Activ-L and Mobidisc total disc replacements: a study of two patients.

Authors:  Shennah Austen; Ilona M Punt; Jack P M Cleutjens; Paul C Willems; Steven M Kurtz; Daniel W MacDonald; Lodewijk W van Rhijn; André van Ooij
Journal:  Eur Spine J       Date:  2012-01-15       Impact factor: 3.134

5.  The Latest Lessons Learned from Retrieval Analyses of Ultra-High Molecular Weight Polyethylene, Metal-on-Metal, and Alternative Bearing Total Disc Replacements.

Authors:  Steven M Kurtz; Jeffrey M Toth; Ryan Siskey; Lauren Ciccarelli; Dan Macdonald; Jorge Isaza; Todd Lanman; Ilona Punt; Marla Steinbeck; Jan Goffin; André van Ooij
Journal:  Semin Spine Surg       Date:  2012-03-01

6.  Severe impingement of lumbar disc replacements increases the functional biological activity of polyethylene wear debris.

Authors:  Ryan M Baxter; Daniel W Macdonald; Steven M Kurtz; Marla J Steinbeck
Journal:  J Bone Joint Surg Am       Date:  2013-06-05       Impact factor: 5.284

7.  We Need to Talk about Lumbar Total Disc Replacement.

Authors:  Stephen Beatty
Journal:  Int J Spine Surg       Date:  2018-08-03

8.  ISASS Policy Statement - Lumbar Artificial Disc.

Authors:  Jack Zigler; Rolando Garcia
Journal:  Int J Spine Surg       Date:  2015-03-12

Review 9.  Material Science in Cervical Total Disc Replacement.

Authors:  Martin H Pham; Vivek A Mehta; Alexander Tuchman; Patrick C Hsieh
Journal:  Biomed Res Int       Date:  2015-10-07       Impact factor: 3.411

10.  Wear characteristics of an unconstrained lumbar total disc replacement under a range of in vitro test conditions.

Authors:  Philip J Hyde; John Fisher; Richard M Hall
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-09-28       Impact factor: 3.368

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.